Asset ID: |
1-71-1347293.1 |
Update Date: | 2018-05-24 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347293.1
:
How to Replace a Sun Fire X4170, X4270 Internal SAS Cable
Related Items |
- Sun Fire X4270 Server
- Sun Fire X4170 Server
- Exadata Database Machine V2
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4170 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire X4270 Server - Version Not Applicable to Not Applicable [Release N/A]
Exadata Database Machine V2 - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4170, X4270 Internal SAS Cable.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 180 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4170, X4270 Internal SAS Cable needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
The customer should conduct an orderly software system shutdown.
A data backup is not a pre-requisite but is a wise precaution.
Note: If this server is part of an Exadata, please follow shutdown instructions in Section 1 of DOC ID:
1539451.1
Then power down the system and disconnect the Power Cord.
WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server and disconnect the power cord (or cords) from the power supply (or supplies).
2. Slide the server out of the rack.
3. Remove the top cover.
4. Untwist the cable tie downs to release the SAS cable(s).
5. To disconnect the cables from the host bus adapter (HBA) PCIe card, depress the latch, push in toward the connector, and then pull out to remove the cable(s).
6. To disconnect each cable at the storage drive backplane, press the latch, push in toward the connector, and then pull out to remove the cable.
Note ! Removing the cable might be made easier by removing one or more fan modules first.
7. Remove the cables from the chassis.
Re-Install in X4170
1. To reinstall SAS cables 0-3 and 4-7 in a SunFire X4170 Server install the disk 0-3 cable first. This connector is on the left from the front of the unit.
2. Route the cable down and in front of the fan board(s), to prevent the cable from blocking the airflow.
Route the cable through the opening in the midwall, opposite the other disk backplane connector.
3. Plug the cable connector into the connector on the HBA card that is closest to the gold fingers (port 0).
4. Now install the disk 4-7 cable.
5. Plug the backplane connector(s) into the storage drive backplane.
6. Plug the cable connector into the connector on the HBA card that is farthest to the gold fingers (port 1).
7. Press the cables in the cable tie downs, and then secure the cable tie downs.
8. Re-install the fans
Re-Install in X4270
1. Install the cable connector into the storage drive backplane.
The connector is on the right from the front of the unit.
2. Route the cable down and in front of the fan board to prevent the cable from blocking the airflow.
Route the cable through the opening in the midwall, opposite the other disk backplane connector.
3. Plug the cable connector into the connector closest to the gold fingers (port 0) on the HBA card.
4. Re-install the fans
1. Install the top cover.
2. Install the server into the rack.
3. Power on
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Check for full system functionality
Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID:
1539451.1
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X4170, X4270, and X4275 Servers Service Manual
http://download.oracle.com/docs/cd/E19477-01/820-5830-13/index.html
How to shutdown the Exadata database nodes and storage cells in a rolling fashion so certain hardware tasks can be performed. (Doc ID 1539451.1)
Attachments
This solution has no attachment