Asset ID: |
1-71-1347357.1 |
Update Date: | 2018-05-23 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
1347357.1
:
How to Replace a Sun Fire X4170, X4270 Light Pipe Assembly
Related Items |
- Sun Fire X4170 Server
- Sun Fire X4270 Server
- Exadata Database Machine V2
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP
Applies to:
Exadata Database Machine V2 - Version All Versions and later
Sun Fire X4270 Server - Version Not Applicable and later
Sun Fire X4170 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Replace a Sun Fire X4170, X4270 Light Pipe Assembly.
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4170, X4270 Training
TIME ESTIMATE: 60 minutes
TASK COMPLEXITY: 1
FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: A Sun Fire X4170, X4270 Light Pipe Assembly needs replacement
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
If the system is still up and functioning, customer should perform an orderly and graceful shutdown of applications and OS.
A data backup is not a pre-requisite but is a wise precaution.
Note: If this server is part of an Exadata, please follow shutdown instructions in Section 1 of DOC ID:
1539451.1
- WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
Remove the light pipe assembly:
- Prepare the server for service.
- Power off the server and disconnect the power cord (or cords) from the power supply (or supplies)
- Slide the server out of the rack
- Attach an antistatic wrist strap
- Remove the top cover
- Remove the storage drive cage
- Remove the storage drive backplane
- Do one of the following:
- For the Sun Fire X4170 Server, remove the two No. 2 Phillips screws securing the front control panel light pipe assembly to the storage drive cage
- For the Sun Fire X4270 Server, remove the three No. 2 Phillips screws securing the front control panel light pipe assembly to the storage drive cage
- Slide the light pipe assembly out of the storage drive cage
Install the light pipe assembly:
- Align the light pipe assembly with the mounting holes on the storage drive cage
- Secure the light pipe assembly with the No. 2 Phillips screws
- Install the storage drive backplane
- Install the storage drive cage
- Return the server to operation:
- Install the top cover
- Slide the server into the rack
- Reconnect the power cord (or cords) to the power supply (or supplies) and power on the server
OBTAIN CUSTOMER ACCEPTANCE
- WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO
AN OPERATIONAL STATE:
Boot up system and verify full functionality
Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID:
1539451.1
PARTS NOTE:
REFERENCE INFORMATION:
Sun Fire X4170, X4270, and X4275 Servers Service Manual
http://download.oracle.com/docs/cd/E19477-01/820-5830-13/index.html
How to shutdown the Exadata database nodes and storage cells in a rolling fashion so certain hardware tasks can be performed. (Doc ID 1539451.1)
Attachments
This solution has no attachment