![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2129720.1 : After DIMM Replacement bdacheckhw Reports Insufficient Memory.
In this Document
Created from <SR 3-12558237841> Applies to:Big Data Appliance X4-2 Hardware - Version All Versions and laterLinux x86-64 SymptomsAfter DIMM replacement bdacheckhw is reporting less RAM than is configured for the server. # bdacheckhw
... SUCCESS: Found BDA v3 server : SUN SERVER X4-2L SUCCESS: Correct processor info : Intel(R) Xeon(R) CPU E5-2650 v2 @ 2.60GHz SUCCESS: Correct number of types of CPU : 1 SUCCESS: Correct number of CPU cores : 32 ERROR: Insufficient GB of memory : 47 INFO: Minimum GB of memory : 63 ...
ChangesRecent replacement of a DIMM. CauseCause is undetermined. Solution1. Reboot the server. 2. If the reboot does not clear the issue file a ticket with Oracle Support.
Attachments This solution has no attachment |
||||||||||||||||||
|