Solution Type  Problem Resolution Sure

Solution  1487790.1 :   Exadata: ILOM COMMANDS FAILED WITH "SUN OEM CLI COMMAND FAILED"  


Related Items
  • Exadata X3-2 Hardware
  •  
  • Exadata Database Machine X2-8
  •  
  • Oracle Exadata Hardware
  •  
  • Exadata X3-8 Hardware
  •  
  • Exadata Database Machine X2-2 Hardware
  •  
  • Exadata Database Machine V2
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Created from <SR 3-6112201821>

Applies to:

Exadata Database Machine V2 - Version All Versions and later
Oracle Exadata Hardware - Version 11.2.0.3 and later
Exadata Database Machine X2-2 Hardware - Version All Versions and later
Exadata Database Machine X2-8 - Version All Versions and later
Exadata X3-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Failed to run "/usr/bin/ipmitool sunoem cli force "show /SP/alertmgmt/rules/1""
  Sun OEM cli command failed
[root@xbkpdb02 ~]# /usr/bin/ipmitool sunoem cli force "show /SP/alertmgmt/rules/1"
Sun OEM cli command failed

Cause

The issue is because of the bug.
<Bug 13590125> - ILOM COMMANDS FAILED WITH "SUN OEM CLI COMMAND FAILED"

 

Solution

Fix for <Bug 13590125> is included in 11.2.3.2.0

Workaround is to Reset the ilom (ipmitool mc reset cold)

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback