Problem Document
|
Synopsis
|
Last Modified Date
|
2235969.1 |
CELL-02827 - Bootable USB device with wrong size detected |
2018-05-23
|
2215807.1 |
exasw-ibs0 Broken Madrpc_init: Can't Open UMAD Port at ibswitches after switch upgrade |
2017-02-09
|
2112346.1 |
12cEM reports error on Exadata X2-8 or X3-8 ILOM targets: "Status Metric evaluation error start - oracle.sysman.emSDK.agent.fetchlet.exception.FetchletException: - Could be because of an invalid username/password" |
2016-03-02
|
2076283.1 |
Engineered Systems: 300GB, 600GB, 900GB and 1.2TB Disk Firmware Upgrade to Address Unrecoverable Read Errors |
2017-08-18
|
1988445.1 |
ibqueryerrors Reports SymbolErrors on One or More of the IB switch or HCA port |
2018-05-23
|
1988202.1 |
Engineered Systems May Show: ERROR: Wrong fan 0 status : nr |
2017-01-18
|
1931131.1 |
The disks and disk backplane are being recognized through the HBA (LSI BIOS) but are not being recognized through the systemboard's I2C bus. |
2014-11-18
|
1905132.1 |
Exadata: ASM start fails with ORA-56865 due to mismatch in MTU interfaces |
2014-10-09
|
1673886.1 |
Error after SAS RAID Firmware upgrade - "FW could not sync up config/prop changes for some of the VD's/PD's Press any key to continue, or 'C' to load the configuration utility." |
2014-06-16
|
1663205.1 |
Exadata: Exacheck 2.2.4 Report Tune2fs Check Interval & Maximum Mount Count" shows Bad Magic number in Super-Block while trying to open |
2014-04-17
|
1634742.1 |
Exachk Reports Master (Rack) Serial Number Does Not Match for Exadata |
2014-06-26
|
1633947.1 |
Exadata: Downgrading IB switches fail with Error messages: [FAIL ] controlled_handover must be TRUE, value in /etc/opensm/opensm.conf is FALSE . ACTION: Correct or add controlled_handover in /etc/opensm/opensm.conf |
2014-03-17
|
1632787.1 |
Oracle Hardware Management Pack (OHMP) is not needed on Exadata |
2015-10-27
|
1624055.1 |
Exadata: Cell Boot Usb Partition: Not Found |
2014-03-11
|
1620735.1 |
Symbol Errors Increasing On Infiniband Switch |
2017-11-09
|
1585910.1 |
Exadata: No kdump initial ramdisk found. [WARNING] - no record for 'dm-0' in database |
2014-08-27
|
1585356.1 |
Different Checksum(md5sum) For The Oracle Binaries In Two Different Nodes Of An Exadata Rack. |
2013-09-24
|
1583297.1 |
Exadata: RDS Performance Degrades when Database is in Timezone Upgrade Mode |
2013-09-26
|
1580407.1 |
File System "/" has Exceeded 80% in Exadata Cell node |
2014-01-17
|
1577623.1 |
X3-2L (12 disk) service label on the cover of all X3-2L systems shipped to date have an incorrect SAS expander to DBP and Rear HDD's cabling diagram. |
2013-08-27
|
1577344.1 |
OS Watcher is Taking Huge Space on Database Server |
2014-03-14
|
1577013.1 |
Exadata: Large trace Files On Physical Standby |
2013-09-26
|
1573414.1 |
The sensor metrics in ibswitch collection fails with: Can't get query descriptor or execution descriptor |
2015-01-15
|
1572353.1 |
showunhealthy reports Error on I2C |
2015-11-17
|
1568509.1 |
Sun Rack II PDU ( Power Distribution Unit ) Network auto negotiation issues. |
2016-10-25
|
1544182.1 |
EXADATA HW: High Temperature (CL_TEMP) Alert From One Of The Cell Nodes |
2015-12-08
|
1540613.1 |
Mismatched Flashdisk names found from the list celldisk detail command for 3 flashdisks in cell02 |
2013-07-24
|
1529290.1 |
Exadata Storage Server gives a warning of unsupported firmware during boot if mixed Flash F40 firmware is installed |
2014-02-10
|
1514940.1 |
12c: Red Arrow Down Status on IB ports or False Alert "Cable Is Present On Port 'N' But It Is Polling For Peer Port" |
2017-03-14
|
1502577.1 |
Exadata: ORA-00600 :[25027] On Update Over Compressed Table (EHCC) |
2014-02-07
|
1487790.1 |
Exadata: ILOM COMMANDS FAILED WITH "SUN OEM CLI COMMAND FAILED" |
2014-03-25
|
1479863.1 |
Rationale Behind The Group Used On Directories Created By The Exadata BCU Script |
2012-08-03
|
1458626.1 |
ASM In Hung State Across All Nodes In Exadata Server |
2018-05-29
|
1451026.1 |
ASR SNMP Trap Destination and Enterprise Manager on Exadata Cell Nodes |
2017-05-17
|
1379750.1 |
Routine Query Becomes Terribly Slow Over Time with High PX_MISMATCH. |
2012-08-22
|
1312264.1 |
Foreign configuration(s) found on adapter while node bootup |
2015-06-16
|
1300504.1 |
Intermittent ORA-12514 on Exadata RAC Database Server 11.2 |
2012-10-30
|
1200103.1 |
Completed addnode in Exadata DB Machine but CRS fails to start after running root.sh |
2013-12-20
|
1113003.1 |
HALRT-02002: System hard disk predictive failure |
2016-11-08
|