Oracle Big Data Appliance X4-2 : Problem Documents


Problem Document Synopsis Last Modified Date
2227964.1 Reimage to BDA Base Image Fails with "PXE-MOF: Exiting Intel Boot Agent." 2017-01-28
2227955.1 CD-ROM Reimage to the BDA 4.5 Base Image Fails with "makebdaimage: Invalid BDADeploy json file : makebdaimage: deploy is not a valid v1 or v2 network config file" 2017-01-28
2227244.1 Removing a Virtual Drive for a Non-OS Drive with "MegaCli64 CfgLdDel Ln a0" Raises "Virtual Disk n is an OS drive - cannot be deleted without force option." 2017-01-26
2227128.1 After HDFS Disk Replacement with Multiple Disk Failures bdacheckhw Raises "Wrong slot mapping to HBA target" Errors for Slots After the Replaced Disk and "ERROR: Wrong number of virtual disks : 13" 2017-01-27
2195652.1 "ib0: Found gid with mismach lids.(cache:x,from arp: y)" Messages Reported on BDA OL5 Clusters 2018-03-23
2190814.1 bdacheckib on BDA V4.3-V4.5 Raises "iblinkinfo: invalid option -- 'R'" 2016-11-04
2129720.1 After DIMM Replacement bdacheckhw Reports Insufficient Memory. 2017-08-05
2081723.1 ILOM sending occasional incorrect sensor readings via IPMI when being polled by hwmgmtd on BDA V4.2 2016-07-12
2050261.1 Running networksetup-one Fails on One Node in Cluster while Installing X4-2 Oracle Big Data Appliance 2015-09-01
2025628.1 BDA Nodes Inaccessible Via the Client Data Network Due to the EOIB Interface not Re-linking and Joing BONDETH0 after the IB Link is Down then Up 2017-04-04
1988445.1 ibqueryerrors Reports SymbolErrors on One or More of the IB switch or HCA port 2018-05-23
1988202.1 Engineered Systems May Show: ERROR: Wrong fan 0 status : nr 2017-01-18
1985677.1 Running bdacheckcluster/bdacheckhw Oracle Big Data Appliance Reports: "INFO: Errors reported on disk : 0 1" 2018-04-25
1982023.1 "mammoth-reconfig add asr" Fails with "Error 11807" on BDA V4.1 2015-12-18
1964779.1 Networksetup-one Misconfigures ETH0 Route on BDA V4.1.0 2017-09-07
1956738.1 Running asrexachk on BDA V3.*/V4.* Raises, "/opt/oracle/bda/install/state/mammoth-saved.params: No such file or directory" 2014-12-23
1956717.1 asrexachk Reports ASR Setup Failures and ASR Alerts Are Not Picked Up on BDA V4.0 2018-01-17
1956549.1 The BDA utility, bdacheckhw Reports a Memory Failure: "WARNING: Hardware errors reported by ILOM : fault.memory.intel.sb.dimm_ce" 2017-01-05
1935983.1 Node Constantly Booting into the Grub Menu After Reboot Step of Oracle BDA Mammoth V4.0.0 Upgrade 2017-12-08
1935546.1 The bdachecknet Script Fails during Oracle Big Data Appliance Installation with Usage Messages 2017-06-16
1935504.1 Error when Running bdacheckib on Oracle Big Data Appliance during Installation of "bdacheckibx: entry for switch bda-01sw-ib1 not found in iblinkinfo output" 2014-10-20
1923938.1 bdachecknet to Verify the BDA Network Configuration Fails with Reverse Lookup Errors 2017-11-02
1921433.1 Running the networksetup-two Script for a New Installation on Oracle Big Data Appliance (BDA) X3-2 Fails with "networksetup-two: ping (element# 2) failed" 2018-01-10
1917133.1 Getting errors on bdacheckib ???s and on networksetup-two that the client and admin networks are on the same subnet. 2018-01-23
1664640.1 Running networksetup-two script for new installation on Oracle Big Data Appliance (BDA) X4-2 fails with "gwp2js:no ports found for leaf1" 2014-04-24
1663348.1 Running "bdacheckib -s" Command to Verifiy Infiniband Topology on New Install of Oracle Big Data Appliance X4-2 Shows Many Links as DOWN 2014-10-03
1663316.1 Unable to run "bdacheckib BdaShip.json" while Verifying InfiniBand Topology in Oracle Big Data Appliance X4-2 Installation Steps 2014-08-27
1663302.1 On Oracle Big Data Appliance X4-2 Verifying the Boot Order and Getting "grep: /tmp/bios.xml: No such file or directory" 2016-05-26
1637939.1 networksetup-two Fails on a BDA X4-2 rack with "no vlan for port, create it Legal values for VLAN ID is NO or 0 to 4094" 2014-03-24
1620735.1 Symbol Errors Increasing On Infiniband Switch 2017-11-09
1601685.1 Mammoth Install V2.3.1 Step 1 Fails with Error pinging ASR on Oracle Big Data Appliance 2014-05-06
1601635.1 Installing ASR in Mammoth 2.3.1 Step 15 Fails or Using 'mammoth-reconfig add asr' Fails with "Asr::Setupasr/Package [sun-servicetag]/ensure) change from absent to latest failed" 2014-05-06
1599019.1 Oracle Big Data Appliance Mammoth 2.2.1/2.3.1 "./mammoth-reconfig add asr" fails with "Undefined subroutine &MammothSteps::SetupASR::strftime" 2014-05-06
1596984.1 Running bdacheckcluster on Oracle Big Data Appliance raises: failed to connect: Busy 2016-08-10
1595762.1 Oracle Big Data Appliance Mammoth Installation 2.2.1 fails at Step 14 with ERROR: Errors found verifying ASR setup requirements 2014-03-23
1542706.1 ILOM How to reset an alert found in the ILOM (steps) 2016-08-31
1384286.1 DISKALRT-02004 Data hard disk failure 2016-04-14