Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1332244.1
Update Date:2018-05-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  1332244.1 :   How to Replace a Sun Fire X4275 Power Supply  


Related Items
  • Sun Fire X4275 Server
  •  
  • Exadata Database Machine V2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution


Applies to:

Sun Fire X4275 Server - Version Not Applicable and later
Exadata Database Machine V2 - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4275 Power Supply.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 15 minutes

TASK COMPLEXITY: 0

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4275 Power Supply needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Then power down the system and disconnect the Power Cord.

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Identify which power supply(0 or 1) requires replacement
2. Gain access to the rear of the server where the faulty power supply is located
3. Release the cable management arm(CMA)
- Press and hold the tab
- Rotate the CMA out of the way so that you can access the power supply
4. Disconnect the power cord from the faulty power supply
5. Grasp the power supply handle and move the power supply latch to the right
6. Pull the power supply out of the chassis
7. Align the replacement power supply with the empty power supply chassis bay
8. Slide the power supply into the bay until it is fully seated
9. Reconnect the power cord to the power supply
10.Close the CMA, inserting the end of the CMA into the rear left rail bracket
11.Verify that the Service Action Required LED, the Front Service Action Required LED
and the Rear Service Action Required LED are not lit

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:

PARTS NOTE:

REFERENCE INFORMATION:

Sun Fire X4170, X4270, and X4275 Servers Service Manual
http://download.oracle.com/docs/cd/E19871-01/820-5830-13/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback