Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1308261.1
Update Date:2017-08-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  1308261.1 :   How to Replace a Sun Enterprise/Fire or Netra T2000 Power Supply:ATR:1183:0 [VIDEO]  


Related Items
  • Sun Fire T2000 Server
  •  
  • Sun Netra T2000 Server
  •  
  • Sun SPARC Enterprise T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
  •  
  • Microlearning>Video>ML-VID-VCAP
  •  




Applies to:

Sun Fire T2000 Server - Version Not Applicable and later
Sun SPARC Enterprise T2000 Server - Version Not Applicable and later
Sun Netra T2000 Server - Version Not Applicable and later
Information in this document applies to any platform.

Goal

How to Replace a T2000 Power Supply

*************************************************************************************
To report errors or request improvements on this procedure, please Add a comment on Doc ID: 1308261.1
*************************************************************************************

Solution



DISPATCH INSTRUCTIONS

WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure

TIME ESTIMATE: 90 minutes

TASK COMPLEXITY: 0

REMOVAL/REPLACEMENT INSTRUCTIONS

PROBLEM OVERVIEW:  Faulty T2000 Power supply

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
If no redundant power is available shutdown system and power off unit. Otherwise the server's redundant hot-swappable power supplies enable you to remove and replace a power supply without shutting the server down (while server is running), provided that the other power supply is online and working.

NOTE: If a power supply fails and you do not have a replacement available, leave the failed power supply installed to ensure proper air flow in the server.

WHAT ACTIONS ARE REQUIRED:
Replacing only one power supply in a dual power configuration.

1. Identify which power supply (0 or 1) requires replacement.  A lighted amber LED on a power supply indicates that a failure was detected. You can also use the showfaults command at the sc> prompt.

2. At the sc> prompt, issue the removefru command.  The removefru command indicates if it is OK to perform a hot-swap of a power supply. This command does not perform any action, but provides a warning if the power supply should not be removed because the other power supply is not providing power to the server. Example:

sc> removefru PSn (Note: n is 0 or 1)
Are you sure you want to remove PS0 [y/n]? y
<PSn> is safe to remove.

3. Gain access to the rear of the server where the faulty power supply is located.

4. At the rear of the server, release the cable management arm (CMA) tab and swing the CMA out of the way so you can access the power supply.

5. Disconnect the power cord from the faulty power supply.

6. Grasp the power supply handle and push the power supply latch to the right.

7. Pull the power supply out of the chassis.

8. Align the replacement power supply with the empty power supply bay.

9. Slide the power supply into bay until it is fully seated.

10. Reconnect the power cord to the power supply.

11. Close the CMA, inserting the end of the CMA into the rear left rail bracket.

12. Verify that the amber LED on the replaced power supply, the Service Required LED, and Rear-FRU Fault LEDs are not lit.

13. At the sc> prompt, issue the showenvironment command to verify the status of the power supplies.

OBTAIN CUSTOMER ACCEPTANCE

WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: N/A

PARTS NOTE:

Sun Fire T2000 https://support.oracle.com/handbook_private/Systems/SunFireT2000/components.html#Power

Sun Fire T2000 (post July 2006) https://support.oracle.com/handbook_private/Systems/SunFireT2000_R/components.html#Power

Sun Enterprise T2000 https://support.oracle.com/handbook_private/Systems/SE_T2000/components.html#Power

Netra T2000 https://support.oracle.com/handbook_private/Systems/Netra_T2000/components.html#Power


REFERENCE INFORMATION:
Sun Fire T2000 Server Service Manual, p/n 819-2548

Sun SPARC Enterprise T2000 Server Service Manual, p/n 819-7989