This product is based on the Sun Fire X4170 and Sun Fire X4275 servers, but uses specialized components. Only use parts listed in the Oracle Exadata V2 Full Components List to service this product.

Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-3993 [F] Buy 3V Lithium Coin Cell Battery n/a
n/a 371-2210 2 [F] Buy 3V Lithium Coin Cell Battery n/a
2 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4300 [F] 2.53GHz Intel Quad-Core Xeon E5540, 8MB, 80W n/a
n/a 541-2545 3 [F] Xeon Heatsink n/a
  • 240-6751
  • Spring Screw
n/a
n/a 541-3310 4 [F] Xeon Heatsink w/Grease n/a
  • 240-6751
  • Spring Screw
n/a
  • 310-0211
  • Pre-greased Heatsink
n/a
3 Xeon Heatsink w/Grease PN#541-2545 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
4 Xeon Heatsink w/Grease PN#541-3310 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 350-1519 [F] Buy Serial Cable Kit n/a
  • 530-4424
  • USB to DB9M Serial Cable
n/a
  • 530-4425
  • DB9F to DB9F Null Modem Cable
n/a
n/a 530-4403 [F] 4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 2M n/a
n/a 530-4404 [F] 4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 3M n/a
n/a 530-4415 [F] 4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 5M n/a
n/a 530-4432 [F] Ethernet Cable, cat 5/5E, RJ45 to RJ45, 7' Blue n/a
n/a 530-4433 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Red n/a
n/a 530-4434 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Red n/a
n/a 530-4435 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Black n/a
n/a 530-4436 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Black n/a
n/a 530-4437 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Orange n/a
n/a 530-4438 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Orange n/a
n/a 560-2937 [F] X4275 Cable Kit n/a
  • 530-4245
  • 12-Slot Backplane Power Cable
n/a
  • 530-4246
  • 20-Pin Backplane I2C Cable
n/a
  • 530-4247
  • 6-Pin Fan Power Cable
n/a
  • 530-4248
  • 16-Pin FAN I2C Cable
n/a
n/a 7039990 [F] MPO to MPO High Bandwidth QSFP Optical Cable, 10M n/a
n/a 7039999 [F] MPO to MPO High Bandwidth QSFP Optical Cable, 20M n/a
n/a 7040001 [F] MPO to MPO High Bandwidth QSFP Optical Cable, 50M n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
n/a 375-3606 5 [F] Sun Dual Port 40Gb/sec 4x Infiniband QDR Host Channel Adapter PCI Express n/a
5 Sun Dual Port 40Gb/sec 4x Infiniband QDR Host Channel PCI Express Adapter PN#375-3606 is supported in PCIe slot 2 in the Sun Fire X4170 and PCIs slot 3 in the Sun Fire X4275 only as part of the Oracle Exadata V2.
Disk Backplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 511-1283 6 [F] 8-Slot Disk Backplane, SATA DVD n/a
n/a 541-3386 7 [F] 12-Slot Disk Backplane n/a
  • 350-1262
  • Mounting Bracket
n/a
  • 12-Slot Disk Backplane
n/a
n/a 7051678 [F] 8-Slot Disk Backplane, SATA DVD 511-1283 8 [F]
6 8-Slot Disk Backplane, SATA DVD PN#511-1283 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
7 12-Slot Disk Backplane PN#541-3386 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
8 8-Slot Disk Backplane, SATA DVD PN#511-1283 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
Disks
Option # Manufacturing
Part #
Description Previous
Part #
n/a 540-7868 9 [F] 146GB - 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST9146802SS [ST914602SSUN146G]
    (146GB - 10000 RPM - SAS Disk)
n/a
  • Hitachi HUC101414CSS300 [H101414SCSUN146G]
    (146GB - 10000 RPM - SAS Disk)
n/a
  • Seagate ST9146803SS [ST914603SSUN146G]
    (146GB - 10000 RPM - SAS Disk)
n/a
  • Hitachi HUC103014CSS600 [H103014SCSUN146G]
    (146GB - 10000 RPM - SAS Disk)
n/a
  • Marlin 2.5" Bracket
n/a
n/a 542-0166 10 [F] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 542-0167 11 [F] 2TB - 7200 RPM 3.5" SATA, Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi H7220AA30 [H7220AA30SUN2.0T]
    (2TB - 7200 RPM - SATA Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
n/a 542-0428 12 [F] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Hitachi HUS156060VLS600 [HUS1560SCSUN600G]
    (600GB - 15000 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket
n/a
9 146GB - 10000 RPM SAS SFF Disk Assembly with 1 bracket and 1 of the following disks PN#540-7868 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
10 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks PN#542-0166 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
11 2TB - 7200 RPM 3.5" SATA Disk Assembly with 1 bracket and 1 of the following disks PN#542-0167 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
12 600GB - 15000 RPM SAS Disk Assembly PN#542-0428 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
NOTE: 600GB Disk Assembly PN#542-0166 is required if using Exadata image 11.2.2.4.0 or earlier. Refer to Note 1416303.1 for more details.
NOTE: Using 600GB Disk Assembly PN#542-0428 requires minimum Exadata image of 11.2.2.4.1 or later. Refer to Note 1416303.1 for more details.
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2112 13 [F] Fan Power Board n/a
  • 330-4442
  • Top Bracket
n/a
  • 330-4443
  • Bottom Bracket
n/a
  • Fan Board
n/a
n/a 541-2802 14 [F] Fan Module n/a
  • 310-0164
  • 40mm 4-Pole Fan, Nidec
n/a
n/a 541-3290 15 [F] CPU Dual Fan Assembly w/ Metal Fingerguards n/a
  • 310-0210
  • Japan Servo Fan, 60×38mm, 2U
n/a
n/a 541-3394 16 [F] Fan Board Assembly n/a
  • 330-4940
  • Top Bracket
n/a
  • 350-1270
  • Bottom Bracket
n/a
  • 511-1239
  • Fan Board
n/a
n/a 7061031 [F] Rear-to-Front Airflow Fan Module 350-1312 [F] [S]
n/a 350-1312 [F] [S] Rear-to-Front Airflow Fan Module n/a
13 Fan Power Board PN#541-2112 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
14 Fan Module PN#541-2802 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
15 Fan Module PN#541-3290 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
16 Fan Board Assembly PN#541-3394 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
I/O
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2883 17 [F] 1-Slot x8 PCI Express Riser Assembly n/a
  • 1-Slot x8 PCI Express Riser
n/a
  • 541-2924
  • Riser Mounting Bracket
n/a
n/a 541-2884 18 [F] x8/x8 PCI Express Riser Assembly n/a
  • x8/x8 PCI Express Riser
n/a
  • 541-2531
  • Bracket
n/a
n/a 541-2885 19 [F] 1-Slot x16 PCI Express Riser Assembly n/a
  • 1-Slot x16 PCI Express Riser
n/a
  • 541-2924
  • Riser Mounting Bracket
n/a
n/a 541-3356 20 [F] x8/x8 Switched PCI Express Riser Assembly n/a
  • x8/x8 Switched PCI Express Riser
n/a
  • 541-2531
  • Bracket
n/a
n/a 7049269 [F] x8/x8 PCI Express Riser Assembly 541-2884 21 [F]
  • 541-2531
  • Bracket
n/a
  • 7049268
  • x8/x8 PCI Express Riser
501-7964
n/a 7049272 [F] x8/x8 Switched PCI Express Riser Assembly 541-3356 22 [F]
  • 541-2531
  • Bracket
n/a
  • 7049271
  • x8/x8 Switched PCI Express Riser
n/a
n/a 7049275 [F] 1-Slot x8 PCI Express Riser Assembly 541-2883 23 [F]
  • 541-2924
  • Riser Mounting Bracket
n/a
  • 7049274
  • 1-Slot x8 PCI Express Riser
n/a
    • 541-2924
    • Riser Mounting Bracket
n/a
n/a 7053384 [F] 1-Slot x16 PCI Express Riser Assembly 541-2885 24 [F]
  • 541-2924
  • Riser Mounting Bracket
n/a
  • 7053383
  • 1-Slot x16 PCI Express Riser
501-7965
17 1-Slot x8 PCI Express Riser Assembly PN#541-2883 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
18 x8/x8 PCI Express Riser Assembly PN#541-2884 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
19 1-Slot x16 PCI Express Riser Assembly PN#541-2885 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
20 x8/x8 Switched PCI Express Riser Assembly PN#541-3356 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
21 x8/x8 PCI Express Riser Assembly PN#541-2884 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
22 x8/x8 Switched PCI Express Riser Assembly PN#541-3356 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
23 1-Slot x8 PCI Express Riser Assembly PN#541-2883 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
24 1-Slot x16 PCI Express Riser Assembly PN#541-2885 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
Memory
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4288 [F] 4GB Registered DDR3-1333 DIMM n/a
n/a 371-4743 [F] 4GB USB 2.0 Flash Drive n/a
n/a 371-4966 [F] 8GB Registered DDR3L-1333/DDR3L-1600 DIMM, 1.35V n/a
NOTE: 8GB Registered DDR3-1333 DIMM PN#371-4966 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-1897 25 [F] Type A217 1050 Watt AC Input Power Supply n/a
n/a 300-2143 26 27 [F] Type A237 760 Watt AC Input Power Supply n/a
n/a 300-2233 [F] Type A247 760 Watt AC Input Power Supply 300-2143 28 29 [F]
n/a 300-2235 [F] Type A249 1100/1200 Watt AC Input Power Supply n/a
n/a 300-2299 [F] Type A247A 760 Watt AC Input Power Supply 300-2233 [F] 
n/a 501-7696 32 [F] Power Distribution Board n/a
n/a 541-2073 33 [F] Power Distribution Board/Bus Bar Assembly n/a
  • 341-3166
  • Bus Bar Left
n/a
  • 341-3167
  • Bus Bar Right
n/a
  • 371-2484
  • PDB Signal Cable
n/a
  • Horizontal Power Distribution Board
n/a
  • Vertical Power Distribution Board
n/a
25 1050 Watt Power Supply, Type A217 PN#300-1897 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
26 760 Watt Power Supply PN#s 300-2233/300-2143 are used in the Sun Fire X4170 as part of the Oracle Exadata V2.
27 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
28 760 Watt Power Supply PN#s 300-2233/300-2143 are used in the Sun Fire X4170 as part of the Oracle Exadata V2.
29 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
30 760 Watt Power Supply PN#s 300-2233/300-2143 are used in the Sun Fire X4170 as part of the Oracle Exadata V2.
31 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
32 Power Distribution Board PN#501-7696 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
33 Power Distribution Board/Bus Bar Assembly PN#541-2073 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
NOTE: 1050 Watt Power Supply PN#300-1897 is a previous part to the 1100/1200 Watt Power Supply PN#300-2235. (Reference e0007663)
Rack
Option # Manufacturing
Part #
Description Previous
Part #
n/a 180-2379 [F] 13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M n/a
n/a 180-2380 [F] 13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M n/a
n/a 350-1287 [F] 1U/2U Cable Management Arm n/a
n/a 350-1502 [F] 1U/2U Bolt-In Slide Rail Kit n/a
n/a 350-1514 Cable Management Arm Extension 1U/2U n/a
n/a 350-1521 [F] 1U Vented Filler Panel n/a
n/a 350-1546 [F] Cable Management Arm 1U n/a
n/a 350-1637 [F] 2 Way Service Upgrade Label (64x 267-4850) n/a
n/a 350-1638 [F] 3 Way Service Upgrade Label (96x 267-4850) n/a
n/a 350-1639 [F] 4 Way Service Upgrade Label (128x 267-4850) n/a
n/a 350-1640 [F] 5 Way Service Upgrade Label (160x 267-4850) n/a
n/a 350-1641 [F] 6 Way Service Upgrade Label (192x 267-4850) n/a
n/a 350-1642 [F] 7 Way Service Upgrade Label (224x 267-4850) n/a
n/a 350-1643 [F] 8 Way Service Upgrade Label (256x 267-4850) n/a
n/a 371-2741 [F] 1U/2U Screw-Mount Slide Rail Rackmount Kit, 730mm n/a
n/a 371-3995 [F] 15KVA Three-Phase PDU, North America n/a
n/a 371-4000 [F] 15KVA Three-Phase PDU, International n/a
n/a 371-4199 [F] 15KVA Single-Phase PDU, North America n/a
n/a 371-4201 34 [F] Buy 15KVA Single-Phase PDU, International n/a
n/a 371-4976 [F] 15KVA Three-Phase PDU, International 371-4000 [F]
n/a 599-3667 Sun Oracle Database Machine Rack n/a
  • 594-6413
  • Rack with Heavy Duty Pallet
n/a
    • 371-4766
    • 42U-1200 Rack
n/a
n/a 7015399 [F] 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M 180-2379 [F]
n/a 7015400 [F] 10A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M 180-2380 [F]
n/a 7051805 [F] 15KVA Single-Phase PDU, North America 371-4199 [F]
n/a 7051908 [F] 15KVA Three-Phase Power Distribution Unit (PDU), North America 371-3995 [F]
n/a 7051914 [F] 15KVA Three-Phase Power Distribution Unit (PDU), International 371-4976 [F] 
34 22KVA Single-Phase PDU, HV PN#371-5040 can be used in place of the 15KVA Single-Phase PDU, International PN#371-4201 due to FRU stock shortages.
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4415 [F] 24GB Solid State Flash Memory Module n/a
n/a 371-4982 [F] 6Gbps SAS-2 RAID PCI Battery Module, BBU08 371-4746 [F]
n/a 375-3644 35 [F] 8-Port 6Gbps SAS-2 RAID PCI Express HBA, B2 ASIC n/a
n/a 375-3701 [F] 8-Port 6Gbps SAS-2 RAID PCI Express HBA, B4 ASIC 375-3644 36 [F]
n/a 541-3731 38 96GB PCI Express Flash Accelerator F20 SAS HBA n/a
  • Energy Storage Module (ESM)
n/a
  • PCI Express Flash Board
511-1275 [F] [S]
  • 24GB Solid State Flash Memory Module, FW D21Y
371-5014 [F] 
n/a 541-4417 39 96GB PCI Express Flash Accelerator F20 M2 1.1 SAS HBA n/a
  • Energy Storage Module (ESM) [SKU]
n/a
  • 24GB Solid State Flash Memory Module, FW D20Y
n/a
  • PCI Express Flash Board
n/a
n/a 7018497 [F] Energy Storage Module (ESM) (Qty #4) Kit [SKU] n/a
  • Energy Storage Module (ESM)
n/a
n/a 7018498 [F] Energy Storage Module (ESM) (Qty #12) Kit [SKU] n/a
  • Energy Storage Module (ESM)
n/a
n/a 7018499 [F] Energy Storage Module (ESM) (Qty #28) Kit [SKU] n/a
  • Energy Storage Module (ESM)
n/a
n/a 7047503 [F] 8-Port 6Gbps SAS-2 RAID PCI Express HBA, B4 ASIC 375-3701 [F] 
n/a 7050794 [F] 6Gbps SAS-2 RAID PCI Battery Module, BBU08 371-4982 [F] 
n/a 7051731 [F] Energy Storage Module (ESM) (Qty #4) Kit [SKU] n/a
  • Energy Storage Module (ESM) [SKU]
n/a
n/a 7051732 [F] Energy Storage Module (ESM) (Qty #12) Kit [SKU] n/a
  • Energy Storage Module (ESM) [SKU]
n/a
n/a 7051733 [F] Energy Storage Module (ESM) (Qty #28) Kit [SKU] n/a
  • Energy Storage Module (ESM) [SKU]
n/a
35 6Gigabit SAS RAID PCI Express HBA PN#375-3644 is supported in PCIe slot 0 only in both the Sun Fire X4170 and Sun Fire X4275 as part of the Oracle Exadata V2.
36 6Gigabit SAS RAID PCI Express HBA PN#375-3644 is supported in PCIe slot 0 only in both the Sun Fire X4170 and Sun Fire X4275 as part of the Oracle Exadata V2.
37 PCI Express Flash Board PN#511-1500 dash rolled to change from a 5A to 3A fuse at F700.
38 96GB PCI Express Flash Accelerator SAS HBA PN#541-3731 is supported only in a configuration of 4 cards installed in PCIe slots 1, 2, 4, and 5 in the Sun Fire X4275 as part of the Oracle Exadata V2.
39 The minimum OS image required to support F20 M2 is Exadata image patch update 11.2.2.3.2 or later.
40 6Gigabit SAS RAID PCI Express HBA PN#375-3644 is supported in PCIe slot 0 only in both the Sun Fire X4170 and Sun Fire X4275 as part of the Oracle Exadata V2.
NOTE: Energy Storage Module (ESM) Kits Quantity 4, 12, or 28, PN#7018497, PN#7018498 and PN#7018499 are used as a preventive maintenance kit only.
NOTE: Support of the BBU08 battery PN#371-4982 or as a replacement for BBU07 PN#371-4746 requires minimum _LSI HBA_ firmware package build 12.9.0-0037 available in Exadata image patch update 11.2.2.1.1 or later. Refer to MOS note 888828.1 for the latest image patch details.
NOTE: For any Aura 1.0 cards failures PN#511-1275 or PN#511-1500 only replace with the Aura 1.1 card PN#541-4416 until further notice.
NOTE: Use the following Reference Doc to identify which Flash card is Installed in an Exadata Storage cell and order the correct FRU. See REFERENCE article 1416397.1.
Switch/Hub
Option # Manufacturing
Part #
Description Previous
Part #
n/a 310-0307 [F] Cooling Fan for Cisco Catalyst 4948 Switch n/a
n/a 371-4778 [F] ASSY, KMM, w/Japanese Keyboard & Mouse Module n/a
n/a 371-4779 [F] Buy Avocent MPU4032DAC-001 32-Port KVM Switch n/a
n/a 371-4780 [F] Buy Avocent KMM Drawer w/ US Keyboard n/a
n/a 371-4781 [F] Avocent (DSRIQ-USB) DB15M to RJ45/USB KVM Adapter n/a
n/a 371-4784 [F] Cisco Catalyst 4948 Switch n/a
n/a 371-4785 [F] Power Supply for Cisco Catalyst 4948 n/a
n/a 541-4267 Data Center InfiniBand Switch 36 n/a
  • Type A237 760 Watt AC Input Power Supply
n/a
  • Type A247 760 Watt AC Input Power Supply
300-2143 43 44 [F]
  • 350-1312 [F] [S]
  • Rear-to-Front Airflow Fan Module
n/a
  • 350-1566 45
  • Rear-to-Front Airflow Fan Module
n/a
  • Sun Datacenter InfiniBand Switch 36 Subassembly
n/a
    • 350-1345
    • Fan Module Filler Panel, FT0 and FT4
n/a
    • 3V Lithium Coin Cell Battery
n/a
    • 511-1232
    • 36-Port QSFP Switch
n/a
      • 371-4596
      • Kontron nanoEXTexpress-SP Module
n/a
    • 511-1312
    • Fan Board
n/a
    • 530-4319
    • Internal Power Cable
n/a
    • 530-4320
    • Internal Signal Cable
n/a
n/a 602-4758 Data Center InfiniBand Switch 36 n/a
  • Type A237 760 Watt AC Input Power Supply
n/a
  • Type A247 760 Watt AC Input Power Supply
300-2143 49 50 [F]
  • Type A247A 760 Watt AC Input Power Supply
300-2233 [F] 
  • 350-1312 [F] [S]
  • Rear-to-Front Airflow Fan Module
n/a
  • 350-1566 53
  • Rear-to-Front Airflow Fan Module
n/a
  • Sun Datacenter InfiniBand Switch 36 Subassembly
n/a
    • 350-1345
    • Fan Module Filler Panel, FT0 and FT4
n/a
    • 3V Lithium Coin Cell Battery
n/a
    • 511-1232
    • 36-Port QSFP Switch
n/a
      • 371-4596
      • Kontron nanoEXTexpress-SP Module
n/a
    • 511-1312
    • Fan Board
n/a
    • 530-4319
    • Internal Power Cable
n/a
    • 530-4320
    • Internal Signal Cable
n/a
n/a F541-3495 [F] Sun Datacenter InfiniBand Switch 36 [SKU] n/a
  • Sun Datacenter InfiniBand Switch 36 Subassembly
n/a
    • 350-1345
    • Fan Module Filler Panel, FT0 and FT4
n/a
    • 3V Lithium Coin Cell Battery
n/a
    • 511-1232
    • 36-Port QSFP Switch
n/a
      • 371-4596
      • Kontron nanoEXTexpress-SP Module
n/a
    • 511-1312
    • Fan Board
n/a
    • 530-4319
    • Internal Power Cable
n/a
    • 530-4320
    • Internal Signal Cable
n/a
41 760 Watt Power Supply PN#s 300-2233/300-2143 are used in the Sun Fire X4170 as part of the Oracle Exadata V2.
42 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
43 760 Watt Power Supply PN#s 300-2233/300-2143 are used in the Sun Fire X4170 as part of the Oracle Exadata V2.
44 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
45 Fan 350-1566 is not a FRU (use 350-1312 or 7061031).
46 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
47 760 Watt Power Supply PN#s 300-2233/300-2143 are used in the Sun Fire X4170 as part of the Oracle Exadata V2.
48 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
49 760 Watt Power Supply PN#s 300-2233/300-2143 are used in the Sun Fire X4170 as part of the Oracle Exadata V2.
50 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
51 760 Watt Power Supply PN#s 300-2233/300-2143 are used in the Sun Fire X4170 as part of the Oracle Exadata V2.
52 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
53 Fan 350-1566 is not a FRU (use 350-1312 or 7061031).
54 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
55 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2542 [F] System Board Assembly n/a
  • System Board
n/a
    • 3V Lithium Coin Cell Battery
n/a
  • 541-2543
  • System Board Tray
n/a

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
NS 371-2484 PDB Signal Cable
NS 511-1281 Connector Board (Paddle Card), SATA DVD
NS 530-3892 56 [F] 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm
NS 530-3927 [F] PDB to System Board Ribbon Cable
NS 530-4228 [F] SFF8087 to SFF8087 Mini-SAS Cable, 690mm
NS 541-2075 [F] Bus Bar Set
NS
  • 341-3096
  • Long Red Bus Bar
NS
  • 341-3104
  • Short Blue Bus Bar
NS 541-2636 57 [F] Lightpipe Assembly
NS
  • 330-4421
  • Right Side Endcap Lightpipe
NS
  • 541-2126
  • Left Side Endcap Lightpipe Assembly
NS
    • 330-4419
    • Lightpipe Button
NS
    • 330-4420
    • Lightpipe Holder
NS
    • 330-4424
    • Power Button
NS 541-3385 58 [F] Connector Board Assembly
NS
  • 341-5081
  • Mounting Bracket
NS
  • 511-1229
  • Connector Board
NS
  • 530-3510
  • Interlock Switch Cable
NS 541-3387 59 [F] SAS Expander Card Assembly
NS
  • 330-4945
  • Bracket
NS
  • 511-1214
  • SAS Expander Board
NS 541-3388 60 [F] Left Indicator Assembly
NS
  • 341-5084
  • Left Bracket
NS
  • 511-1251
  • Left LED Board
NS
  • 530-4244
  • Indicator Cable
NS 541-3389 61 [F] Right Indicator Assembly
NS
  • 341-5085
  • Right Bracket
NS
  • 511-1252
  • Right LED Board
NS
  • 530-4244
  • Indicator Cable
NS 541-3512 62 [F] Connector Board Assembly, SATA DVD
NS
  • 341-3168
  • Bracket
NS
  • 530-3510
  • Interlock Switch Cable
56 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm PN#530-3892 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
57 Lightpipe Assembly PN#541-2636 is used in the Sun Fire X4170 as part of the Oracle Exadata V2.
58 Connector Board Assembly PN#541-3385 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
59 SAS Expander Card Assembly PN#541-3387 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
60 Left Indicator Assembly PN#541-3388 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
61 Right Indicator Assembly PN#541-3389 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
62 Connector Board Assembly PN#541-3512 PN#541-3512 is used in the Sun Fire X4275 as part of the Oracle Exadata V2.
  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.