Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1347649.1
Update Date:2018-05-23
Keywords:

Solution Type  Technical Instruction Sure

Solution  1347649.1 :   How to Replace a Sun Fire X4170, X4270 DVD/USB Module  


Related Items
  • Sun Fire X4270 Server
  •  
  • Sun Fire X4170 Server
  •  
  • Exadata Database Machine V2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
References


Applies to:

Sun Fire X4270 Server - Version Not Applicable to Not Applicable [Release N/A]
Sun Fire X4170 Server - Version Not Applicable to Not Applicable [Release N/A]
Exadata Database Machine V2 - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4170, X4270 DVD/USB Module.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4170, X4270 DVD/USB Module needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

(Note, if the x86 server is part of an Exadata V2 Engineered System, there is no DVD.  In that case, this document would only pertain to the USB device on the x86 server).

The customer should conduct an orderly software system shutdown.

A data backup is not a pre-requisite but is a wise precaution.

Note: If this server is part of an Exadata, please follow shutdown instructions in Section 1 of DOC ID: 1539451.1


- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Remove media from the drive

2. Powering off the system

3. Remove the disk drive located under-right position of the DVD drive (HDD7 for X4170, HDD13 for X4270)

4. Remove the DVD drive from the storage drive cage

5. Install new DVD drive into the storage drive cage

6. Powering on the system

OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:

Check for full system functionality

Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID: 1539451.1


PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX4170/components.html#RemovableMedia
https://support.oracle.com/handbook_private/Systems/SunFireX4270/components.html#RemovableMedia

REFERENCE INFORMATION:
Sun Fire X4170, X4270, and X4275 Servers Service Manual
http://download.oracle.com/docs/cd/E19477-01/820-5830-13/index.html

How to shutdown the Exadata database nodes and storage cells in a rolling fashion so certain hardware tasks can be performed. (Doc ID 1539451.1)


Attachments
This solution has no attachment