In this Document
Symptoms
Cause
Solution


Applies to:

Big Data Appliance X4-2 Full Rack - Version All Versions and later
Big Data Appliance X3-2 Full Rack - Version All Versions and later
Big Data Appliance X3-2 Starter Rack - Version All Versions and later
Big Data Appliance X3-2 In-Rack Expansion - Version All Versions and later
Big Data Appliance X4-2 In-Rack Expansion - Version All Versions and later
Linux x86-64

Symptoms

When configuring the hardware and network for a newly shipped BDA with a V4.1 image it is found that after configuring the network the BDA servers are not accessible on the admin network (but they are via the ILOMs).

In a little more detail the following general network configuration steps are completed:

- uploading the network.json configuration file to all servers on the BDA (after generating with the 4.1 configuration utility)
- running networksetup-one which configures admin and private networks
- connecting the BDA to the customer's networks
- running networksetup-two which configured the client network

After these steps it is found that BDA servers are not accessible on the admin network (but they are on the ILOMs).

Cause

This problem is caused by a bug in networksetup-one (actually in the underlying tool bdanetworktool) which incorrectly configures admin network routing so that the file /etc/sysconfig/network-scripts/route-eth0 contains incorrect information. 

The internal bug for this is: Bug 20381332 - networksetup-one misconfigures eth0 route

Solution

A workaround may be to manually update this file with the correct info and restart the eth0 interface.