![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2227964.1 : Reimage to BDA Base Image Fails with "PXE-MOF: Exiting Intel Boot Agent."
In this Document
Created from <SR 3-14057197351> Applies to:Big Data Appliance X4-2 Hardware - Version All Versions and laterLinux x86-64 Symptoms
Loading initrd.img.....................................ready
Probing EDD (ed PXE-E61: Media test failure, check cable PXE-MOF: Exiting Intel Boot Agent.
CauseOne potential cause is a corrupt/bad USB drive. Open an SR with Oracle Support to determine the specific problem being faced. SolutionIn the case of a corrupt/bad USB drive see: Steps to Recover/Restore a Corrupt/Bad USB Drive When Detected During Reimage/Reboot of a BDA Server (Doc ID 2227965.1). Attachments This solution has no attachment |
||||||||||||||||||
|