Problem Document
|
Synopsis
|
Last Modified Date
|
2329333.1 |
Sun SPARC Enterprise Mx000 Server: How to Troubleshoot XSCFU WDT event SCF-8005-NE due to Error "Recovery of wbuf failed due to a second write error" |
2017-11-20
|
2192795.1 |
SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: upon XSCF reboot, sckmd pppd and scfd daemons may generate messages on Solaris domain that can be interpreted as faults |
2017-09-29
|
2149494.1 |
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: "Fast Data Access MMU Miss" error along with BERR/BTO event during boot may be due to root file-system inconsistencies |
2017-09-29
|
2121677.1 |
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 How to Handle XSCFU WARNING: audit trail is 99% full |
2017-09-06
|
2112004.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: XSCF SNMP Can take up to 1 hour to report a PSU AC input failure |
2017-10-03
|
2070764.1 |
300GB, 600GB, 900GB, and 1.2 TB Disk Firmware Upgrade to Address Unrecoverable Read Errors in SPARC Platforms. |
2017-07-17
|
2027630.1 |
Hard Disk Not Seen In format After Physical Replacement |
2018-03-05
|
1998049.1 |
Solaris 10 Hung While Booting With Errors mpt_cmd_timeout: Restarting HBA - Failed Internal Disk Controlled by Mpt Driver |
2017-10-06
|
1994858.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: XSCF's hostname set to "localhost" may cause XSCF unplanned reboots and domain(s) outage |
2017-09-29
|
1993928.1 |
M4000 Domain Panics Reporting Fatal Error Has Occured in: PCIe fabric.(0x1)(0x45) and subsequent reboots Fails with Same Panic |
2018-05-24
|
1993872.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: XSCF Reports Bad Data CRC Error at Console After Power Cycle and Loops uboot |
2017-04-27
|
1988103.1 |
Sun SPARC Enterprise M8000, M9000 - Solaris 11 Dynamic Reconfiguration (DR) failes due to "Unable To Probe PCI Leaf" |
2018-03-05
|
1982428.1 |
Sun SPARC Enterprise[TM] M3000/M4000/M5000/M8000/M9000: XSCF marked degraded with FMA code SCF-8006-WP, error reading inode #3082 |
2018-05-08
|
1981543.1 |
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Server: A Slower Hard Disk was Sent as a Replacement |
2017-10-05
|
1955763.1 |
Sun SPARC[R] Enterprise M3000/M4000/M5000/M8000/M9000 (OPL): XCP flashupdate command fails with error "This XSCF flash memory bank was switched by the XSCF board due to a previously encountered error condition" |
2017-11-16
|
1945858.1 |
Failed to save core dump due to "panic: entering debugger (continue to save dump)" |
2018-03-01
|
1942533.1 |
M-Series Servers: XSCF watchdog timeout without auto negotiation on Ethernet port |
2018-05-17
|
1941503.1 |
Sparc Enterprise M3000/M4000/M5000/M8000/M9000 Servers: XSCF may be affected by security scanner tools running on the network generating SCF-800x-xx events |
2017-04-05
|
1665705.1 |
Sun SPARC(R)Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Server: Ethernet LAN cable inserted into XSCF Serial Port may cause XSCF panic |
2017-11-16
|
1665479.1 |
Sparc Enterprise M8000/M9000 Servers: XSCF commands don't work after XCP upgrade |
2017-11-08
|
1625567.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: HW RAID Considerations and Issues |
2017-05-16
|
1620578.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: XSCF displays memory error detected during boot |
2017-10-19
|
1617956.1 |
I/O SERD threshold values are set too low and may result in PCIEX-8000-J5, PCIEX-8000-YJ and PCIEX-8000-KP faults. |
2017-08-22
|
1599463.1 |
Amber light on the Mx000 Server lit without an error |
2018-03-05
|
1591230.1 |
Diagnosing iostat Hard Errors on SPARC Servers DVD ROM |
2018-02-15
|
1562146.1 |
'replacefru' for XSCFU_B ends with [Warning:311] due to wrong procedure |
2018-05-09
|
1547333.1 |
XSCF commands fail with 'Permission denied' error message |
2018-03-01
|
1546140.1 |
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 - Cannot Change Password for a user on XSCF and 'password: Operation failed' is displayed |
2018-03-01
|
1531624.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 Server domain aborts auto-boot even though OBP variable auto-boot? is set to true. |
2017-04-27
|
1524340.1 |
73GB, 146GB, and 300GB Firmware Upgrade to Prevent Disk Drive Failures in SPARC platforms. |
2018-05-09
|
1516187.1 |
"Eject" button does not work on internal DAT72 drive. |
2018-02-16
|
1509059.1 |
Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 Identifying HDDx of internal disks under mpxio control and removing internal disks from mpxio control |
2018-04-05
|
1507710.1 |
Failed SSH login attempts on SPARC Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers domain(s) coming from XSCF(s) |
2017-09-29
|
1484297.1 |
bge related "spurious interrupt from ino" messages on M5000 |
2018-05-09
|
1451275.1 |
Sun SPARC[R] Enterprise M3000/M4000/M5000/M8000/M9000 Servers (OPL): Why FMA Events remain in the FMA history of M-Series XSCFUs |
2017-11-16
|
1446655.1 |
Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 / DSCP : ipsec_check_inbound_policy: Policy Failure for the incoming packet (not secure); |
2016-07-01
|
1432156.1 |
Sun SPARC(R) Enterprise M8000/M9000: 8mm DAT Drive & DVD is unavailable from domain(s) |
2018-04-09
|
1393137.1 |
Sun SPARC(R) Enterprise m3000/m4000/m5000/m8000/m9000 (OPL) domain not responding to sendbreak due to Secure Mode on, Have it Off to be Able to Force a Kernel Crash Dump |
2017-05-23
|
1381431.1 |
Oracle VTS may generate "Return value is -1" errors when run on M3000/M4000/M5000/M8000/M9000 platform where SPARC64 VII+ cpus are installed |
2017-09-29
|
1368440.1 |
How To resolve 3 X Power supply units marked as failed on M8000/M9000 running on single phase |
2016-07-01
|
1361607.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Panel EEPROM and XSCF FMEM mismatched |
2018-02-28
|
1330510.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 Server: XSCF Email Reporting does not cover power and temperature events |
2018-03-01
|
1328713.1 |
Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 : CMU Upgrade Fails with SCF-8002-LX and SCF-8002-K2 MSG-IDs |
2017-01-30
|
1300019.1 |
Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Server: delayed delivery of FMA mail messages from the XSCF |
2015-12-22
|
1020429.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Domain hang-up detected (POST); FMA event SCF-8005-RA |
2018-03-01
|
1020256.1 |
Sun SPARC(R)Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Server: : DIMMs are suddenly marked faulty after upgrading kernel patches |
2017-05-01
|
1019515.1 |
SunMC Agent will not start on a M8000/M9000 XSCF |
2012-07-31
|
1019405.1 |
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: SAS WWID becoming unprogrammed |
2017-10-30
|
1019156.1 |
Sun External I/O Expansion Unit PSU Status either Faulted or Degraded after removal and insertion of the AC power cords |
2018-04-09
|
1003550.1 |
Sun Fire[TM] 12K - E25K / Sparc Enterprise Mx000: WARNING: fcode_timer: Timeout waiting for interpreter - Interpreter did not pick up request |
2017-07-10
|