![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1988202.1 : Engineered Systems May Show: ERROR: Wrong fan 0 status : nr
In this Document
Created from <SR 3-10282883011> Applies to:Big Data Appliance X4-2 Hardware - Version All Versions and laterExadata X3-2 Hardware - Version All Versions and later Exadata X5-2 Hardware - Version All Versions and later Exadata X3-8 Hardware - Version All Versions and later Exadata X4-2 Hardware - Version All Versions and later Linux x86-64 SymptomsRunning bdacheckcluster shows a fan hardware failure on one of the nodes of Oracle Big Data Appliance (BDA). Running bdacheckhw on the BDA shows: ERROR: Wrong fan 0 status : nr
INFO: Expected fan 0 status : ok Note: This may also occur on other Engineered Systems as well such as Exadata.
Logging into the ILOM CLI and trying to clear the fault only clears it for a few seconds: 1. View the fault: -> show faulty
2. Clear the fault: -> set /SYS/MB/FM0 clear_fault_action=true
CauseThis is caused by a faulty fan part. SolutionThe fan must be replaced. Open a service request to have the fan replaced by a field engineer. Attachments This solution has no attachment |
||||||||||||||||
|