How to Replace a Sun Fire X4170, X4270 Power Supply
Related Items |
- Exadata Database Machine V2
- Sun Fire X4170 Server
- Sun Fire X4270 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4170 Server - Version All Versions to Not Applicable [Release All Releases to N/A]
Sun Fire X4270 Server - Version All Versions to All Versions [Release All Releases]
Exadata Database Machine V2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4170, X4270 Power Supply.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 30 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4170, X4270 Power Supply needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
Then power down the system and disconnect the Power Cord
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Identify which power supply(0 or 1) requires replacement
2. Gain access to the rear of the server where the faulty power supply is located
3. Release the cable management arm(CMA)
- Press and hold the tab
- Rotate the CMA out of the way so that you can access the power supply
4. Disconnect the power cord from the faulty power supply
5. Grasp the power supply handle and move the power supply latch to the right
6. Pull the power supply out of the chassis
7. Align the replacement power supply with the empty power supply chassis bay
8. Slide the power supply into the bay until it is fully seated
9. Reconnect the power cord to the power supply
10.Close the CMA, inserting the end of the CMA into the rear left rail bracket
11.Verify that the Service Action Required LED, the Front Service Action Required LED
and the Rear Service Action Required LED are not lit
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX4170/components.html#Power
REFERENCE INFORMATION: