![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1002642.1 : Sun Fire[TM] 12K/15K/E20K/E25K: SMS Failover is disabled due to I2 network failure running on Solaris[TM] 10 Operating System with patch 122608-03 installed
PreviouslyPublishedAs 203643 Applies to:Sun Fire E20K Server - Version Not Applicable and laterSun Fire E25K Server - Version Not Applicable and later Sun Fire 12K Server - Version Not Applicable and later Sun Fire 15K Server - Version Not Applicable and later All Platforms SymptomsSMS (System Management Services) Failover is disabled due to I2 network failure. sms% showfailover -v
SC Failover Status: FAILED Status of Shared Memory: HASRAM (CSB at CS0): ................................Powered Off HASRAM (CSB at CS1): ................................Powered Off Status of sc0: Role: .......................................MAIN SMS Daemons: .......................................Good System Clock: .......................................Good Private I2 Network: .....................................FAILED Private HASRAM Network: .....................................FAILED Public Network: .................................NOT TESTED System Memory: ........................................4.7% Disk Status: ........................................1.4% Console Bus Status: .................................NOT TESTED ** Unable to retrieve status from remote SC. eri: SUNW,eri1 : 100 Mbps full duplex link up
Apr 21 18:34:47 sc0 eri: SUNW,eri2 : No response from Ethernet network : Link down -- cable problem? Apr 21 18:34:48 sc0 eri: SUNW,eri2 : 100 Mbps full duplex link up Apr 21 18:34:57 sc0 eri: SUNW,eri1 : 100 Mbps full duplex link up Apr 21 18:35:07 sc0 eri: SUNW,eri2 : 100 Mbps full duplex link up Apr 21 18:35:15 sc0 eri: SUNW,eri1 : No response from Ethernet network : Link down -- cable problem? ChangesPatch ID 122608-03 was installed on Solaris[TM] 10 Operating System. CauseThis SUNWjass patch enables ipfiltering. With ipfiltering enabled in a generic way, all communications between SCs on the I2 network is blocked. Hence, I2 network fails, and failover is disabled. SolutionA fix for Bug ID 6537623 has been implemented in 122608-05. Relief/Workaround1) Change /opt/SUNWjass/Files/etc/ipf/ipf.conf-15k_sc *AND*
After changing you MUST reboot OR restart the ipfilter SMF service (svcadm restart ipfilter).
Then reboot. # svcadm disable ipfilter SMS, S10, Solaris 10, failover, ipfilter, SST, I2 network, FAILED Attachments This solution has no attachment |
||||||||||||
|