Solution Type  Problem Resolution Sure

Solution  2195652.1 :   "ib0: Found gid with mismach lids.(cache:x,from arp: y)" Messages Reported on BDA OL5 Clusters  


Related Items
  • Big Data Appliance X4-2 Hardware
  •  
  • Big Data Appliance X5-2 Hardware
  •  
  • Big Data Appliance Hardware
  •  
  • Big Data Appliance X3-2 Starter Rack
  •  
  • Big Data Appliance X6-2 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>BDA>Big Data Appliance>DB: BDA_EST
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-13395880161>

Applies to:

Big Data Appliance X3-2 Starter Rack - Version All Versions and later
Big Data Appliance X5-2 Hardware - Version All Versions and later
Big Data Appliance X4-2 Hardware - Version All Versions and later
Big Data Appliance Hardware - Version All Versions and later
Big Data Appliance X6-2 Hardware - Version All Versions and later
Linux x86-64

Symptoms

On an BDA OL5.11 cluster messages like below are seen in the console and in /var/log/messages

ib0: Found gid with mismach lids.(cache:66,from arp: 67)
ib0: Found gid with mismach lids.(cache:50,from arp: 51)
ib0: Found gid with mismach lids.(cache:72,from arp: 73)
ib0: Found gid with mismach lids.(cache:50,from arp: 51)
ib0: Found gid with mismach lids.(cache:66,from arp: 67)
ib0: Found gid with mismach lids.(cache:66,from arp: 67)
ib0: Found gid with mismach lids.(cache:72,from arp: 73)
ib0: Found gid with mismach lids.(cache:50,from arp: 51)
....

These started showing up after new hardware was introduced into the Infiniband fabric and after all of the IB switches were patched in order to have them on the same firmware. The SMS Priority and Master settings were also modified on the switches.

Cause

The messages indicate that there was a change in the IB fabric configuration and therefore the node needs to clean up path records in the cache.

The issue is investigated:
1. Bug 17166934: CONSOLE WARNING : IB1: FOUND GID WITH MISMACH LIDS on OL5 still open
2. Bug 22923855: FOUND GID WITH MISMACH LIDS IN VAR LOG MESSAGES OF DB SERVER

 

Solution

This is an informative (and possibly persistent) message which does not affect functionality or performance.  It can safely be ignored.

There is no work-around at the moment other than to ignore the messages.

 

 