Solution Type  Problem Resolution Sure

Solution  1001681.1 :   Sun Fire[TM] 12K/15K/E20K/E25K: Failover: Failing over to the spare SC because of the following faults on the main SC: Low System Memory  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
  • Sun Fire E20K Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: SF-Exxk
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>High-End Servers
  •  

PreviouslyPublishedAs
202286


Applies to:

Sun Fire 12K Server - Version Not Applicable and later
Sun Fire E25K Server - Version Not Applicable and later
Sun Fire 15K Server - Version Not Applicable and later
Sun Fire E20K Server - Version Not Applicable and later
All Platforms

Symptoms


Main SC fails over to spare SC due to low system memory.


Messages from Main SC:

Jun 28 11:25:50 2002 hostname fomd[347]: [8567 2220835155213 NOTICE Failover Mgr.cc 1782] Failing over to the spare SC because of the following faults on the main SC: Low System Memory


Messages from Spare SC:

Jun 28 11:26:37 2002 hostname fomd[378]: [8573 632701993069 NOTICE FailoverMgr.cc 2010] Taking over the main role because the remote SC (current Main) has a fault - Low System Memory

 

Cause

Invalid swap space allocation has caused a low memory condition.

Solution

Display your swap devices:

hostname:sms-svc:5> swap -l
swapfile                 dev    swaplo blocks   free
/dev/dsk/c0t3d0s1 32,25 16        263856 263856

Take the number under the blocks column * 512.
For example: 263856*512=135,094,272

In this case, there is approximately 135 megabytes of swap.

There must be at least 2 gigabytes of swap.

Add swap space to your existing swap space to total at least 2 gigabytes.

NOTE: Verify BOTH the main & spare SC have at least 2 gigabytes of swap space.

Space allocation requirements can be found on Page 6 of the System Management Services (SMS) 1.6 Installation Guide.

For memory issue while running third party applications on the system controller see the Open SC Document.