Solution Type  Problem Resolution Sure

Solution  1643478.1 :   The ILOM/BUI interface of the IB GW switches do not appear to be behaving correctly on firmware 2.0.8-1  


Related Items
  • Sun Datacenter InfiniBand Switch 36
  •  
  • Oracle Exalogic Elastic Cloud X2-2 Hardware
  •  
  • Sun Network QDR InfiniBand Gateway Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-8663665986>

Applies to:

Sun Network QDR InfiniBand Gateway Switch - Version All Versions to All Versions [Release All Releases]
Sun Datacenter InfiniBand Switch 36 - Version All Versions to All Versions [Release All Releases]
Oracle Exalogic Elastic Cloud X2-2 Hardware - Version All Versions to All Versions [Release All Releases]
Embedded Linux x86

Symptoms

When attempting to access IB ilom via web browser Chrome and Firefox, the pages are only half rendered with the message "View the version of currently installed platform firmware".

display_version


But the page can show correctly by IE 10.

version correct

 

And When starting fabric manager, none of the information is populated on any of web browser, including on IE, Chrome and Firefox. The stats remain as 'Loading...'.

loading


Cause

  BUI/ILOM is not compatible with mozilla firefox version 6.0

Solution

This issue has been fixed by the firmware 2.1.4 and later version

References

<BUG:15747583> - SUNBT7099717 BUI/ILOM NOT COMPATIBLE WITH MOZILLA FIREFOX VERSION 6.0