Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun SPARC Enterprise M3000 Server : Problem Documents


Problem Document Synopsis Last Modified Date
2329333.1 Sun SPARC Enterprise Mx000 Server: How to Troubleshoot XSCFU WDT event SCF-8005-NE due to Error "Recovery of wbuf failed due to a second write error" 2017-11-20
2235315.1 Solaris Panic BAD TRAP - occurred in module "qlc" due to a NULL pointer dereference 2018-03-07
2192795.1 SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: upon XSCF reboot, sckmd pppd and scfd daemons may generate messages on Solaris domain that can be interpreted as faults 2017-09-29
2149494.1 Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: "Fast Data Access MMU Miss" error along with BERR/BTO event during boot may be due to root file-system inconsistencies 2017-09-29
2121677.1 SPARC Enterprise M3000/M4000/M5000/M8000/M9000 How to Handle XSCFU WARNING: audit trail is 99% full 2017-09-06
2112004.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: XSCF SNMP Can take up to 1 hour to report a PSU AC input failure 2017-10-03
2027630.1 Hard Disk Not Seen In format After Physical Replacement 2018-03-05
2015360.1 Solaris Server Cannot Boot From SAN Disk, FC HBA Fibre Channel Link down 2018-03-07
1994858.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: XSCF's hostname set to "localhost" may cause XSCF unplanned reboots and domain(s) outage 2017-09-29
1993928.1 M4000 Domain Panics Reporting Fatal Error Has Occured in: PCIe fabric.(0x1)(0x45) and subsequent reboots Fails with Same Panic 2018-05-24
1993872.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: XSCF Reports Bad Data CRC Error at Console After Power Cycle and Loops uboot 2017-04-27
1982428.1 Sun SPARC Enterprise[TM] M3000/M4000/M5000/M8000/M9000: XSCF marked degraded with FMA code SCF-8006-WP, error reading inode #3082 2018-05-08
1981543.1 Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Server: A Slower Hard Disk was Sent as a Replacement 2017-10-05
1955763.1 Sun SPARC[R] Enterprise M3000/M4000/M5000/M8000/M9000 (OPL): XCP flashupdate command fails with error "This XSCF flash memory bank was switched by the XSCF board due to a previously encountered error condition" 2017-11-16
1945858.1 Failed to save core dump due to "panic: entering debugger (continue to save dump)" 2018-03-01
1942533.1 M-Series Servers: XSCF watchdog timeout without auto negotiation on Ethernet port 2018-05-17
1941503.1 Sparc Enterprise M3000/M4000/M5000/M8000/M9000 Servers: XSCF may be affected by security scanner tools running on the network generating SCF-800x-xx events 2017-04-05
1665705.1 Sun SPARC(R)Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Server: Ethernet LAN cable inserted into XSCF Serial Port may cause XSCF panic 2017-11-16
1625567.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: HW RAID Considerations and Issues 2017-05-16
1620578.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: XSCF displays memory error detected during boot 2017-10-19
1617956.1 I/O SERD threshold values are set too low and may result in PCIEX-8000-J5, PCIEX-8000-YJ and PCIEX-8000-KP faults. 2017-08-22
1607609.1 Sun SPARC Enterprise(R) M3000/M4000 - reset-all is canceled due to no available SCF path 2018-03-05
1599463.1 Amber light on the Mx000 Server lit without an error 2018-03-05
1591230.1 Diagnosing iostat Hard Errors on SPARC Servers DVD ROM 2018-02-15
1546140.1 Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 - Cannot Change Password for a user on XSCF and 'password: Operation failed' is displayed 2018-03-01
1531624.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 Server domain aborts auto-boot even though OBP variable auto-boot? is set to true. 2017-04-27
1509059.1 Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 Identifying HDDx of internal disks under mpxio control and removing internal disks from mpxio control 2018-04-05
1507710.1 Failed SSH login attempts on SPARC Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers domain(s) coming from XSCF(s) 2017-09-29
1484331.1 M3000 issues "strplumb: unable to get device info" after boot net 2018-05-09
1484297.1 bge related "spurious interrupt from ino" messages on M5000 2018-05-09
1465634.1 M3000/M4000/M5000 - OBP probe-all command execution and subsequent boot causes "Last Trap: Data Access Error" and MBU_A or IOU is degraded 2017-10-11
1451275.1 Sun SPARC[R] Enterprise M3000/M4000/M5000/M8000/M9000 Servers (OPL): Why FMA Events remain in the FMA history of M-Series XSCFUs 2017-11-16
1446655.1 Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 / DSCP : ipsec_check_inbound_policy: Policy Failure for the incoming packet (not secure); 2016-07-01
1393137.1 Sun SPARC(R) Enterprise m3000/m4000/m5000/m8000/m9000 (OPL) domain not responding to sendbreak due to Secure Mode on, Have it Off to be Able to Force a Kernel Crash Dump 2017-05-23
1381431.1 Oracle VTS may generate "Return value is -1" errors when run on M3000/M4000/M5000/M8000/M9000 platform where SPARC64 VII+ cpus are installed 2017-09-29
1361607.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Panel EEPROM and XSCF FMEM mismatched 2018-02-28
1353452.1 Sun SPARC Enterprise M3000/M4000/M5000: After UPS failure reports domain shuts down and does not power on 2017-04-27
1330510.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 Server: XSCF Email Reporting does not cover power and temperature events 2018-03-01
1328713.1 Sun SPARC[TM] Enterprise M3000, M4000, M5000, M8000, M9000 : CMU Upgrade Fails with SCF-8002-LX and SCF-8002-K2 MSG-IDs 2017-01-30
1317231.1 Sun SPARC[TM] Enterprise M3000: Incorrect Software Setting Prior to Shipping Certain M3000 Servers May Cause Unexpected Behavior. 2013-05-01
1300019.1 Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Server: delayed delivery of FMA mail messages from the XSCF 2015-12-22
1020429.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Domain hang-up detected (POST); FMA event SCF-8005-RA 2018-03-01
1019405.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: SAS WWID becoming unprogrammed 2017-10-30