![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1006327.1 : Sun Fire[TM] 12K/15K/E20K/E25K: The "setkeyswitch on" command fails with "FAIL Addr Bus C1: Cplane already in use with this bus deconfigured."
PreviouslyPublishedAs 208878 Applies to:Sun Fire 12K Server - Version All Versions and laterSun Fire 15K Server - Version All Versions and later Sun Fire E20K Server - Version All Versions and later Sun Fire E25K Server - Version All Versions and later All Platforms SymptomsON SF12/SF15/SF20/SF25K platforms the "setkeyswitch on" command may fail with "FAIL Addr Bus C1: Cplane already in use with this bus deconfigured" error: gu15ka-sc1:sms-svc:8> setkeyswitch -d i on Powering on: CSB at CS1 Already powered on: CSB at CS1 Powering on: CSB at CS0 Already powered on: CSB at CS0 Waiting on exclusive access to EXB(s): 00100. Powering on: EXB at EX8 Powering on: HPCI at IO8 Powering on: CPU at SB8 Powering on: EXB at EX13 Powering on: HPCI at IO13 Powering on: CPU at SB13 Significant contents of .postrc (platform) /etc/opt/SUNWSMS/SMS1.4.1/config/platform/.postrc: # ident "@(#)postrc 1.1 01/04/02 SMI" Reading domain blacklist file /etc/opt/SUNWSMS/config/I/blacklist ... # ident "@(#)blacklist 1.1 01/04/02 SMI" Reading platform blacklist file /etc/opt/SUNWSMS/config/platform/blacklist ... # ident "@(#)blacklist 1.1 01/04/02 SMI" SEEPROM probe took 0 seconds. Reading Component Health Status (CHS) information ... stage lport_reset: Assert reset to IOC ports in -Q mode... stage_lport_reset(): Not -Q mode; Skipping Stage lport_reset stage bus_probe: Check in-use bus configurations... FAIL Addr Bus C1: Cplane already in use with this bus deconfigured. There is no FRU service action indicated for this failure. FAIL Data Bus C1: Cplane already in use with this bus deconfigured. There is no FRU service action indicated for this failure. FAIL Resp Bus C1: Cplane already in use with this bus deconfigured. There is no FRU service action indicated for this failure. Changes
CauseWhen a CSB is failed or deconfigured, the result is all three buses on the centerplane will be deconfigured for that CSB. These are the Address bus, Data bus, and Response bus. If CSB0 is faulty or deconfigured then the C0 buses will be deconfigured, and if CSB1 is faulty or deconfigured then the C1 buses will be deconfigured.
SolutionOnce the CSB is replaced or powered on, then the corresponding C-buses can be configured with the "setbus" command. xcat-sc0% showbus -v ----------------- SOCX: 0x18002 ----------------- Address: BOTH Data: BOTH Response: BOTH ----------------- Domain: A xcat-domain-a xcat-domain-a ON/Running Solaris Location: EX1 SB1: On/active IO1: On/active Location: EX16 SB16: On/active Domain: B xcat-domain-b xcat-domain-b ON/Running Solaris Location: EX15 SB15: On/active IO15: On/active Location: EX16 IO16: On/active ----------------- SOCX: 0x00004 ----------------- Address: BOTH Data: BOTH Response: BOTH ----------------- Domain: C xcat-domain-c xcat-domain-c ON/Running Solaris Location: EX2 SB2: On/active IO2: On/active ----------------- SOCX: 0x00060 ----------------- Address: BOTH Data: BOTH Response: BOTH ----------------- Domain: P pts-1 xcat-domain-p ON/Running Solaris Location: EX5 IO5: On/active Location: EX6 SB6: On/active IO6: On/active Domain: Q pts-2 - OFF/Powered Off Location: EX5 SB5: Off/assigned ----------------- SOCX: 0x20000 ----------------- Address: BOTH Data: BOTH Response: BOTH ----------------- Domain: D xcat-domain-d xcat-domain-d ON/Running Solaris Location: EX17 SB17: On/active IO17: On/active ----------------- UNCONFIGURED ----------------- Domain: P pts-1 xcat-domain-p ON/Running Solaris Location: EX7 SB7: Off/assigned Domain: Q pts-2 - OFF/Powered Off Location: EX7 IO7: Off/assigned Location: EX8 SB8: Off/assigned ----------------- UNASSIGNED ----------------- Location: EX8 SB8: Off/unassigned
xcat-sc0% setbus -c cs0 Waiting on hpost(1M) schedule request: 3FFFF. Configuring socx 0x38066 xcat-sc0% showbus -v ----------------- SOCX: 0x18002 ----------------- Address: CSB0 Data: CSB0 Response: CSB0 ----------------- Domain: A xcat-domain-a xcat-domain-a ON/Running Solaris Location: EX1 SB1: On/active IO1: On/active Location: EX16 SB16: On/active Domain: B xcat-domain-b xcat-domain-b ON/Running Solaris Location: EX15 SB15: On/active IO15: On/active Location: EX16 IO16: On/active ----------------- SOCX: 0x00004 ----------------- Address: CSB0 Data: CSB0 Response: CSB0 ----------------- Domain: C xcat-domain-c xcat-domain-c ON/Running Solaris Location: EX2 SB2: On/active IO2: On/active ----------------- SOCX: 0x00060 ----------------- Address: CSB0 Data: CSB0 Response: CSB0 ----------------- Domain: P pts-1 xcat-domain-p ON/Running Solaris Location: EX5 IO5: On/active Location: EX6 SB6: On/active IO6: On/active Domain: Q pts-2 - OFF/Powered Off Location: EX5 SB5: Off/assigned ----------------- SOCX: 0x20000 ----------------- Address: CSB0 Data: CSB0 Response: CSB0 ----------------- Domain: D xcat-domain-d xcat-domain-d ON/Running Solaris Location: EX17 SB17: On/active IO17: On/active ----------------- UNCONFIGURED ----------------- Domain: P pts-1 xcat-domain-p ON/Running Solaris Location: EX7 SB7: Off/assigned Domain: Q pts-2 - OFF/Powered Off Location: EX7 IO7: Off/assigned Location: EX8 SB8: Off/assigned ----------------- UNASSIGNED ----------------- Location: EX8 SB8: Off/unassigned
Attachments This solution has no attachment |
||||||||||||
|