Problem Document
|
Synopsis
|
Last Modified Date
|
2397110.1 |
IP Address of the Infiniband Switch changes during firmware upgrade |
2018-05-14
|
2392066.1 |
How can an Infiniband interface show in listlinkup as "up (Disabled)" Example: Connector 12A Present <-> Switch Port 11 is up (Disabled) |
2018-04-27
|
2368350.1 |
ntpd: unrecognized service |
2018-03-05
|
2362646.1 |
Logging in as ilom-admin on a 36P or GW Infiniband Switch running Firmware 2.2.8-2 hangs as well as the spsh command hangs |
2018-03-15
|
2362194.1 |
getmaster returns "Local SM enabled and running, state MASTER NOT UP" |
2018-02-26
|
2359268.1 |
Logging in as ilom-admin on a 36P or GW Infiniband Switch hangs as well as the spsh command hangs when logged in as root |
2018-02-09
|
2353380.1 |
root filesystem of Infiniband Switch reached to 94% |
2018-03-12
|
2344681.1 |
Infiniband Switch ib02 Subnet Manager Stuck In DISCOVER State |
2018-01-18
|
2341655.1 |
IB switch ILOM timezone setting does not match the OS symlink /conf/localtime |
2018-01-08
|
2302714.1 |
Preventing an Infiniband Switch from becoming un-bootable (during upgrade for Sun Datacenter Infiniband 36 or during reboot or upgrade for Sun Network QDR InfiniBand Gateway Switch) due to Real Time Clock corruption |
2018-01-10
|
2280595.1 |
During upgrading or re-booting of an Infiniband switch from version 2.1.x the switch will not boot, NO Link Lights, Fans spinning full speed |
2017-09-12
|
2227109.1 |
Exalogic VM lost network communication through both vnics when one IB gateway switch was rebooted |
2018-01-03
|
2226978.1 |
NM2-GW Upgrade Failing From 2.1.6-2 To 2.2.2.7 |
2017-02-01
|
2187802.1 |
Infiniband Switch - Firmware Downgrade To 2.1.6 Fails With Error: Cannot proceed with downgrade on this SP. |
2017-01-08
|
2171362.1 |
CVE-1999-0517 An SNMP community name is the default (e.g. public), null, or missing on an Infiniband Switch |
2018-05-09
|
2146310.1 |
High CPU utilization on NM2 InfiniBand Switches |
2018-03-19
|
2113843.1 |
Infiniband Switch - Exachk alert for "Life expectancy" - false alerts in Exachk version 12.1.0.2.6 |
2018-04-04
|
2084598.1 |
smpartition start - Fails With Unable To Get Rpc Version On Some Nodes In The Fabric |
2018-01-03
|
2057561.1 |
lumain: (ht_session_create): authentication error, invalid credentials |
2017-07-11
|
2020560.1 |
Running fwverify on Infiniband Switch returns FAILED against installed /etc/rc.d/* startup scripts. |
2018-04-13
|
2009033.1 |
Infiniband Switch showunhealthy Message "Flash disk has bad blocks" |
2018-03-22
|
1988452.1 |
dladm show-part shows link down over an IB partition |
2018-01-03
|
1963309.1 |
Master Subnet Manager is not same across all switches |
2018-03-19
|
1921832.1 |
smpartition add outputs "Wrong value for pkey. Legal value is 1 to 0x7fff" |
2016-05-26
|
1921766.1 |
showvnic command run on an IB gateway switch outputs "WAIT-VHUB" |
2017-09-11
|
1643478.1 |
The ILOM/BUI interface of the IB GW switches do not appear to be behaving correctly on firmware 2.0.8-1 |
2017-07-11
|
1641577.1 |
ibcheckerrors reporting #warn: counter SymbolErrors = 65535 (threshold 10) lid 62 port 255 |
2016-10-18
|
1614149.1 |
"fwverify" Command Failure On IB Switches |
2015-06-16
|
1605955.1 |
How to enable an Infiniband SUN DCS 36p switch port when it 's auto-disabled |
2017-09-29
|
1576848.1 |
New fan installed in Infiniband gateway switch runs faster |
2013-08-16
|
1572353.1 |
showunhealthy reports Error on I2C |
2015-11-17
|
1501042.1 |
NM2-GW listlinkup output shows Bridge-0 Port 0A-ETH-1 (Bridge-0-2) down (Enabled) on a port that was previously working |
2018-03-12
|
1406959.1 |
Sun ZFS Storage Appliance: OpenSM messages continually sent to Subnet Manager in Exadata environment |
2012-04-10
|