![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1312264.1 : Foreign configuration(s) found on adapter while node bootup
Applies to:Oracle Exadata Storage Server Software - Version 11.1.3.1.0 and laterOracle Exadata Hardware - Version 11.2.0.1 and later Exadata Database Machine V2 - Version All Versions and later Exadata Database Machine X2-2 Hardware - Version All Versions and later Exadata Database Machine X2-8 - Version All Versions and later Information in this document applies to any platform. SymptomsNode did not come after recycle. checking the status through ILOM remote console,it was stuck with below message. LSI MegaRAID SAS-MFI BIOS Version 3.09.00 (Build August 27, 2009)
Copyright(c) 2009 LSI Corporation HA -0 (Bus 19 Dev 0) LSI MegaRAID SAS 9261-8i FW package: 12.0.1-0081 Foreign configuration(s) found on adapter Press any key to continue or 'C' load the configuration utility, or 'F' to import foreign configuration(s) and continue. There are offline or missing virtual drives with preserved cache. Please check the cables and ensure that all drives are present. Press any key to enter the configuration utility.
CauseWhen a controller firmware detects a physical disk with existing foreign metadata, it flags the physical disk as foreign and generates an alert indicating that a foreign disk was detected. SolutionPress 'C' at "Foreign configuration(s) found on adapter" screen. Attachments This solution has no attachment |
||||||||||||
|