Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-1012360.1
Update Date:2018-03-01
Keywords:

Solution Type  Technical Instruction Sure

Solution  1012360.1 :   How to determine which systems have ILOM/ALOM4v/ALOM/LOM/ELOM/SP/XSCF or RSC ?  


Related Items
  • Sun Fire V215 Server
  •  
  • SPARC S7-2
  •  
  • SPARC T4-2
  •  
  • Sun Fire X4150 Server
  •  
  • Sun Netra T5440 Server
  •  
  • Sun Fire T1000 Server
  •  
  • Sun Fire X2200 M2 Server
  •  
  • Sun Blade X6450 Server Module
  •  
  • Sun Blade X6240 Server Module
  •  
  • Sun Fire V240 Server
  •  
  • SPARC M5-32
  •  
  • Sun Fire V245 Server
  •  
  • SPARC T7-1
  •  
  • Sun Fire X4200 Server
  •  
  • Sun SPARC Enterprise T5440 Server
  •  
  • Sun Blade T6300 Server Module
  •  
  • Sun Fire T2000 Server
  •  
  • Sun Fire V445 Server
  •  
  • SPARC T3-2
  •  
  • Sun Blade X6220 Server Module
  •  
  • Sun Fire V490 Server
  •  
  • Sun Fire V250 Server
  •  
  • Sun Fire V480 Server
  •  
  • Sun Fire V125 Server
  •  
  • Sun Blade X6440 Server Module
  •  
  • Sun Fire X4600 M2 Server
  •  
  • Sun Fire V440 Server
  •  
  • SPARC T8-1
  •  
  • SPARC T8-2
  •  
  • Sun Netra 440 Server
  •  
  • Sun Blade X6270 Server Module
  •  
  • SPARC T5-8
  •  
  • Sun SPARC Enterprise T5120 Server
  •  
  • Sun Server X3-2
  •  
  • Sun Fire X4200 M2 Server
  •  
  • Sun Netra T2000 Server
  •  
  • SPARC T3-4
  •  
  • Sun Fire V880z Visualization Server
  •  
  • Sun Server X3-2L
  •  
  • Sun Fire V210 Server
  •  
  • SPARC T7-2
  •  
  • SPARC T7-4
  •  
  • Sun SPARC Enterprise T5220 Server
  •  
  • SPARC T4-1
  •  
  • Sun Server X2-8
  •  
  • Sun Fire X4450 Server
  •  
  • Sun Fire V880 Server
  •  
  • Sun Fire X2100 M2 Server
  •  
  • Sun Fire X4270 M2 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Blade X6275 Server Module
  •  
  • SPARC T8-4
  •  
  • Sun Fire X4250 Server
  •  
  • SPARC T4-4
  •  
  • SPARC T5-2
  •  
  • SPARC T5-4
  •  
  • Sun SPARC Enterprise T5240 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Blade X3-2B
  •  
  • Sun Fire X4100 M2 Server
  •  
  • SPARC T3-1
  •  
  • Sun Blade X6250 Server Module
  •  
  • Sun Blade X6420 Server Module
  •  
  • Sun Fire X4100 Server
  •  
  • Sun Blade T6320 Server Module
  •  
  • Sun Blade T6340 Server Module
  •  
  • Sun Fire X4600 Server
  •  
  • Sun Netra T5220 Server
  •  
  • Sun Fire V890 Server
  •  
  • Sun SPARC Enterprise T5140 Server
  •  
  • Sun Fire X4170 M2 Server
  •  
  • Sun Server X2-4
  •  
  • SPARC S7-2L
  •  
  • Sun Fire X4500 Server
  •  
  • Sun SPARC Enterprise T2000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Usx/Blade/Netra>SN-SPARC: USx
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Blade Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>NEBS-Certified Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Midrange Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>Entry-Level Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Specialized Systems>Grid Systems
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>x64 Servers
  •  
  • _Old GCS Categories>Sun Microsystems>Servers>CMT Servers
  •  

PreviouslyPublishedAs
217050


Applies to:

Sun Blade X6220 Server Module - Version Not Applicable and later
Sun Blade X6450 Server Module - Version Not Applicable and later
Sun Fire V240 Server - Version Not Applicable and later
Sun Netra 440 Server - Version Not Applicable and later
Sun Blade T6300 Server Module - Version Not Applicable and later
All Platforms

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community, SPARC Legacy Servers.




Goal

This document describes which systems have either:

Lights Out Manager (LOM)

Advanced LOM (ALOM)

Advanced LOM for Solaris[TM] Sun4v kernel architecture (ALOM4v)

Integrated Lights Out Manager (ILOM)

Embedded Lights Out Manager (ELOM)

Sun[TM] Remote System Console (RSC) for system management

Embedded Service Processor (SP)

eXtended System Controller Facility (XSCF)

Solution

Please refer to the following resources:

Sun[TM] System Handbook References:

BootPROM_x86_x64

BootPROM_UltraSPARC_I_II

LOM

Sun Netra[TM] X1
Sun Netra[TM] T1400/1405
Sun Netra[TM] T1 AC200
Sun Netra[TM] T1 DC200
Sun Fire [TM] V100
Sun Fire[TM] V120
Sun Netra[TM] 20
Sun Netra[TM] 1280 **
Sun Netra[TM] 1290 **
Sun Fire[TM] V1280 **
Sun Fire[TM] E2900 **

** The LOM for the Sun Fire[TM] V1280/E2900 is delivered as part of the ScApp.

See the Hardware/PROM: 5.20.16: Sun Fire E6900/E4900/E2900/6800/4800/4810/3800/V1280 Netra 1280 and Netra 1290 Systems FW Update

ALOM

Sun Fire[TM] V125
Sun Fire[TM] V210
Sun Fire[TM] V215
Sun Fire[TM] V240
Sun Fire[TM] V245
Sun Fire[TM] V250
Sun Fire[TM] V440
Sun Fire[TM] V445

For ALOM reference, please see: How To Upgrade ALOM version and Related FAQ for V125, V210, V215, V240, V245, V250, V440, V445 and Netra 210, 240, 440 Servers (Doc ID 1001828.1)

ALOM4v

Sun Fire[TM] T1000
Sun Fire[TM] T2000
Sun SPARC[TM] Enterprise T1000
Sun SPARC[TM] Enterprise T2000
Sun Netra[TM] T2000
Sun Blade[TM] T6300

ILOM

Sun Fire[TM] X4100
Sun Fire[TM] X4170 M2
Sun Fire[TM] X4170 M3 (Sun Server X3-2)
Sun Fire[TM] X4200
Sun Fire[TM] X4270 M2

Sun Fire[TM] X4150
Sun Fire[TM] X4250

Sun Fire[TM] X4450

Sun Fire[TM] X4270 M3 (Sun Server X3-2L)
Sun Fire[TM] X4470 M2(Sun Server X2-4)
Sun Fire[TM] X4500
Sun Fire[TM] X4600
Sun Fire[TM] X4100 M2
Sun Fire[TM] X4200 M2
Sun Fire[TM] X4600 M2
Sun Fire[TM] X4800 M2 (Sun Server X2-8)
Sun Blade[TM] 6000 CMM
Sun Blade[TM] 8000 CMM
Sun Netra[TM] X4200 M2
Sun Blade [TM] X6220
Sun Blade[TM] X6240 Server Module
Sun Blade[TM] X6220 Server Module
Sun Blade[TM] X6275 Server Module
Sun Blade[TM] X6270 Server Module
Sun Blade[TM] X6270 M3 (Sun Blade X3-2B) Server Module
Sun Blade [TM] X6440 Server Module
Sun SPARC Enterprise[TM] T5140 - ILOM 2.x or 3.x + ALOM4v emulation
Sun SPARC Enterprise[TM] T5240 - ILOM 2.x or 3.x + ALOM4v emulation
Sun SPARC Enterprise[TM] T5440 - ILOM 2.x or 3.x + ALOM4v emulation
Sun SPARC[TM] Enterprise T5120
Sun SPARC[TM] Enterprise T5220
Sun Blade[TM] T6340 Server Module - ILOM 2.x or 3.x + ALOM4v emulation
Sun Blade[TM] T6320

SPARC T3-1
SPARC T3-2
SPARC T3-4
SPARC T4-1
SPARC T4-2
SPARC T4-4

SPARC T5-2
SPARC T5-4
SPARC T5-8

SPARC T7-1
SPARC T7-2
SPARC T7- 4

SPARC S7-2
SPARC S7-2L

SPARC T8-1
SPARC T8-2
SPARC T8- 4

SPARC M5-32
SPARC M6- 32

SPARC M7-8
SPARC M7-16
SPARC M8- 8

For M5-32 & M6-32 reference to: SPARC M5-32 and M6-32 Servers: Minimum supported Firmware, Software and Solaris patches page (Doc ID 1539275.1)

ELOM

Sun Fire[TM] X2100 M2
Sun Fire[TM] X2200 M2
Sun Fire[TM] X4150 (early releases)
Sun Fire[TM] X4450
Sun Blade X6250 Server Module - ELOM (no longer updated), ILOM 2.x or 3.x
Sun Blade X6450 Server Module - ELOM (no longer updated) ILOM 2.x or 3.x

RSC

Sun Fire[TM] V890
Sun Fire[TM] V490
Sun Fire[TM] V880
Sun Fire[TM] V480
Sun Fire[TM] 280R
Sun Enterprise[TM] 250

For RSC reference see: Sun Enterprise[TM] 250 server, Sun Fire[TM] 280R, V480/V490 and V880/V890 servers: Quick Cross Reference for RSC (Remote System Control) Patch/firmware (Doc ID 1003522.1)

SP
Sun Fire [TM] V20z
Sun Fire[TM] V40z

XSCF

Sun SPARC Enterprise[TM] M3000
Sun SPARC Enterprise[TM] M4000
Sun SPARC Enterprise[TM] M5000
Sun SPARC Enterprise[TM] M8000
Sun SPARC Enterprise[TM] M9000-32
Sun SPARC Enterprise[TM] M9000-64

Please reference Doc 1002631.1

 

Fujitsu M10-1
Fujitsu M10- 4
Fujitsu M10-4S
Please reference Doc 1554086.1

 

Fujitsu M10 PCI Expansion Unix
Please reference Doc 1924671.1

 

Reference Manuals


Reference for Firmware release history per Platform, please see: http://www.oracle.com/technetwork/systems/patches/firmware/release-history-jsp- 138416.html

All available from http://www.oracle.com/technetwork/indexes/docum entation/index.html

A good place to start is Managing Sun Systems - Sun Integrated Lights Out Manager

ALOM HowTos:

<Document: 1004884.1> How to configure the "NET MGT" port (ALOM Advanced Lights Out Manager Ethernet
<Document: 1009021.1>  How to configure the ALOM Notification Variables

Advanced Lights Out Manager (ALOM) Download Instructions:

- Login to MOS and go to the Patches & Updates tab.
- In the patch search field click on Product or Family
- In the product field put in 'Advanced Lights Out Manager' and click the search button.
- The next page will provide a patch name 10263984
- Click the patch number 10263984 and the page will show a button for Download
- Click 'Download' and obtain the file shown: p10263984_160_Generic.zip
- Unzip the file, it will provide the following firmware:
* ALOM_1.6.10_fw_hw0.tar.gz - ALOM 1.6.10 Firmware for Sun Fire V125, V210, V240, V250, V440, and Netra 210, 240 and 440
* ALOM_1.6.10_fw_hw8.tar.gz - ALOM 1.6.10 Firmware for Sun Fire V215, V245 and V445

RSC

RSC Software Download and Installation Instructions

RSC Software Download (steps to download the latest RSC software):

1. Login to MOS and select "Patches and Updates Tab"
2. In "Patch Search" on the Top right panel, Click on "Product or Family (Advanced Search)"
3. In the "Product Is" pull-down select "Sun remote System Control"??
4. In the next pull down "Release is" select the RSC version (2.2.2 or 2.2.3).
5. Select OS and click "Search" (will get a list with RSC releases & patches)
6. Select the desired RSC Release (packages) or patch  
7. Click Download on the Right

The packages for Solaris 8 and 9 (and later) are both in the zip file. There are two options of the zip file, 32bit, and 64bit, but they both have the same checksums, so there are no differences: p10264452_223_SOLARIS64.zip (p10264451_223_SOLARIS.zip)

Sun Remote System Control (RSC) for Sun Enterprise 250, Sun Fire 280R, Sun Fire V480, Sun Fire V490, Sun Fire V880, and Sun Fire V890 Servers

Sun Remote System Control (RSC) Installation Guide

Sun Remote System Control (RSC) Users Guide

 

SP

Sun Fire V20z and Sun Fire V40z Servers--Server Management Guide

 

XSCF

Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 XSCF Control Package (XCP) Firmware Image Software Version Matrix Information (Doc ID 1002631.1)
Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL): XCP FAQs (Doc ID 1393702.1)

Documentation:
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Administration Guide


RSC, LOM, ILOM, ALOM, ELOM, NET MGT, V890, V490, V880, V440, V250, V124, V215, V245, V445V240, V210, V1280, E2900, V120, V100, Netra T1 DC200, Netra T1 AC200, Netra X1, V480, 280R, Enterprise 250, sys_eventlevel, mgt_mailalert, T2000, T1000, X4100, X4200, X4500, X4600, X2100 M2, X2200 M2, T6300, T6320, X6220, X6250, X6450
Previously Published As
81146

Change History
Date: 2009-12-16
User Name: 79977
Action: Currency check
Comment: Updated/checked - Alan Nicolas, John Adams
Date: 2007-10-30
User Name: 97961
Action: Approved
Comment: Publishing. No further edits required.
Version: 30
Date: 2007-10-30
User Name: 97961
Action: Accept
Comment:
Version: 0
Date: 2007-10- 30
User Name: 114416
Action: Approved
Comment: good doc ok to publish
Version: 0

References

<NOTE:1009021.1> - How To Configure the ALOM Notification Variables
<NOTE:1004884.1> - How To Configure the ALOM "NET MGT" Port for Sun Fire V125, V210, V215, V240, V245, V250, V440, V445 and Netra 210, 240, 440 Servers
<NOTE:1539275.1> - SPARC M5-32 and M6-32 Servers: Minimum supported Firmware, Software and Solaris patches page
<NOTE:1012645.1> - How to Collect ALOM Data from the OS on T1000/T2000 Servers

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback