How to Remove and Replace a Sun Fire T2000 Rear Fan Tray:ATR:1174:0 [Video]
Related Items |
- Sun Fire T2000 Server
- Sun SPARC Enterprise T2000 Server
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SPARC-CAP VCAP
- Microlearning>Video>ML-VID-VCAP
|
In this Document
Applies to:
Sun SPARC Enterprise T2000 Server - Version Not Applicable and later
Sun Fire T2000 Server - Version Not Applicable and later
Information in this document applies to any platform.
Goal
How to Remove and Replace a Sun Fire T2000 Rear Fan Tray
*************************************************************************************
To report errors or request improvements on this procedure, please Add a comment on Doc ID: 1307834.1
*************************************************************************************
Solution
DISPATCH INSTRUCTIONS
WHAT SKILLS ARE REQUIRED:
No special skills required, Customer Replaceable Unit (CRU) procedure
TIME ESTIMATE: 120 minutes
TASK COMPLEXITY: 0
REMOVAL/REPLACEMENT INSTRUCTIONS:
PROBLEM OVERVIEW: faulty Rear Blower
WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? :
DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc. If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
The rear blower on the server is hot-swappable.
WHAT ACTIONS ARE REQUIRED:
1. Gain access to the rear of the server where the faulty blower unit is located.
2. Release the cable management arm tab and swing the cable management arm out of the way so you can access the power supply.
3. Unscrew the two thumbscrews that secure the rear blower to the chassis.
4. Grasp the thumbscrews and slowly slide the blower out of the chassis, keeping the blower level as you remove it.
5. Unpackage the replacement blower.
6. Slide the blower into the chassis until it locks into the power connector at the front of the blower compartment
7. Tighten the two thumbscrews to secure the blower to the chassis.
8. Verify that the Rear Blower and Service Required LEDs are not lit.
9. Close the CMA, inserting the end of the CMA into the rear left rail bracket.
OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTIONS ARE REQUIRED TO RETURN THE SYSTEM TO AN OPERATIONAL STATE:
N/A (hot-swappable procedure)
SPECIAL INSTRUCTIONS:
When replacing a fan, it is important to know, how to distinguish between a CPU/front fan and a Rear fan (blower).
The CPU fans will be reported as FT0/FMx (x= 0,1,2) and the rear fan (blower) reported as FT2 (in prtdiag, showenvironment and ALOM logs).
- Output from "sc> showenvironment"
Fans Status:
---------------------------------------------------
Fans (Speeds Revolution Per Minute):
Sensor Status Speed Warn Low
---------------------------------------------------
FT0/FM0 OK 3650 -- 1920 <-- front CPU fan FM0
FT0/FM1 OK 3437 -- 1920 <-- front CPU fan FM1
FT0/FM2 OK 3586 -- 1920 <-- front CPU fan FM2
FT2 OK 2594 -- 1900 <-- Rear Blower
- Example of an error from the front (CPU) fan module FT0/FM2:
SC Alert: [ID 407631 daemon.error] SYS_FAN at FT0/FM2 has FAILED.
- Example of a Rear Blower (FT2) fan error:
SC Alert: [ID 602306 daemon.error] SYS_FAN at FT2 has FAILED.
PARTS NOTE:
Sun Fire T2000 https://support.oracle.com/handbook_private/Systems/SunFireT2000/components.html#Fan
Sun Fire T2000 (post July 2006) https://support.oracle.com/handbook_private/Systems/SunFireT2000_R/components.html#Fan
Sun Enterprise T2000 https://support.oracle.com/handbook_private/Systems/SE_T2000/components.html#Fan
Sun Fire T2000 Server Service Manual , p/n 819-2548:
Sun SPARC Enterprise T2000 Server Service Manual , p/n 819-7989