Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1641577.1
Update Date:2016-10-18
Keywords:

Solution Type  Problem Resolution Sure

Solution  1641577.1 :   ibcheckerrors reporting #warn: counter SymbolErrors = 65535 (threshold 10) lid 62 port 255  


Related Items
  • Sun Datacenter InfiniBand Switch 36
  •  
  • Sun Network QDR InfiniBand Gateway Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-8762545311>

Applies to:

Sun Network QDR InfiniBand Gateway Switch - Version All Versions and later
Sun Datacenter InfiniBand Switch 36 - Version All Versions and later
Information in this document applies to any platform.
ibcheckerrors is reporting errors similar to the following even after running ibclearerrors & ibclearcounters

Symptoms

 ++ ibcheckerrors
#warn: counter SymbolErrors = 65535     (threshold 10) lid 62 port 255
#warn: counter LinkDowned = 255         (threshold 10) lid 62 port 255
Error check on lid 62 (SUN DCS 36P QDR exa-ib1.oracle.com) port all:  FAILED

Cause

 The ibcheckerrors command has been deprecated and should not be used.

Solution


The following command replaces ibcheckerrors:
ibdiagnet  -skip dup_guids


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback