How To
|
Canned Action Plan (CAP) Documents
|
Last Modified Date
|
1361150.1 |
How to Perform On Site Diagnosis for a Down System for Sun Fire T1000/T2000, SPARC Enterprise T1000/T2000, Sun Blade T6300 and Netra T2000:ATR:1361150.1:2 |
2017-11-30
|
1308290.1 |
How to Replace a Sun Fire or Netra T2000 Service Processor (ALOM) [VCAP] |
2017-08-14
|
1308289.1 |
How to Remove and Replace a Sun Fire T2000 System Board:ATR:1184:2 |
2016-12-19
|
1308281.1 |
How to Replace a Sun Fire and Netra T2000 DVD:ATR:1602:1 |
2017-12-01
|
1308279.1 |
How to Remove and Replace a Sun Fire T2000 LED/Switch Board:ATR:1181:1 |
2017-12-01
|
1308278.1 |
How to Replace a Sun Fire T2000 Service Processor Battery [VCAP] |
2017-08-15
|
1308276.1 |
How to Replace a Sun Fire T2000 Memory DIMM:ATR:1179:0 [Video] |
2017-08-02
|
1308261.1 |
How to Replace a Sun Enterprise/Fire or Netra T2000 Power Supply:ATR:1183:0 [VIDEO] |
2017-08-04
|
1308260.1 |
How to Remove and Replace a Sun Fire T2000 Power Distribution Board:ATR:1661:2 |
2016-10-03
|
1308252.1 |
How to Remove and Replace a Sun Fire/Sun SPARC Enterprise T2000 PCI-X SAS Controller:ATR:1604:0 |
2016-05-03
|
1307838.1 |
How to Remove and Replace a Sun Fire T2000 Front I O Board:ATR:1177:1 |
2016-05-25
|
1307834.1 |
How to Remove and Replace a Sun Fire T2000 Rear Fan Tray:ATR:1174:0 [Video] |
2017-08-04
|
1307826.1 |
How to Remove and Replace a Sun Fire T2000 CPU Fan:ATR:1172:0 [Video] |
2017-08-01
|
1307821.1 |
How to Remove and Replace a Sun Fire/Enterprise T2000 Server Fan Board:ATR:1170:1 |
2016-05-17
|
1307820.1 |
How to Remove and Replace a Sun Fire T2000 Disk Backplane:ATR:1167:1 |
2016-08-18
|
1307817.1 |
How to Remove and Replace a Sun Fire T2000 PCI Card:ATR:1164:0 |
2016-05-03
|
1307809.1 |
How to Remove and Replace a Sun Fire/Sun Enterprise T2000 Graphics Card:ATR:1176:0 |
2016-05-03
|
1307783.1 |
How to Replace a Sun Fire or Netra T2000 Hard Disk Drive:ATR:1169:0 |
2017-10-10
|
1307753.1 |
How to Remove and Replace a Sun Fire T2000 HBA:ATR:1166:0 [Video] |
2017-08-02
|
1307437.1 |
How to Remove and Replace Sun Fire/Enterprise T2000 Cable Kit:ATR:1601:1 |
2016-05-17
|
1307436.1 |
How to Remove and Replace a Sun Fire/Sun Enterprise T2000 Power Cord Kit:ATR:1162:0 |
2016-05-03
|
1019720.1 |
How to Replace the Motherboard or Service Processor in a Logical Domain (LDom) Environment |
2018-02-08
|
How To
|
Non CAP Knowledge Documents
|
Last Modified Date
|
2227574.1 |
How to diagnose missing resources in SPARC CMT systems |
2018-05-01
|
1604401.1 |
How to troubleshooting an issue with locator LED/button where it is not working gracefully when pressed. |
2017-10-05
|
1571240.1 |
Tx000/T5x20/T5x40: How To Clear recurring faults on Solaris FMA and System Controller after hardware replacement |
2018-05-17
|
1452873.1 |
How to Recognize and Diagnose Service Processor Battery Failure on Sun Fire/Netra T1000/T2000 & Sun Blade T6300/T6320/T6340 |
2017-05-22
|
1020016.1 |
Verify link configuration and vnet settings in LDOM |
2017-10-02
|
1020006.1 |
Steps to ensure there are no disk failures in LDOM environment |
2017-11-30
|
1019594.1 |
ALOM network port unresponsive after network switch power cycle |
2017-11-30
|
1018181.1 |
How to delete a RAID volume on Sun Fire V215/V245/T1000/T2000 at the OBP level |
2017-11-30
|
1012949.1 |
How to Determine the System Firmware Version on T1000/T2000 |
2018-01-05
|
1012645.1 |
How to Collect ALOM Data from the OS on T1000/T2000 Servers |
2017-10-05
|
1012360.1 |
How to determine which systems have ILOM/ALOM4v/ALOM/LOM/ELOM/SP/XSCF or RSC ? |
2018-03-01
|
1011227.1 |
How to verify that the Boot devices can be seen for the Sun Fire[TM] T1000/T2000 |
2018-01-05
|
1011226.1 |
Selecting the firmware upgrade method on T1000/T2000 |
2017-10-11
|
1010905.1 |
Oracle Enhanced Memory DIMM Replacement Policy for SPARC |
2018-04-26
|
1008481.1 |
Ensure that Jumpstart / Boot Server can be contacted from the current network port. |
2014-09-22
|
1008474.1 |
Ethernet cable and switch connection checks when cable or connection are suspect |
2018-03-23
|
1007005.1 |
How to activate a RAID volume on T1000/T2000, V215/V245/V445, T5120/T5220, T5140/T5240/T5440, T6300/T6320/T6340 Servers |
2018-01-31
|
1005907.1 |
SPARC Platforms: Matrix of Recognized Device Paths |
2018-02-28
|
1004229.1 |
How To Clear FMA faults from Solaris[TM] and SC (System Controller) on T1000/T2000 T5120/T5220/T5140/T5240/T5440,T6320,T6340, T3-1/T3-2/T3-4, T4-1/T4-2/T4-4 |
2018-03-14
|
1003456.1 |
STMS (MPxIO) degraded path messages seen at Solaris[TM] 8, 9, 10, or 11 boot time. |
2017-11-30
|