[F] = Field Replaceable Unit (FRU) [C] = Customer Replaceable Unit (CRU) [A] = Alternate, can be used in system; wasn't used during production [S] = Supported, but can no longer be ordered with this system [N] = No longer supported for this system Price = Price this Part
3 12-Slot Disk Backplane PN#541-4363 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 4 12-Slot Disk Backplane PN#541-4363 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 5 12-Slot Disk Backplane PN#541-4363 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 6 12-Slot Disk Backplane PN#7049238 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
7 2TB - 7200 RPM SAS Disk Assembly PN#542-0247 is used in the Sun Fire X4270 M2 as part of the High Capacity Oracle Exadata Storage Expansion Rack X2-2. 8 600GB - 15000 RPM SAS Disk Assembly PN# 542-0428 is used in the Sun Fire X4270 M2 as part of the High Performance Oracle Exadata Storage Expansion Rack X2-2. 9 3TB - 7200 RPM SAS Disk Assembly PN# 7010036 is used in the Sun Fire X4270 M2 as part of the High Capacity Oracle Exadata Storage Expansion Rack X2-2. 10 The 8TB Disk is not supported in 12-Slot 3.5" Disk Cage Assembly 7077819. The 8TB Disk requires Disk Cage Assembly 7310384. NOTE: Using 2TB Disk Assembly PN#7040582 requires minimum Exadata image of 11.2.2.4.1 or later. Refer to Note 1416303.1 for more details. NOTE: 3TB Disk Assembly PN#7010036 requires a minimum Exadata image of 11.2.2.4.2 or later. Refer to Note 1416303.1 for more details. NOTE: 600GB Disk Assembly PN#542-0166 is required if using Exadata image 11.2.2.4.0 or earlier.
Refer to Note 1416303.1 for more details. NOTE: 2TB Disk Assembly PN#F542-0247 is required if using Exadata image 11.2.2.4.0 or earlier. Refer to Note 1416303.1 for more details.
11 Fan Board Assembly PN#541-4124 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 12 Fan Assembly PN#541-4222 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
13 x8/x8 PCI Express Riser Assembly PN#541-2884 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 14 x8/x8 Switched PCI Express Riser Assembly PN#541-3356 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 15 x8/x8 PCI Express Riser Assembly PN#541-2884 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 16 x8/x8 PCI Express Riser Assembly PN#7049269 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 17 x8/x8 Switched PCI Express Riser Assembly PN#541-3356 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 18 x8/x8 Switched PCI Express Riser Assembly PN#7049272 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
20 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 21 1200 Watt Power Supply, Type A249 PN#300-2235 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 22 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 23 1200 Watt Power Supply, Type A249 PN#300-2235 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 24 Power Distribution Assembly PN#541-4223 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
26 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 27 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 28 Fan 350-1566 is not a FRU (use 350-1312 or 7061031). 29 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267. 30 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267. 31 Fan 350-1566 is not a FRU (use 350-1312 or 7061031). 32 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267. 33 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
[F] = Field Replaceable Unit (FRU) [C] = Customer Replaceable Unit (CRU) [A] = Alternate, can be used in system; wasn't used during production [S] = Supported, but can no longer be ordered with this system [N] = No longer supported for this system Price = Price this Part
[F] = Field Replaceable Unit (FRU) [C] = Customer Replaceable Unit (CRU) [A] = Alternate, can be used in system; wasn't used during production [S] = Supported, but can no longer be ordered with this system [N] = No longer supported for this system Price = Price this Part
NS = Not Shown
Code
Manufacturing Part#
Description
NS
341-6222
Mounting Bracket
NS
371-2484
PDB Signal Cable
NS
530-3510
Interlock Switch Cable
NS
530-3892 34 [F]
4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm
34 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm PN#530-3892 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 35 Right Indicator Panel PN#541-4304 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 36 SAS Expander Assembly PN#541-4305 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 37 Left Indicator Panel PN#541-4371 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 38 SAS Expander Assembly PN#541-4305 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2. 39 SAS Expander Assembly PN#7055798 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.