Solution Type Problem Resolution Sure Solution 1019156.1 : Sun External I/O Expansion Unit PSU Status either Faulted or Degraded after removal and insertion of the AC power cords
PreviouslyPublishedAs 236221 An action plan to correct this situation is provided. Oracle Confidential PARTNER - Available to partners (SUN). Reason: Migrated distribution from Sun Applies to:Sun SPARC Enterprise M4000 Server - Version All Versions and laterSun SPARC Enterprise M5000 Server - Version All Versions and later Sun SPARC Enterprise M9000-32 Server - Version All Versions and later Sun SPARC Enterprise M9000-64 Server - Version All Versions and later Sun SPARC Enterprise M8000 Server - Version All Versions and later All Platforms SymptomsThe Sun External I/O Expansion Unit PSU Status may become either Faulted or Degraded after removal and insertion of the AC power cords. ChangesThe Sun External I/O Expansion Unit PSU Status will become Faulted or Degraded after removal and insertion of the AC power cords with the power switch in the ON position. The XSCF 'clearfault' command will not be able to clear the status prior to required steps to be taken on the Sun External I/O Expansion Unit. CauseThe root of this problem appears to be an issue with the micro controller within the PSU. When this problem occurs, their appears to several asserted GPIO pins on the controller, indicating error conditions that don't actually exist. The Fan Controller then reads these registers and notifies iomgr about the error conditions. iomgr then logs these errors and writes to the PSU SEEPROM, faulting the PSU. SolutionThe Sun External I/O Expansion Unit Status LED will be lit, in addition to the XSCF showstatus reporting the PSU as Faulted or Degraded. A series of steps must be executed on the Sun External I/O Expansion Unit prior to executing the 'clearfault' command on the XSCF. Otherwise the Fault Status will return and the Status LED will remain lit. Steps to be Taken on the Sun External I/O Expansion Unit to clear fault state on the unit's micro-controller
Steps to be Taken on the XSCF utilizing the 'clearfault' command
Note: In XCP1115 and later clearfault does not require service mode. ExampleXSCF> enableservice Example:XSCF> clearfault /IOX@X0U4/PS0 Internal Comments
Attachments This solution has no attachment |
||||||||||||
|