How To
|
Canned Action Plan (CAP) Documents
|
Last Modified Date
|
2305633.1 |
How to Perform a Pre-PM Task for Exadata, Exalogic, SuperCluster, or BDA |
2017-09-08
|
1997443.1 |
How to Replace an Exadata Compute/Storage Node Power Supply Unit |
2016-01-20
|
1681165.1 |
How to Replace a Faulty ESM on a Flash F20 or F20M2 card in an Exadata Storage Server (V2/X2-2/X2-8) [VCAP] |
2018-04-10
|
1681141.1 |
How to Replace a Faulty Flash F20 or F20M2 card in an Exadata Storage Server (V2/X2-2/X2-8) |
2018-04-10
|
1531225.1 |
How to Replace an Avocent KVM switch in an Engineered Systems rack |
2017-10-18
|
1531203.1 |
How to Replace a Cisco ethernet switch in an Engineered Systems rack [VCAP] |
2017-08-22
|
1527626.1 |
How to Replace a HBA Battery Backup Unit (BBU) on Exadata Database Machine (V2, X2-2, X2-8) [VCAP] |
2017-07-07
|
1524308.1 |
How to Replace the internal USB Recovery Drive on an Exadata Storage Server (prior to X5-2L) |
2018-04-10
|
1479736.1 |
How to Replace an Exadata Compute (Database) node hard disk drive (Predictive or Hard Failure) (X4-2 and earlier) |
2017-04-03
|
1446404.1 |
How to Replace a Failed InfiniBand (HCA) Card on a V2/X2-2/X2-8 Exadata Storage Server or V2/X2-2 Compute Node |
2018-04-08
|
1444683.1 |
How to replace and install cables in a Cable Management Arm (CMA) in Engineered Systems Racks [VCAP] |
2017-06-02
|
1423708.1 |
Replacement procedure for How to Replace a Power Distribution Unit on an Engineered System using Sun Rack II |
2017-07-26
|
1390836.1 |
How to Replace a Hard Drive in an Exadata Storage Server (Predictive Failure) |
2018-04-30
|
1388322.1 |
How to Replace a Faulty RAID HBA on an Exadata server (V2 - X4-2/X4-8) |
2017-04-14
|
1386147.1 |
How to Replace a Hard Drive in an Exadata Storage Server (Hard Failure) |
2018-05-15
|
1381209.1 |
How to Replace a Faulty FMOD on a Flash F20 or F20M2 card in an Exadata Storage Server (V2/X2-2/X2-8) |
2018-04-10
|
1377637.1 |
How to replace a Power Distribution Unit (PDU) on an Engineered System using Sun Rack II |
2016-12-07
|
1356473.1 |
How to Perform Exadata or SuperCluster Preventive Maintenance Service |
2017-10-27
|
1347649.1 |
How to Replace a Sun Fire X4170, X4270 DVD/USB Module |
2018-05-23
|
1347635.1 |
How to Replace a Sun Fire X4170, X4270 Coin Cell Battery |
2018-05-23
|
1347606.1 |
How to Replace a Sun Fire X4170, X4270, X4275 PCIe Riser Card |
2018-05-21
|
1347358.1 |
How to Replace a Sun Fire X4170, X4270 Disk Backplane |
2018-05-23
|
1347357.1 |
How to Replace a Sun Fire X4170, X4270 Light Pipe Assembly |
2018-05-23
|
1347331.1 |
How to Replace a Sun Fire X4170, X4270 Connector Board (Paddle Card) |
2018-05-24
|
1347327.1 |
How to Replace a Sun Fire X4170, X4270 CPU |
2018-05-24
|
1347320.1 |
How to Replace a Sun Fire X4170, X4270 Fan Board |
2018-05-24
|
1347311.1 |
How to Replace a Sun Fire X4170, X4270 Fan Module |
2018-05-24
|
1347293.1 |
How to Replace a Sun Fire X4170, X4270 Internal SAS Cable |
2018-05-24
|
1347283.1 |
How to Replace a Sun Fire X4170, X4270 Memory DIMM |
2018-05-24
|
1347280.1 |
How to Replace a Sun Fire X4170, X4270 Power Distribution Board Ribbon Cable |
2018-05-24
|
1347273.1 |
How to Replace a Sun Fire X4170 Power Distribution Board |
2018-05-09
|
1347232.1 |
How to Replace a Sun Fire X4170, X4270 Power Supply |
2018-05-24
|
1341658.1 |
How to Replace a Failed Sun Datacenter InfiniBand Switch 36 |
2018-05-09
|
1336083.1 |
How to Replace a Motherboard on a Server that is part of an Exadata Database Machine |
2016-01-20
|
1332545.1 |
How to Replace a Sun Fire X4275 Cable Kit |
2018-05-21
|
1332334.1 |
How to Replace a Sun Fire X4275 SAS Expander Card |
2018-05-21
|
1332324.1 |
How to Replace a Sun Fire X4275 Internal SAS Cable |
2018-05-21
|
1332313.1 |
How to Replace a Sun Fire X4275 Coin Cell Battery |
2018-05-21
|
1332307.1 |
How to Replace a Sun Fire X4275 Disk Backplane |
2018-05-21
|
1332249.1 |
How to Replace a Sun Fire X4275 Power Distribution Board |
2018-05-21
|
1332244.1 |
How to Replace a Sun Fire X4275 Power Supply |
2018-05-21
|
1332237.1 |
How to Replace a Sun Fire X4275 Memory DIMM |
2018-05-21
|
1332236.1 |
How to Replace a Sun Fire X4275 Power Distribution Board Ribbon Cable |
2018-05-21
|
1332227.1 |
How to Replace a Sun fire X4275 Fan Module |
2018-05-22
|
1332162.1 |
How to Replace a Sun Fire X4275 CPU |
2018-05-22
|
1319306.1 |
How to Replace a Sun Fire X4275 Connector Board |
2018-05-22
|
1319296.1 |
How to Replace a Sun Fire X4275 Fan Board |
2018-05-22
|
How To
|
Non CAP Knowledge Documents
|
Last Modified Date
|
2367609.1 |
How to Shutdown and Startup Exadata database nodes running OVM |
2018-03-28
|
2238622.1 |
IB SWITCH:Engineered Systems : Unable To Create User Account In IB Switches |
2018-01-03
|
2186095.1 |
Additional Solaris OS Steps for installation of 12.2.0.1 Grid Infrastructure and Database Upgrade on Oracle Solaris Operating System on Exadata Database Machine or Oracle SuperCluster running 11.2.0.3 or later |
2017-05-02
|
2160289.1 |
How To - Exadata - Configure YUM to connect to Oracle Public Repository |
2018-05-23
|
2125203.1 |
Infiniband Switch Replacement - Follow-up Actions |
2018-04-08
|
2103715.1 |
Engineered Systems ASR Configuration Check tool (asrexacheck version 4.x) |
2017-07-19
|
2088888.1 |
How to Update Disk Drive Firmware on Exadata and Recovery Appliance Compute Nodes |
2016-04-19
|
1947114.1 |
How to boot Exadata database server with diagnostic ISO image |
2016-05-29
|
1919941.1 |
11.2.0.4 Grid Infrastructure and Database Upgrade on Exadata Database Machine running Oracle Solaris and Oracle SuperCluster |
2016-07-29
|
1908556.1 |
11.2.0.2, 11.2.0.3, 11.2.0.4 or 12.1.0.1 to 12.1.0.2 Grid Infrastructure and Database Upgrade on Exadata Database Machine running Oracle Solaris and Solaris Supercluster |
2016-07-29
|
1675774.1 |
Case Studies - dbnodeupdate.sh incomplete execution |
2014-05-27
|
1610695.1 |
How to make Offline Voting Disk to Online in Exadata ? |
2016-09-12
|
1608918.1 |
How to generate a DCLI Group file for, and collect diagnostics on, Exadata or SuperCluster IB Switches. |
2014-01-15
|
1605483.1 |
How to determine Exadata DB or Storage Cell node location within a single or multi-rack configuration using the node name |
2014-04-25
|
1593004.1 |
How To Update Exadata Management Network Switch Firmware |
2015-08-20
|
1586212.1 |
How to Change MTU Size in Exadata Environment |
2016-11-09
|
1584924.1 |
Is LDAP authentication supported on Exadata and ODA (Oracle Database Appliance)? |
2016-03-08
|
1580584.1 |
Setup Listener on Infiniband Network using both SDP and TCP Protocol |
2016-08-08
|
1576819.1 |
Is it possible to run Exachk on the management network? |
2013-09-23
|
1543162.1 |
How to Identify and Diagnose Fan Failures on Sun SPARC Enterprise T5120/T5140/T5220/T5240/T5440 and Netra T5220/T5440 |
2017-12-21
|
1534482.1 |
Upgrading to Solaris 11.1 on Solaris x86-64 Exadata Compute nodes |
2014-10-13
|
1524329.1 |
Root Volume of Predictive Failure Boot Hard Drive in an Exadata Storage Server Remains in State of 'active' |
2013-04-11
|
1519705.1 |
Support of HCC on other environments than Exadata |
2013-01-22
|
1485882.1 |
After disk replacement cell disk name is appearing like "%_duplicate_%" and list griddisk status is showing "importRequired" |
2016-06-06
|
1485856.1 |
Exadata Hardening Breaks the Exadata Backup Tool Scripts |
2013-01-18
|
1468364.1 |
Exadata - How to Change interconnect bonding interface on the compute nodes |
2017-03-02
|
1465038.1 |
Calculating Usable Space in Exadata Cell |
2012-09-27
|
1455819.1 |
How to set up a temporary alert from a cell which does more than "alter cell validate mail" |
2012-06-18
|
1448316.1 |
Exachk returns MaxStartups parameter in /etc/ssh/sshd_config should set to recommended value |
2012-05-24
|
1433903.1 |
U-Boot Diagnostics on Oracle X86-based Systems |
2018-04-18
|
1358018.1 |
PDUs are unavailable via web browser |
2013-07-31
|
1353507.1 |
Enable outbound Sendmail on Linux |
2012-05-23
|
1341944.1 |
How To Back Up and Restore Switch Settings for Sun Datacenter InfiniBand Switch 36 & Gateway Switch |
2018-04-04
|
1281395.1 |
Steps to manually create cell/grid disks on Exadata if auto-create fails during disk replacement |
2017-07-03
|