![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 1347280.1 : How to Replace a Sun Fire X4170, X4270 Power Distribution Board Ribbon Cable
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Exadata Database Machine V2 - Version All Versions to All Versions [Release All Releases]Sun Fire X4170 Server - Version Not Applicable to Not Applicable [Release N/A] Sun Fire X4270 Server - Version Not Applicable to Not Applicable [Release N/A] Information in this document applies to any platform. GoalHow to Replace a Sun Fire X4170, X4270 Power Distribution Board Ribbon Cable. SolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: TIME ESTIMATE: 60 minutes TASK COMPLEXITY: 1 FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: PROBLEM OVERVIEW: A Sun Fire X4170, X4270 Power Distribution Board Ribbon Cable needs replacement WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : A data backup is not a pre-requisite but is a wise precaution. Note: If this server is part of an Exadata, please follow shutdown instructions in Section 1 of DOC ID: 1539451.1
Note: If this server is part of an Exadata, please follow restart instructions in Section 1, step 10 of DOC ID: 1539451.1
How to shutdown the Exadata database nodes and storage cells in a rolling fashion so certain hardware tasks can be performed. (Doc ID 1539451.1) Attachments This solution has no attachment |
||||||||||||||||
|