Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1319296.1
Update Date:2018-05-22
Keywords:

Solution Type  Technical Instruction Sure

Solution  1319296.1 :   How to Replace a Sun Fire X4275 Fan Board  


Related Items
  • Sun Fire X4275 Server
  •  
  • Exadata Database Machine V2
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: x64-CAP VCAP
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: FRU CAP

Applies to:

Sun Fire X4275 Server - Version Not Applicable and later
Exadata Database Machine V2 - Version All Versions and later
Information in this document applies to any platform.

Goal

How to Replace a Sun Fire X4275 Fan Board.

Solution

DISPATCH INSTRUCTIONS

WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?:
Sun Fire X4275 Training

TIME ESTIMATE: 30 minutes

TASK COMPLEXITY: 1

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:

PROBLEM OVERVIEW: A Sun Fire X4275 Fan Board needs replacement

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :

A data backup is not a prerequisite but is a wise precaution.
The customer should conduct an orderly software system shutdown.

Then power down the system and disconnect the Power Cord.

Note: If this server is part of an Exadata, please follow shutdown instructions in DOC ID: 1188080.1

WHAT ACTION DOES THE ENGINEER NEED TO TAKE:

1. Power off the server and disconnect the power cord (or cords) from the power
supply (or supplies).
2. Remove the top cover.
3. Remove the fan modules.
4. Remove the Phillips screw that secures the fan power board to the chassis
5. Slide the fan power board to the right to disengage it from the standoffs.
6. Turn the fan power board over and disconnect the two cables attached to its
underside.
7. Remove the fan power board from the system and place it on an antistatic mat.

Installation is the reverse of the above procedure

Power On

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
Check for full system functionality

Note: If this server is part of an Exadata, please follow restart instructions in step 7 of DOC ID: 1188080.1


PARTS NOTE:
None

REFERENCE INFORMATION:
Sun Fire X4170, X4270, and X4275 Servers Service Manuals
http://download.oracle.com/docs/cd/E19477-01/
http://download.oracle.com/docs/cd/E19269-01/
http://download.oracle.com/docs/cd/E19871-01/

Steps to shut down or reboot an Exadata storage cell without affecting ASM (Doc ID 1188080.1)


Attachments