Solution Type Problem Resolution Sure Solution 1572353.1 : showunhealthy reports Error on I2C
In this Document
Applies to:Exadata Database Machine V2 - Version All Versions to All Versions [Release All Releases]Sun Datacenter InfiniBand Switch 36 - Version Not Applicable to Not Applicable [Release N/A] Exalogic Elastic Cloud X3-2 Hardware - Version All Versions to All Versions [Release All Releases] Exalogic Elastic Cloud X3-2 Half Rack - Version All Versions to All Versions [Release All Releases] Exalogic Elastic Cloud X3-2 Full Rack - Version All Versions to All Versions [Release All Releases] Linux x86-64 SymptomsLogin to the switch ILOM -> cd /SYS/Fabric_Mgmt -> ls FabMan@localhost->showunhealthy Error on I2C read i2caddr = b4, reg 5e, status = -1, errno = No such device or address OK - No unhealthy sensors FabMan@localhost-> SUN DCS 36p version: 1.3.3-2 Build time: Apr 4 2011 11:15:19 SP board info: Manufacturing Date: 2012.12.27 Serial Number: "#######" Hardware Revision: 0x0007 Firmware Revision: 0x0000 BIOS version: SUN0R100 BIOS date: 06/22/2010 FabMan@localhost->env_test Environment test started: Starting Environment Daemon test: Environment daemon running Environment Daemon test returned OK Starting Voltage test: Voltage ECB OK Measured 3.3V Main = 3.27 V Measured 3.3V Standby = 3.39 V Measured 12V = 12.09 V Measured 5V = 4.99 V Measured VBAT = 3.03 V Measured 2.5V = 2.50 V Measured 1.8V = 1.78 V Measured I4 1.2V = 1.22 V Voltage test returned OK Starting PSU test: Error on I2C read i2caddr = b4, reg 5e, status = -1, errno = No such device or address <<<<<<<<< PSU 0 present PSU 1 present OK PSU test returned OK Starting Temperature test: Back temperature 29 Front temperature 28 SP temperature 54 Switch temperature 52, maxtemperature 54 Temperature test returned OK Starting FAN test: Fan 0 not present Fan 1 running at rpm 12753 Fan 2 running at rpm 12644 Fan 3 running at rpm 12644 Fan 4 not present FAN test returned OK Starting Connector test: Connector test returned OK Starting Onboard ibdevice test: Switch OK All Internal ibdevices OK Onboard ibdevice test returned OK Environment test PASSED CausePS0 was poorley seated. Solution1) reseat both power supplies 2) If problem is still present, swap slots. IE: move ps0 to ps1 slot and ps1 to ps0 slot -If problem follows PS0 to the new slot then replace the PS -If the problem remains with slot 0, then the switch will likely need to be replaced. Attachments This solution has no attachment |
||||||||||||||||
|