![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 1637939.1 : networksetup-two Fails on a BDA X4-2 rack with "no vlan for port, create it Legal values for VLAN ID is NO or 0 to 4094"
In this Document
Applies to:Big Data Appliance X4-2 Full Rack - Version All Versions and laterBig Data Appliance X4-2 In-Rack Expansion - Version All Versions and later Big Data Appliance X4-2 Starter Rack - Version All Versions and later Big Data Appliance X4-2 Hardware - Version All Versions and later Linux x86-64 SymptomsOn some X4-2 racks the second step of the BDA network configuration with networksetup-two may fail with the following message: networksetup-two: no vlan for port, create it
Legal values for VLAN ID is NO or 0 to 4094 networksetup-two: verify vlan for port 0A-ETH-1 on xxx-hostname 01 manually and rerun
Note: It appears that not all BDA X4-2 racks are affected. CauseNot determined at this time.
SolutionIf this error message is encountered then networksetup-two should be rerun with the following additional arguments: # networksetup-two -V NO