Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1620735.1
Update Date:2017-11-09
Keywords:

Solution Type  Problem Resolution Sure

Solution  1620735.1 :   Symbol Errors Increasing On Infiniband Switch  


Related Items
  • Exadata X3-8 Hardware
  •  
  • Exadata X4-2 Hardware
  •  
  • Exadata X5-2 Hardware
  •  
  • Exalogic Elastic Cloud X5-2 Hardware
  •  
  • Oracle SuperCluster T5-8 Hardware
  •  
  • Oracle Fabric Interconnect F1-15
  •  
  • Exalogic Elastic Cloud X4-2 Hardware
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
  • Big Data Appliance X3-2 Hardware
  •  
  • Big Data Appliance X4-2 Hardware
  •  
  • Exadata X3-2 Hardware
  •  
  • Exadata Database Machine X2-8
  •  
  • Exalogic Elastic Cloud X3-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-8411668212>

Applies to:

Exadata X5-2 Hardware - Version All Versions to All Versions [Release All Releases]
Exalogic Elastic Cloud X3-2 Hardware - Version X3 to X3 [Release X3]
Exalogic Elastic Cloud X4-2 Hardware - Version X4 to X4 [Release X4]
Big Data Appliance X3-2 Hardware - Version All Versions to All Versions [Release All Releases]
Oracle SuperCluster T5-8 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Symbol errors are increasing as seen in the repeated output of  ibcheckerrors:

IBswitch2# ibcheckerrors

Errors for 0x10e00001293922 "db04 S 192.168.10.48 HCA-4"
GUID 0x10e00001293922 port 2: [SymbolErrors == 18154] [LinkRecovers == 9] [LinkDowned == 1]

 

 

Changes

Infiniband cables / connectors in the datacenter may have been disturbed or moved

Cause

Poorly seated Infiniband cable on either the switch port end or the host HCA end

Solution

In this case, the cable needed to be re-seated by a Field Engineer on HCA-4 port 2 on db04.

Suggest to run the following command to set counters to "0" and monitor after re-seating the cable:

  IBswitch2# ibclearerrors

 

 

Guidelines for the threshold number of errors per hour, are given in the Administration Guide for Oracle Infiniband Switch:

Note - According to the InfiniBand specification 10E-12 BER, the maximum allowable symbol error rate is 120 errors per hour.

 

References

<NOTE:1449226.1> - Exachk Health-Check Tool for Exalogic
<NOTE:1448073.1> - Engineered Systems Upgrade/Supportability Reference Doc (INTERNAL ONLY)
http://www.oracle.com/technetwork/documentation/oracle-net-sec-hw-190016.html

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback