Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1361607.1
Update Date:2018-02-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  1361607.1 :   Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Panel EEPROM and XSCF FMEM mismatched  


Related Items
  • Sun SPARC Enterprise M8000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
  • Sun SPARC Enterprise M3000 Server
  •  
  • Sun SPARC Enterprise M9000-32 Server
  •  
  • Sun SPARC Enterprise M9000-64 Server
  •  
  • Sun SPARC Enterprise M5000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  


A firmware mismatch error is generated when replacing an XSCFU board that has a different firmware version than the original.

Created from <SR 3-4532707961>

Applies to:

Sun SPARC Enterprise M8000 Server - Version All Versions and later
Sun SPARC Enterprise M9000-64 Server - Version All Versions and later
Sun SPARC Enterprise M9000-32 Server - Version All Versions and later
Sun SPARC Enterprise M5000 Server - Version All Versions and later
Sun SPARC Enterprise M4000 Server - Version All Versions and later
Information in this document applies to any platform.

Symptoms

The following error message is generated during XSCF login:

XCP version of Panel EEPROM and XSCF FMEM mismatched,

        Panel EEPROM=1061, XSCF FMEM=1092

 

Note: revisions in the previous output are an example and will vary.


Changes




Cause

This problem may be experienced in different scenarios:

  • when a defective XSCFU is replaced with one that has a different version of FW from the version installed on the Panel (OPNL)
  • when a defective OPNL is replaced with one that has a different version of FW from the version installed on the XSCFU
  • following a FW upgrade that had some problem

 

Solution

Re-flash the XCP FW to synchronize the versions between the panel EEPROM and the XSCFU FMEM.
     Instructions for upgrading (i.e., flashing) the XCP FW can be found in the XSCF Users Guide. 
     Links to current FW can be found in Document 1002631.1

     Be aware that updating from versions below 1061 to a version higher than 1061
     requires an interim update to 1061 first.

 

The following additional solution applies only for M8000/M9000 systems (i.e., those servers with dual redundant XSCFU)
If an XSCFU is cold-replaced (i.e., with server AC power removed) the new board's firmware will not be updated as happens automatically during 'replacefru'.
Use the below commands to syncronize the firmware and then confirm the XSCFU FMEM matches.

1.  Use the flashupdate command to sync the panel EEPROM and the XSCFU FMEM versions.

      XSCF> flashupdate -c sync

2. Confirm that the version is corrected.
   
      XSCF>  version -c xscf