![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1317231.1 : Sun SPARC[TM] Enterprise M3000: Incorrect Software Setting Prior to Shipping Certain M3000 Servers May Cause Unexpected Behavior.
Oracle Confidential PARTNER - Available to partners (SUN). Reason: internal info only Created from <SR 3-3282728501> Applies to:Sun SPARC Enterprise M3000 Server - Version Not Applicable and laterInformation in this document applies to any platform. SymptomsDue to incorrect software settings prior to shipping on certain Sun SPARC Enterprise M3000 servers the following issues will be seen:
CauseThis issue can occur on the following platforms:
PPMYYWWSSS PP is a factory code M is a model code YY is the last two digits of the year WW is the week of the calendar year SSS is a hexidecimal or alphanumeric sequence number.in the example above, serial number PX61113017 indicates it is from week 13 of 2011. SolutionThe resolution to this issue is to open a service request for an escalation mode password, and follow the procedures: For a configured XSCF use the procedures located at: https://support.us.oracle.com/oip/faces/secure/km/DocumentDisplay.jspx?id=1313741.1 For a new unconfigured xscf use procedures located at: https://support.us.oracle.com/oip/faces/secure/km/DocumentDisplay.jspx?id=1313793.1 References<NOTE:1313741.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000 - How to correct an invalid or wrong brandid setting on a configured XSCFU.<NOTE:1313793.1> - Sun SPARC[TM] Enterprise M3000, M4000, M5000 - How to correct an invalid or wrong brandid setting on a new xscfu. Attachments This solution has no attachment |
||||||||||||
|