Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1332324.1
Update Date:2018-05-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  1332324.1 :   How to Replace a Sun Fire X4275 Internal SAS Cable  


Related Items
  • Sun Fire X4275 Server
  •  
  • Exadata Database Machine V2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: fru cap

Applies to:

Sun Fire X4275 Server - Version Not Applicable and later
Exadata Database Machine V2 - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4275 Internal SAS Cable.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4275 Training

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4275 Internal SAS Cable needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Then power down the system and disconnect the Power Cord.

Note: If this server is part of an Exadata, please follow shutdown instructions in DOC ID: 1188080.1


WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Power off the server and disconnect the power cord (or cords) from the power supply (or supplies).
2. Slide the server out of the rack.
3. Remove the top cover.
4. Untwist the cable tie downs to release the SAS cable(s).
5. To disconnect the cables from the host bus adapter (HBA) PCIe card, depress the latch, push in toward the connector, and then pull out to remove the cable(s).
Note ! Take note of which connector the cable is connected to.
6. Disconnect the SAS cable from the disk drive cage disk expander card
a. To gain access to the disk expander card, remove the fan power board.
b. Remove the disk expander card and disconnect the SAS cable.
7. Remove the cable.

Re-Install in X4275
1. Install the cable in the disk expander card.
2. Install the disk expander card.
3. Install the fan power board.
4. Route the cable down beside the fan power board on the right side facing the server front panel to prevent the cable from blocking the airflow.
5. Install the fan modules.
6. Plug the cable connector into the connector on the HBA card from which the SAS cable was removed.
7. Press the cables in the cable tie down and secure the cable with the tie down.

1. Install the top cover.
2. Install the server into the rack.
3. Power on

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Check for full system functionality

Note: If this server is part of an Exadata, please follow restart instructions in step 7 of DOC ID: 1188080.1


PARTS NOTE:
None

REFERENCE INFORMATION:

Sun Fire X4170, X4270, and X4275 Servers Service Manual
http://download.oracle.com/docs/cd/E19871-01/820-5830-13/index.html

Steps to shut down or reboot an Exadata storage cell without affecting ASM (Doc ID 1188080.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback