![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1665705.1 : Sun SPARC(R)Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Server: Ethernet LAN cable inserted into XSCF Serial Port may cause XSCF panic
Connecting an Ethernet LAN cable to an M3000/M4000/M5000/M8000/M9000 XSCF Serial Port can cause the XSCF to panic In this Document
Created from <SR 3-8865278952> Applies to:Sun SPARC Enterprise M9000-64 Server - Version All Versions and laterSun SPARC Enterprise M9000-32 Server - Version All Versions and later Sun SPARC Enterprise M3000 Server - Version All Versions and later Sun SPARC Enterprise M4000 Server - Version All Versions and later Sun SPARC Enterprise M5000 Server - Version All Versions and later Information in this document applies to any platform. SymptomsDuring diagnosis of an XSCF panic, which will be reported in the error logs as shown: Date: Mar 21 06:21:11 BST 2014 Code: 40000000-c201faff-011d001100000000
Status: Information Occurred: Mar 21 06:21:11.921 BST 2014 FRU: /XSCFU,/FIRMWARE Msg: XSCF panic detected Diagnostic Code: 00000000 00000000 00000000 50524f43 206e6f20 72657370 6f6e7365 00000000 00000000 00000000 00000000 UUID: c2f88101-5c87-4c9e-9214-c2235b696dee MSG-ID: SCF-8006-YS As of XCP1091, the following messages might be noted in the XSCF Linux messages files, located in spos_logs/@var@log@messages in the XSCF snapshot: Apr 16 12:31:47 (none) kernel: Serial: 8250/16550 driver [W] An interrupt occurs frequently on a serial port0.
Apr 16 12:31:47 (none) last message repeated 11 times
Changes
CauseThis is an indication that an Ethernet LAN cable has been inadvertently connected to the serial port of the XSCF, as opposed to the XSCF-LAN ports. The XSCF serial port is an RS-232C connection using a RJ45 connector , as detailed in the SPARC Enterprise Mx000 Servers XSCF User's Guide. This is one of many possible causes of FMA code SCF-8006-YS. Important Note : since this change was introduced in 1091, the following message can be observed on the M8000/M9000 systems. SolutionAlways ensure only serial cables are inserted into the XSCF Serial Port. ReferencesSPARC Enterprise Mx000 Servers XSCF User's Guide http://docs.oracle.com/cd/E19415-01/E25381/E25381.pdfAttachments This solution has no attachment |
||||||||||||||||||||
|