Solution Type Problem Resolution Sure Solution 1001681.1 : Sun Fire[TM] 12K/15K/E20K/E25K: Failover: Failing over to the spare SC because of the following faults on the main SC: Low System Memory
PreviouslyPublishedAs 202286 Applies to:Sun Fire 12K Server - Version Not Applicable and laterSun Fire E25K Server - Version Not Applicable and later Sun Fire 15K Server - Version Not Applicable and later Sun Fire E20K Server - Version Not Applicable and later All Platforms Symptoms
Jun 28 11:25:50 2002 hostname fomd[347]: [8567 2220835155213 NOTICE Failover Mgr.cc 1782] Failing over to the spare SC because of the following faults on the main SC: Low System Memory
Jun 28 11:26:37 2002 hostname fomd[378]: [8573 632701993069 NOTICE FailoverMgr.cc 2010] Taking over the main role because the remote SC (current Main) has a fault - Low System Memory
CauseInvalid swap space allocation has caused a low memory condition. SolutionDisplay your swap devices: hostname:sms-svc:5> swap -l
swapfile dev swaplo blocks free /dev/dsk/c0t3d0s1 32,25 16 263856 263856 Take the number under the blocks column * 512. There must be at least 2 gigabytes of swap. Add swap space to your existing swap space to total at least 2 gigabytes. NOTE: Verify BOTH the main & spare SC have at least 2 gigabytes of swap space.
Space allocation requirements can be found on Page 6 of the System Management Services (SMS) 1.6 Installation Guide. For memory issue while running third party applications on the system controller see the Open SC Document. Attachments This solution has no attachment |
||||||||||||
|