2368990.1 |
E25K All Boards in Domain Fail in POST after Planned Reboot |
2018-03-07
|
2175979.1 |
Power supply faulty |
2018-02-19
|
2028757.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: System Controller Failed To Configure Floating Interface. |
2018-03-05
|
1988915.1 |
Sun Fire[TM] 12K/15K/20K/25K: USIV+ procs on SBX are running throttled, but are not in a split expander configuration that would require it. Bailing out to force a full post run so the procs can be reconfigured |
2018-05-17
|
1983281.1 |
Adding a systemboard fails with: Can't allocate VA for page_ts |
2015-02-27
|
1963443.1 |
Sun Fire[TM] 12K/15K/20K/25K: System controller : SMS fomd process does not start up. |
2017-12-06
|
1672184.1 |
SunFire[TM] 12K/15K/E20K/E25K:System Controller failover because SCPER1 is being deconfigured |
2017-02-24
|
1668946.1 |
Sun Fire[TM] 12K/15K/E20K/E25K Servers: Solaris instance on System Controllers (SCs) may hang during the execution of network command 'dladm show-link' |
2018-03-05
|
1620190.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: SMS fomd daemon generates warnings like "Propagation/retrieval of failed - check earlier messages for the following code: 50000" |
2017-09-29
|
1617929.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: domain panic, "pcisch-XX : Fatal PCI bus error(s)" |
2017-11-08
|
1589664.1 |
Sun Fire[TM] 12K/15K/20K/25K: POST: memory crunched (c), be aware of possible missing (m) processors |
2018-05-09
|
1586951.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: SCPER At SCPER1 Temp HIGH_WARN |
2017-10-11
|
1583980.1 |
SunFire[TM] 12K/15K/E20K/E25K:System Controller Is Down |
2017-10-11
|
1579362.1 |
Sun Fire[TM] 12K/15K/E20K/E25K servers: WARNING: Proc SBxx/Px Mask ID is up-version |
2017-10-11
|
1575303.1 |
Sun Fire[TM] 12K/15K/20K/25K: System Controller fails POST - CUR values "has been identified as being out of sharing range" in Platform Messages. |
2018-05-17
|
1575283.1 |
Sun Fire[TM] 12K/15K/20K/25K: Interpreting System Management Services(SMS) Failed FAN messages |
2013-08-12
|
1533153.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: System Board Voltage failure |
2017-10-11
|
1518071.1 |
Sun Fire[TM] 12K/15K/E20K/E25K:: the cfgadm command does not properly display the C5V0 device names for hsPCI+ IO board. (CR 15851760) |
2017-11-08
|
1507966.1 |
Sun SPARC Sun Fire 12K/15K/E20K/E25K (Starcat): NOTICE: Solaris failed to send a message (0x4/0x5309) to the System Controller. Error: 145 |
2017-11-08
|
1337295.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: No SOF interrupts have been received, this USB OHCI hostcontroller is unusable |
2018-04-02
|
1020543.1 |
Sun Fire[TM] 12K/15K/20K/25K: Esmd reports false voltage alarms on HPCI boards |
2014-12-03
|
1019902.1 |
Sun Fire[TM] E25K, E20K, E15K, E12K : "showboards" may report invalid power values when the locale is not set to "C" |
2017-12-06
|
1018867.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Mailbox Framework Failures, Even Without DR Operation |
2016-12-05
|
1018155.1 |
Sun Fire[TM] 12K/15K Servers : prtdiag reports "/IO31/P3" for SlotId and "-1" for PortId. |
2012-07-31
|
1018065.1 |
Virtual Console Daemon (cvcd) fails to start on a Solaris[TM] 10 High End Server domain. |
2014-07-07
|
1017937.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: UltraSPARC[R] IV Processors report over-temperature events. |
2012-07-31
|
1017727.1 |
System Management Services (SMS) 1.3 or older: flashupdate unable to flash boards with 5.19.X or newer |
2016-06-01
|
1017539.1 |
Sun Fire[TM] 12K/15K/E20K/E25K, Rio External Loopback Test failure |
2016-03-30
|
1017493.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Cheat Sheet: hsPCI, hsPCI+ and hsPCI-X Cartridge Locations |
2017-02-28
|
1012562.1 |
Sun Fire[TM] 12K/15K/E20K/E25K Servers: Incorrect boot path can cause forced-no-boot condition on a domain |
2018-03-06
|
1012322.1 |
Sun Fire[TM] 12K/15K/E20K/E25K System Management Services: The smsconnectsc command fails with "all ports busy" or just hangs. |
2016-09-12
|
1012320.1 |
Sun Fire[TM] 12K/15K/20K/25K: Domain reports "sun-dr/tcp: bind: Address already in use" |
2012-08-01
|
1012044.1 |
Sun Fire[TM] 12K/15K: Recognizing SMS split brain |
2014-10-10
|
1011843.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Duplicate Open Boot Prom (OBP) devaliases may prevent the system from booting |
2015-10-21
|
1010957.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: "uname -a" on a Sun Fire[TM] 12K/20K/25K reports Sun-Fire[TM]15000 |
2016-07-21
|
1010924.1 |
Sun Fire[TM] Server : Dynamic Reconfiguration (DR) fails due to Real Time (RT) process running. |
2017-02-02
|
1010750.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Domain fails HPOST test "PCI IOC External Functional Tests,SUBTEST=PCI IOC DMA External loopback Tests" |
2017-09-05
|
1010731.1 |
Sun Fire[TM] 12k/15k/E20k/E25k: IO board reporting "out of range" |
2016-03-01
|
1010722.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Error message "cfgadm: Hardware specific failure: unconfigure SB2: Failed to off-line: dr@0:SB2::cpu2" |
2015-09-07
|
1010705.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Reboot of one domain, 2 others dstop with ???Timeout on head of CI queue??? |
2016-07-21
|
1010600.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: "Domain failed by hpost: ecode=39" |
2016-07-01
|
1010336.1 |
Sun Fire[TM] 12K/15K/E20K/E25K : FOMD error 8563 - failed to configure logical interface |
2013-03-14
|
1010335.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Identifying and recovering from a domain hang |
2018-05-01
|
1009696.1 |
"kstat -p" and "prtdiag -v" may give seemingly different PCI bus speeds for Dual Fast Ethernet and Dual SCSI PCI Adapters |
2017-03-29
|
1009533.1 |
Sun Fire[TM] 12K/15K/20K/25K: DR not possible when CSB is blacklisted and domain configured with both Centreplane halves active |
2018-01-29
|
1009491.1 |
Sun Fire[TM] 12K/15K/E20K/E25K server : domain OS installation fails to move forward because of "an incorrect Solaris OS image" |
2013-03-14
|
1009267.1 |
Sun Fire[TM] 12K/15K/20K/25K cfgadm: Component system is busy, try again |
2015-01-22
|
1009124.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: showdevices takes a long time to return |
2012-07-31
|
1008914.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Console stuck in IOSRAM mode |
2017-04-04
|
1008905.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Safari Agent ID Cheat Sheet and Decoding CPU, Memory, and IOC Locations |
2017-08-01
|
1008904.1 |
Sun Fire[TM] 12K/15K/E20K/E25K Servers: Adding a user with the smsconfig command |
2013-03-18
|
1008805.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Remote Dynamic Reconfiguration (DR) generates "DCA/DCS Communication Error" and showdevices is ???Unable to get device information from domain???. |
2017-11-14
|
1008803.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: showdevices can hang if sd.conf is large or misleading |
2013-03-20
|
1008719.1 |
Resolving Hard Hang Problems on Sun Ultra Servers |
2016-04-15
|
1007966.1 |
Sun Fire[TM] 12K/15K E20K/E25K servers: Can't setkeyswitch domains. POST aborts with ecode=2 |
2015-12-16
|
1007939.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Solaris[TM] 10 DR detach of IO Board containing the dman interface fails with "Device busy: dr@0:IO<##>::pci2" |
2012-07-31
|
1007790.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: System Controller (SC) platform messages file reports "FRAD chkpt WRITE failed. session id: 128, return code: 8" errors. |
2014-09-26
|
1007782.1 |
Dynamic Reconfiguration or hot plug problems on a QGE HBA (4444A). |
2018-01-03
|
1007768.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Reply for ssc-seteeprom command failed |
2013-03-11
|
1007736.1 |
Diagnosing multiple DIMM CE errors occurring on multiple DIMMs |
2016-11-29
|
1007730.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: showdevices command fails on system controller |
2014-01-27
|
1007619.1 |
Sun Fire[TM] 12K/15K E20K/E25K system controller gives message WARNING: pcipsy0: spurious interrupt from ino 0x1c |
2017-03-22
|
1007591.1 |
Sun Fire[TM] 12K, 15K, E20K, E25K: OpenBoot[TM] Prom no Longer Accepts Shortened Disk Boot Device Paths in System Management Services (SMS) 1.4.1 |
2017-03-22
|
1006864.1 |
Sun Fire[TM] Mid Range and High end servers: Dynamic Reconfiguration for Uniboard removal may cause Lotus Domino server instance(s) to abnormally stop |
2017-02-02
|
1006728.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Connection to Nile proxy is down and could not be re-established, remote reporting aborted. |
2013-03-14
|
1006623.1 |
Domains on Sun Fire [TM] 12k/15k/E20k/E25k may dstop when SMS is simultaneously started on both SCs |
2016-10-04
|
1006575.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: After upgrading hsPCI to hsPCI+ domain fails to boot |
2018-01-10
|
1006491.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: System Controller /var/adm/messages shows many eri "link up" (and sometimes "link down") messages |
2017-04-04
|
1006327.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: The "setkeyswitch on" command fails with "FAIL Addr Bus C1: Cplane already in use with this bus deconfigured." |
2017-08-08
|
1006302.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Domain not Booting: "Domain failed by hpost: ecode=36" |
2017-11-14
|
1006249.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Solaris[TM] 8 domain hangs on resuming JNI I/O device driver |
2012-10-30
|
1006233.1 |
Sun Fire[TM] 12K/15K/20K/25K: Interpreting System Management Services(SMS) Failed Power Supply Messages |
2017-09-05
|
1006217.1 |
Sun Fire[TM] System Controller: Warning Message Appears After the CP1500 Board Replacement |
2017-03-22
|
1006156.1 |
"ERROR: Can't open boot device" booting CDROM or disk with Sun[TM] Dual FastEthernet / Dual SCSI PCI Card |
2017-02-02
|
1006088.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Dstop: AMX: Detected Header parity error from AXQ |
2014-10-02
|
1006050.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Interrupt not serviced messages on System Controller |
2017-03-22
|
1006045.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Incomplete removal of dynamic reconfiguration (DR) capability may lead to network hangs |
2015-10-08
|
1006038.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: WDC Event on CPU### at TL=0 |
2017-08-01
|
1005071.1 |
Sun Fire[TM] Servers (3800/4800/4810/6800/E4900/E6900): I2C communication problem |
2017-02-02
|
1005038.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Domain Reboots if the Open Boot PROM Boot Device Is Incorrect - dxs disconnected message |
2016-08-17
|
1004970.1 |
Sun Fire[TM] 12K/15K/E20K/E25K : System Management Services Software: upgrade to SMS 1.4.1 failed |
2013-03-14
|
1004721.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: forced-no-reboot Errors When Booting or Rebooting |
2018-04-02
|
1004712.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Domain reboot hangs at "resetting..." and does not run HPOST |
2018-04-02
|
1004618.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: frad daemon reports "Ignoring CRC error" or "TH Segment CRC is wrong on DIMM" |
2013-03-14
|
1004615.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: IDPROM layout for OpenBoot PROM failed |
2017-03-22
|
1004598.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Recovering from a System Controller disk failure |
2017-11-14
|
1003853.1 |
Sun Fire[TM] 12K/15K/20K/25K server found with DC Breaker in the 'off' position |
2016-05-02
|
1003727.1 |
Sun Fire[TM] 12K/15K:System Management Services: Upgrading SMS 1.3 to 1.4.1 fails with smsrestore error |
2013-03-06
|
1003585.1 |
Sun Fire [TM] 12K/15K: Cards Fail to be Configured in I/O Board Slot 1 if Slot 3 is Populated |
2018-05-01
|
1003552.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: SC POST results: 'Power On Selftest not run on last reset' |
2018-01-10
|
1003550.1 |
Sun Fire[TM] 12K - E25K / Sparc Enterprise Mx000: WARNING: fcode_timer: Timeout waiting for interpreter - Interpreter did not pick up request |
2017-07-10
|
1003334.1 |
Sun Fire[TM] 12K/15K/20K/25K: WARNING: mod_load: cannot load module 'scman' |
2017-09-05
|
1003321.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: POST: IBIST Failures |
2016-06-01
|
1003308.1 |
Sun Fire[TM]12K/15K/E20K/E25K: esmd warning; A power failure has been detected on a redundant power supply at ... |
2017-04-28
|
1002804.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Hpost Fails an IO Board which "Shares an Expander with an Unthrottled USIV+ Board which is Active in Another Domain." |
2018-01-23
|
1002762.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Seeprom never went ready errors after platform power on. |
2018-02-20
|
1002642.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: SMS Failover is disabled due to I2 network failure running on Solaris[TM] 10 Operating System with patch 122608-03 installed |
2017-03-22
|
1002437.1 |
Sun Fire[TM] 12K/15K/20K/25K: cfgadm -c disconnect fails with Library error: RCM request delete capacity failed for SB |
2015-12-02
|
1002417.1 |
Missing drv/clone forceload in /etc/system on a system with Emulex cards may cause panic during boot |
2017-02-02
|
1002244.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Troubleshooting a Dimm Failure during POST on an Othello+ System Controller |
2018-01-10
|
1002172.1 |
SPARC Sun Fire[TM] 12K/15K/E20K/E25K (Starcat): Domains won't setkeyswitch on - PICLD and POST |
2017-07-10
|
1002125.1 |
Sun Fire[TM] 15K/12K/E20K/E25K Servers: RCM Daemon hanging, causing DR operations to hang |
2017-05-01
|
1002119.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: "Error reading E$Dimm SBxx/P[0,1]/E[0,1] seeprom" reported for a 2-cpu board. |
2016-05-02
|
1002070.1 |
Sun Fire[TM] 12K/15K: frad SEEPROM error: "bad element: tag, expected value: 8, actual value: 0" |
2018-03-05
|
1002017.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: SunSAI/P serial port expansion cards are not compatible with Sun Fire servers |
2015-04-16
|
1002001.1 |
Sun Fire[TM] Servers: 12K/15K/E25K/E20K: Post passed but CPUs are missing under Solaris[TM] |
2012-07-31
|
1001923.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: smsconnectsc command gives "Unable to obtain a lock." errors |
2013-08-08
|
1001848.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Terminating a hpost reset/recovery loop test cycle on a domain |
2017-01-24
|
1001681.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Failover: Failing over to the spare SC because of the following faults on the main SC: Low System Memory |
2014-09-26
|
1001651.1 |
Sun Fire[TM] 12K/15K/E20K/E25K: Displaying domain ethernet addresses from the system controller |
2013-03-19
|