Sun Microsystems, Inc.   Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Storage 7410 (SAS 2.0) - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
This product is based on the Sun Fire X4440 server and the Sun Disk Shelf 24x3.5" SAS-2, but uses specialized components. Only use parts listed in the Sun Storage 7410 (SAS 2.0) Full Components List to service this product.

Array Controller
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7045305 [C] 6Gbps SAS-2 Interface Module (SIM FW 3527) 7014946 [C] [S] 
n/a 7053644 [C] 6Gbps SAS-2 Interface Module (SIM FW 3529) 7045305 [C] 
n/a 542-0194 [C] [S] 6Gbps SAS-2 Interface Module (SIM FW 3520 or 3524) n/a
n/a 7014946 [C] [S] 6Gbps SAS-2 Interface Module (SIM FW 3524 or 3527) 542-0194 [C] [S]
NOTE: Don't mix SIM card firmware 3520 with SIM card firmware 3524. See FAB 1307357.1 for details.
NOTE: 6Gbps SAS-2 Interface Module (SIM) PN#542-0194, PN#7014947, PN#7045305 and PN#7053643 are used in the OPTIONAL Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Storage 7320.
Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-4277 [C] 3V Lithium coin battery n/a
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
n/a 310-0128 Opteron Heatsink n/a
n/a 371-4042 [F] 2.3 GHz CPU, Opteron 2356 Quad Core, B3 Stepping, 75W n/a
n/a 371-4044 [F] 2.3 GHz CPU, Opteron 8356 Quad Core, B3 Stepping, 75W n/a
n/a 371-4681 [F] 2.6 GHz CPU, Opteron 2435 6-Core, D0 Stepping, 75W n/a
n/a 371-4684 [F] 2.6 GHz CPU, Opteron 8435 6-Core, D0 Stepping; 75W n/a
n/a 540-7597 [F] CPU/Memory Mezzanine Assembly n/a
  • 330-4622
  • Air Duct
n/a
  • 501-7723
  • Mezzanine Card
n/a
  • 541-2769
  • Tray
n/a
n/a 540-7602 [F] HyperTransport Bridge Card & Risers for Quad Core CPU n/a
  • 270-7916 [F]
  • Hyper-Transport Bridge Risers (×2)
n/a
  • 501-7915
  • Hyper-Transport Bridge Card
n/a
n/a 540-7953 [F] CPU/Memory Mezzanine Assembly 540-7597 [F]
  • 330-4622
  • Air Duct
n/a
  • 511-1395
  • Mezzanine Card
n/a
  • 541-2769
  • Tray
n/a
n/a 541-2906 [C] HyperTransport Riser n/a
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 530-3771 [C] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 1m, Grey n/a
n/a 530-3886 [C] 4X Mini SAS Cable, SFF-8088 to SFF-8088, 0.5M n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
X4237A-N [S] 375-3606 [C] Sun Dual Port 40Gb/sec 4x Infiniband QDR Host Channel Adapter PCI Express n/a
X4242A [S] 7092767 [C] Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter 375-3696 [C]
n/a 371-3024 [C] Cluster Heartbeat Card n/a
n/a 375-3696 [C] Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter n/a
n/a 542-0298 [C] Cluster Heartbeat Assembly n/a
  • Cluster Heartbeat Card
n/a
  • 541-4350
  • EMI Gasket
n/a
n/a 7056175 [C] Cluster Heartbeat Assembly 542-0298 [C]
  • Cluster Heartbeat Card
n/a
  • 541-4350
  • EMI Gasket
n/a
n/a 7089470 [C] Cluster Heartbeat Assembly 7056175 [C] 
  • 541-4350
  • EMI Gasket
n/a
  • 7087050
  • Cluster Heartbeat Card
n/a
Disk Backplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 501-7730 [F] 8-Slot Disk Backplane, PATA DVD n/a
n/a 542-0355 [F] Backplane Retainer Clip Kit n/a
  • 330-5301
  • Grey 2U Backplane Retainer Clip
n/a
Disks
Option # Manufacturing
Part #
Description Previous
Part #
n/a 350-1574 Disk Shelf SSD Filler Panel n/a
n/a 540-7711 [C] 500GB - 5400 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HTE545050KTA300 [HTE5450SASSUN500G]
    (500GB - 5400 RPM - SATA Disk)
n/a
  • Marlin 2.5" Bracket
n/a
n/a 540-7793 2 [C] 100GB Solid State SATA Drive Assembly without Encryption (EAEU part - see note below) n/a
  • Stec M8ISB2-100UC [Inquiry Unknown] (100GB - 2.5" Solid State - SATA Disk) without Encryption (EAEU part - see note below)
n/a
  • Marlin 2.5" Bracket
n/a
n/a 541-4242 Disk Shelf HDD Filler Panel n/a
n/a 542-0184 [C] 500GB - 7200 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST9500530NS [ST95000NSSUN500G]
    (500GB - 7200 RPM - SATA Disk)
n/a
  • Marlin Bracket
n/a
n/a 542-0274 [C] 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST32000444SS [ST32000SSSUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Toshiba MK2001TRKB [MK2001RKBSUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 542-0340 [C] 1TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST31000424SS [ST31001SSSUN1.0T] (1TB - 7200 RPM - SAS Disk)
n/a
  • Toshiba MK1001TRKB [MK1001RKBSUN1.0T] (1TB - 7200 RPM - SAS Disk)
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7015704 4 [C] 18GB SAS Solid State Drive Assembly 542-0286 3 [S]
  • Stec Z16IZD3C-18UC [Inquiry Unknown] (18GB - 3.5" Solid State - SAS Disk)
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7042964 [C] 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HUS723020ALS640 [H7220AS60SUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7309527 [C] 18GB SAS Solid State Drive Assembly n/a
  • 18GB - 3.5" Solid State - SAS Disk
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7350582 [C] 200GB SAS-3 Solid State Drive Assembly with 1 bracket and 1 of the following disks: n/a
  • HGST HUSMH4020ASS210 [HBCAC2DH6SUN200G] (200GB - 2.5" Solid State SAS Disk)
n/a
  • 2.5" Adapter
n/a
  • Left Bracket
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7309938 5 [C] [A] 200GB SAS-3 Solid State Drive Assembly with 1 bracket and 1 of the following disks: n/a
  • HGST HUSMM1640ASS200 [HSCAC2DA6SUN200G] (200GB - 2.5" Solid State - SAS Disk)
n/a
  • 2.5" Adapter
n/a
  • Left Bracket
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7320823 6 [C] [A] 100GB Solid State SATA Drive Assembly n/a
  • Samsung MS4SC2JH2ORA480G [MS4SC2JH2ORA100G] (100GB - 2.5" Solid State - SATA Disk)
n/a
  • Marlin 2.5" Bracket
n/a
n/a 7352445 [C] [A] 200GB SAS-3 Solid State Drive Assembly without Encryption (EAEU part - see note below) n/a
  • HGST HUSMH4020ASS214 [HBSAC2DH6SUN200G] (200GB - 2.5" Solid State SAS3 Disk without Encryption) (EAEU part - see note below)
n/a
  • 2.5" Adapter
n/a
  • Left Bracket
n/a
  • Stingray 3.5" Mounting Bracket
n/a
2 See REFERENCE article 2136638.1 for support strategy information for replacing 100GB Readzilla disks.
3 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1 for details.
4 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1 for details.
5 See How To article 1984011.1 for information on replacing ZFS Logzilla with a higher capacity SSD.
6 See REFERENCE article 2136638.1 for support strategy information for replacing 100GB Readzilla disks.
NOTE: Disk Drive Assembly PN#542-0274 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
NOTE: PN#350-1574 and PN#541-4242 are used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
NOTE: Disk Drive Assembly PN#542-0340 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
NOTE: Disk Drive Assembly PN#7015704 / PN#542-0286 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
X1027A-Z-N [S] 7054890 [C] PCI Express Dual 10-Gigabit Ethernet Fiber 501-7283 [C]
X4446A-Z-N [S] 7054739 [C] PCI Express Quad Gigabit Ethernet UTP 375-3481 [C]
X5558A [S] 7058828 [C] 10Gb/sec XFP Optical Transceiver Multi Mode Short Range (SR) 375-3301 [C]
X5560A-Z-N [S] 375-3495 [C] 10Gb/Sec XFP Optical Transceiver Single Mode Long Range (LR) n/a
X7280A-2-N [S] 371-0905 [C] PCI Express Dual Gigabit Ethernet UTP n/a
X7281A-2-N [S] 7056733 [C] PCI Express Dual Gigabit Ethernet MMF 371-0904 [C]
n/a 371-0904 [C] PCI Express Dual Gigabit Ethernet MMF n/a
n/a 375-3301 [C] 10Gb/sec XFP Optical Transceiver Multi Mode Short Range (SR) n/a
n/a 375-3481 [C] PCI Express Quad Gigabit Ethernet UTP n/a
n/a 501-7283 [C] PCI Express Dual 10-Gigabit Ethernet Fiber n/a
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2211 [F] Fan Power Board n/a
  • 330-4463
  • Top Bracket
n/a
  • 330-4464
  • Bottom Bracket
n/a
  • 501-7695
  • Fan Board
n/a
n/a 541-2940 [C] CPU Dual Fan Assembly w/ Metal Fingerguards n/a
  • 310-0119
  • Delta Fan, 60×38mm, 2U
n/a
Fibre Channel
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCIE2FC-QF4-N [S] 375-3356 [C] 4Gigabit/Sec PCI Express Dual FC Host Adapter n/a
SG-XPCIE2FC-QF8-Z [S] 371-4325 [C] 8Gigabit/Sec PCI Express Dual FC Host Adapter n/a
I/O
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2109 [C] x8/x8 XAUI Riser Card Assembly n/a
  • 341-4139
  • PCI Filler Panel
n/a
  • 501-7719
  • x8/x8 XAUI Riser Card
n/a
  • 541-2736
  • Riser Bracket
n/a
n/a 541-2299 [C] x16/x4 Riser n/a
Memory
Option # Manufacturing
Part #
Description Previous
Part #
n/a F540-7599 [C] 4GB (2 × 2GB) Memory [SKU] n/a
  • 2GB Registered ECC DDR2-667 DIMM
n/a
n/a F540-7600 [C] 8GB (2 × 4GB) Memory [SKU] n/a
  • 4GB Registered ECC DDR2-667 DIMM
n/a
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-1897 [C] Type A217 1050 Watt AC Input Power Supply n/a
n/a 300-2235 [C] Type A249 1100/1200 Watt AC Input Power Supply n/a
n/a 300-2318 [C] 764W AC Input Power/Cooling Module 300-2276 [C]
n/a 541-2073 [F] Power Distribution Board/Bus Bar Assembly n/a
  • 341-3166
  • Bus Bar Left
n/a
  • 341-3167
  • Bus Bar Right
n/a
  • Horizontal Power Distribution Board
n/a
  • Vertical Power Distribution Board
n/a
NOTE: 764W AC Input Power Supply and Fan Assembly PN#300-2276 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
Rack
Option # Manufacturing
Part #
Description Previous
Part #
DS2X-4URK-19U [S] 350-1531 Rackmount Kit n/a
  • n/a
  • Right Mounting Rail
n/a
  • n/a
  • Left Mounting Rail
n/a
n/a 371-2740 [C] 1U/2U Snap-In Slide Rail Rackmount Kit, 730mm n/a
n/a 371-2741 [C] 1U/2U Screw-Mount Slide Rail Rackmount Kit, 730mm n/a
n/a 371-2742 [C] 1U/2U Cable Management Arm n/a
NOTE: Rackmount Kit DS2X-4URK-19U/350-1531 is used for rack mounting the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
Removable Media
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2732 [C] USB Assembly n/a
  • 330-4418
  • DVD Tray
n/a
  • 341-4072
  • DVD Filler Panel
n/a
  • 501-7698
  • USB Board
n/a
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCIESAS-GEN2-Z [S] 7056272 [C] 8-Port 6Gbps SAS-2 External RAID HBA 375-3609 [C]
n/a 375-3609 [C] 8-Port 6Gbps SAS-2 RAID HBA n/a
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 540-7952 7 [F] Motherboard n/a
  • 3V Lithium coin battery
n/a
7 While the system board is a FRU, Contact Oracle Support if this part is suspected to be faulty.

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[A] = Alternate, can be used in system; wasn't used during production
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
NS 530-3927 [F] PDB to System Board Ribbon Cable
NS 540-7980 [F] Disk Shelf Chassis Assembly
NS
  • 330-5203
  • Front Left End Cap
NS
  • 330-5204
  • Front Right End Cap
NS
  • 375-3659
  • Centerplane Assembly
NS 541-2213 [F] Connector Board Assembly, PATA DVD
NS
  • 341-3097
  • Bracket
NS
  • 501-7720
  • Connector Board (Paddle Card), PATA DVD
NS
  • 530-3510
  • Interlock Switch Cable
NS 7041264 [F] Disk Shelf Chassis Assembly
NS
  • 330-5203
  • Front Left End Cap
NS
  • 330-5204
  • Front Right End Cap
NS
  • 7041262
  • Centerplane Assembly
NS F540-7610 [F] SAS/SATA Cable Kit [SKU]
NS
  • 530-3892
  • 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm
NS
  • 530-3894
  • 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 560mm
NS
  • 530-3895
  • 4x Mini SAS Cable, SFF-8087 to SFF-8087, 530mm
NOTE: PN#540-7980 and 7041264 are used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun Storage 7410 (SAS 2.0).
  Copyright © 2018 Oracle and/or its affiliates.  All rights reserved.
 Feedback