Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2057561.1
Update Date:2017-07-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2057561.1 :   lumain: (ht_session_create): authentication error, invalid credentials  


Related Items
  • Sun Datacenter InfiniBand Switch 36
  •  
  • Sun Network QDR InfiniBand Gateway Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-11399179531>

Applies to:

Sun Network QDR InfiniBand Gateway Switch - Version All Versions and later
Sun Datacenter InfiniBand Switch 36 - Version All Versions and later
Information in this document applies to any platform.

Symptoms

When attempting to login to a switch GUI with a valid user and no password or bad password, the following error message is written to the /var/log/messages file:

lumain: (ht_session_create): authentication error, invalid credentials


Cause

Every attempt of login to a switch GUI with a valid user and no password or bad password will cause that message to be generated.

This can be verified by checking event list

23965  Fri Sep 18 08:09:06 2015  Audit     Log       minor   
       root : Open Session : object = /session/type : value = www : error


The timestamp matches the message, the user was root, the session type was www.

Solution

 Make sure that correct credentials are used during login.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback