How to Replace a Sun Fire X4170, X4270, X4275 PCIe Riser Card
Related Items |
- Sun Fire X4270 Server
- Sun Fire X4170 Server
- Sun Fire X4275 Server
- Exadata Database Machine V2
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Applies to:
Sun Fire X4170 Server - Version All Versions and later
Sun Fire X4270 Server - Version All Versions and later
Sun Fire X4275 Server - Version All Versions and later
Exadata Database Machine V2 - Version All Versions and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4170, X4270, X4275 PCIe Riser Card.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 45 minutes
TASK COMPLEXITY: 0
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4170, X4270, X4275 PCIe Riser Card needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
A data backup is not a pre-requisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.
Note: Please refer to DOC ID:
1539451.1 for instructions to shutdown a database node or DOC ID:
1188080.1 for instructions to shutdown a storage cell.
Then power down the system and disconnect the Power Cord.
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
1. Power off the server and disconnect the power cord (or cords) from the power supply (or supplies).
2. Slide the server out of the rack.
3. Remove the top cover.
4. Disconnect any data cables connected to the PCIe card on the PCIe riser being removed.
Note ! Label the cables to ensure proper connection later.
5. Remove the back panel crossbar
6. Disconnect any internal cables connected to the PCIe card installed in the riser
Note ! Label the cables to ensure proper connection later.
7. Loosen the captive Phillips screw on the end of the riser
8. Lift up the riser and the PCIe card attached to it, if any, as a unit and place on an anti-static mat
9. Transfer the PCIe card to the new PCI riser card
Installation is the reverse of the above procedure
1. Install the top cover.
2. Install the server into the rack.
3. Power on
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Check for full system functionality
Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID:
1539451.1 for a database node or instructions in step 7 of DOC ID:
1188080.1 for a storage cell.
PARTS NOTE:
https://support.oracle.com/handbook_private/Systems/SunFireX4170/components.html
https://support.oracle.com/handbook_private/Systems/SunFireX4270/components.html
https://mosemp.us.oracle.com/handbook_internal/Systems/SunFireX4275/components.html
REFERENCE INFORMATION:
Sun Fire X4170, X4270, and X4275 Servers Service Manual
http://download.oracle.com/docs/cd/E19477-01/820-5830-13/index.html
How to shutdown the Exadata database nodes and storage cells in a rolling fashion so certain hardware tasks can be performed. (Doc ID 1539451.1)
Steps to shut down or reboot an Exadata storage cell without affecting ASM (Doc ID 1188080.1)
Attachments
This solution has no attachment