Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2226978.1
Update Date:2017-02-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2226978.1 :   NM2-GW Upgrade Failing From 2.1.6-2 To 2.2.2.7  


Related Items
  • Sun Network QDR InfiniBand Gateway Switch
  •  
  • Exalogic Elastic Cloud X5-2 Quarter Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-14067981088>

Applies to:

Exalogic Elastic Cloud X5-2 Quarter Rack - Version X5 to X5 [Release X5]
Sun Network QDR InfiniBand Gateway Switch - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.

Symptoms

NM2-GW Upgrade failing from 2.1.6-2 to 2.2.2.7

-> load -source sftp://temp:oracle123@10.x.x.x/tmp/sundcs_gw_repository_upgrade_2.1_to_2.2.2_7.pkg
Downloading firmware image. This will take a few minutes.

Error: Exiting Firmware update. Please see file /tmp/fw_upgrade_pre_check.err for details.

Firmware image update failed.

load: Command Failed

Cause

The upgrade process needs to run twice to finish it. The first check will be a pre-run and second one updates the firmware.

Solution

The product notes provide known problems regarding the IB switch firmware upgrade. These notes pertain to the 2.1.8-1 firmware for the gateway. The same checklist document is applicable to 2.2.2.7.

 http://docs.oracle.com/cd/E36256_01/pdf/E36258.pdf

The upgrade process to 2.2.2.7, needs to run twice to finish it. The first check will be a pre-run and second one updates the firmware.

 

[root@exalogicgw02 ~]# spsh

Oracle(R) Integrated Lights Out Manager

Version ILOM 3.0 r47111

Copyright (c) 2012, Oracle and/or its affiliates. All rights reserved.

-> load -source sftp://temp:oracle123@10.x.x.x/tmp/sundcs_gw_repository_upgrade_2.1_to_2.2.2_7.pkg
Downloading firmware image. This will take a few minutes.

Error: Exiting Firmware update. Please see file /tmp/fw_upgrade_pre_check.err for details.

Firmware image update failed.

load: Command Failed
->
> load -source sftp://temp:oracle123@10.x.x.x/tmp/sundcs_gw_repository_upgrade_2.1_to_2.2.2_7.pkg
Downloading firmware image. This will take a few minutes.

NOTE: Firmware upgrade will upgrade firmware on SUN DCS gw Kontron module,
I4 and BridgeX. Upgrade takes few minutes to complete.

ILOM will enter a special mode to load new firmware. No other tasks
should be performed in ILOM until the firmware upgrade is complete.

WARNING: Subnet manager is running on the switch. Proceeding with installation will stop it.
Are you sure you want to load the specified file (y/n)? y
Setting up environment for firmware upgrade. This will take a few minutes.
Starting SUN DCS gw FW update

==========================
Performing operation: I4 A
==========================
I4 A: I4 is already at the given version.

==========================
Performing operation: BX A
==========================
BX A: BX is already at the given version.

==========================
Performing operation: BX B
==========================
BX B: BX is already at the given version.

===========================
Summary of Firmware update
===========================
I4 status : FW UPDATE - SUCCESS
I4 update succeeded on : none
I4 already up-to-date on : A
I4 update failed on : none
BX status : FW UPDATE - SUCCESS
BX update succeeded on : none
BX already up-to-date on : A, B
BX update failed on : none

=========================================
Performing operation: SUN DCS gw firmware update
=========================================
SUN DCS gw Kontron module fw upgrade from 2.1.6-2 to 2.2.2-7:
Upgrade started...
Please reboot the system to enable firmware update of Kontron module. The download of the Kontron firmware image happens during reboot.

After system reboot, Kontron FW update progress can be monitored in browser using URL [http://system] OR at OS command line prompt by using command [telnet system 1234] where system is the hostname or IP address of SUN DCS 36P or GW.

Firmware update is complete.

->
[root@exalogiccn01 tmp]# ssh 10.255.194.32
FW upgrade completed successfully on Wed Jan 18 22:45:31 GMT 2017.
Please run the "fwverify" CLI command to verify the new image.
This message will be cleared on next reboot.

You are now logged in to the root shell.
It is recommended to use ILOM shell instead of root shell.
All usage should be restricted to documented commands and documented
config files.
To view the list of documented commands, use "help" at linux prompt.
[root@exalogicgw02 ~]# version
SUN DCS gw version: 2.2.2-7
Build time: Aug 26 2016 10:25:49
FPGA version: 0x34
SP board info:
Manufacturing Date: 2015.05.12
Serial Number: "NCDKO0335"
Hardware Revision: 0x0200
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010
[root@exalogicgw02 ~]#
[root@exalogicgw02 ~]# smpartition list active
# Sun DCS IB partition config file
# This file is generated, do not edit
#! version_number : 105
Default=0x7fff, ipoib :
ALL_CAS=both,
ALL_SWITCHES=full,
SELF=full;
SUN_DCS=0x0001, ipoib :
ALL_SWITCHES=full;
= 0x0002,ipoib:
0x0010e00001877a4a=full,
0x0010e00001877a49=full,
0x0010e0000187a61a=full,
0x0010e0000187a619=full,
0x0010e0000178edc2=both,
0x0010e0000178edc1=both,
0x0010e0000174a872=both,
0x0010e0000174a871=both,
0x0010e00001771902=both,
0x0010e00001771901=both,
^CMore--
[root@exalogicgw02 ~]# ^C
[root@exalogicgw02 ~]# showvnics
ID STATE FLG IOA_GUID NODE IID MAC VLN PKEY GW
--- -------- --- ----------------------- -------------------------------- ---- ----------------- --- ------ --------
0 UP N E98C3328E43CC207 exalogiccn01 EL-C 192.168.10.11 0000 00:21:F6:45:09:98 3403 0x8007 0A-ETH-1
39 WAIT-IOA N 66146B459CD5060B exalogiccn08 EL-C 192.168.10.18 0000 00:14:4F:FA:8F:08 3404 0x8008 0A-ETH-1
56 UP N FC13DD25543A3516 exalogiccn04 EL-C 192.168.10.14 0000 00:14:4F:F9:85:9E 3405 0x800a 0A-ETH-1
7 WAIT-IOA N D37D8F9FC0248516 0000 00:14:4F:FA:65:CB 3405 0x800a 0A-ETH-1
10 UP N 3B27D890DFE98E24 exalogiccn06 EL-C 192.168.10.16 0000 00:14:4F:FB:0F:9D 3405 0x800a 0A-ETH-1
25 WAIT-IOA N DE92824FE270262D exalogiccn05 EL-C 192.168.10.15 0000 00:14:4F:FB:FE:EA 3408 0x800d 0A-ETH-1
43 UP N E516F42D78D69132 exalogiccn08 EL-C 192.168.10.18 0000 00:14:4F:F9:EB:44 3404 0x8008 0A-ETH-1
52 UP N 764C6093930AF349 exalogiccn01 EL-C 192.168.10.11 0000 00:14:4F:F9:19:4D 3405 0x800a 0A-ETH-1
37 WAIT-IOA N E69F01037BFAE557 0000 00:14:4F:FB:FE:CD 3408 0x800d 0A-ETH-1
2 WAIT-IOA N 16D34EFE266D107D 0000 00:14:4F:F9:BC:39 3404 0x8008 0A-ETH-1
17 WAIT-IOA N 38DEBD0FE572747E 0000 00:14:4F:F9:05:F2 3405 0x800a 0A-ETH-1
33 WAIT-IOA N 0CBDB4ABE8B4A795 0000 00:14:4F:F9:EC:B9 3408 0x800d 0A-ETH-1
47 UP N F57C534544348E9D exalogiccn01 EL-C 192.168.10.11 0000 00:14:4F:FB:83:85 3405 0x800a 0A-ETH-1
29 WAIT-IOA N 17F04E7F414B529E exalogiccn03 EL-C 192.168.10.13 0000 00:14:4F:F9:1D:C5 3408 0x800d 0A-ETH-1
1 UP N 9659B0BAA357AFA7 exalogiccn06 EL-C 192.168.10.16 0000 00:14:4F:F8:24:7E 3404 0x8008 0A-ETH-1
41 UP N CA1A9346446EADF2 exalogiccn01 EL-C 192.168.10.11 0000 00:14:4F:F9:53:7C 3404 0x8008 0A-ETH-1
21 WAIT-IOA N 7512F40AAC5D0DF5 0000 00:14:4F:FB:D5:94 3408 0x800d 0A-ETH-1
51 UP N 7EE4B56E5FB553F8 exalogiccn07 EL-C 192.168.10.17 0000 00:14:4F:FB:00:5F 3405 0x800a 0A-ETH-1
44 WAIT-IOA N 9FFD44B82FD90D23 0000 00:14:4F:F8:8B:81 3405 0x800a 0A-ETH-2
19 WAIT-IOA N F647C2DEC9020642 0000 00:14:4F:F9:26:9E 3405 0x800a 0A-ETH-2
4 WAIT-IOA N 237AECE5CD755643 0000 00:14:4F:FB:C5:89 3404 0x8008 0A-ETH-2
22 WAIT-IOA N 79826E46455B485E 0000 00:14:4F:F9:32:A6 3408 0x800d 0A-ETH-2
34 WAIT-IOA N 9D9909D20B7E8F6E 0000 00:14:4F:F9:E8:23 3408 0x800d 0A-ETH-2
57 UP N D9D4DF6542ACC96E exalogiccn06 EL-C 192.168.10.16 0000 00:14:4F:FA:6E:0E 3405 0x800a 0A-ETH-2
48 UP N 64087DE8BEF52089 exalogiccn08 EL-C 192.168.10.18 0000 00:14:4F:F8:0E:1F 3405 0x800a 0A-ETH-2
40 UP N C76AB9DE603F27B7 exalogiccn05 EL-C 192.168.10.15 0000 00:14:4F:F9:DB:63 3404 0x8008 0A-ETH-2
15 UP N D68B860E22D5BAC4 exalogiccn08 EL-C 192.168.10.18 0000 00:14:4F:F8:7B:BC 3403 0x8007 0A-ETH-2
30 WAIT-IOA N 927F3383F27877D8 0000 00:14:4F:F9:80:CD 3408 0x800d 0A-ETH-2
53 UP N 63FD27706DDB3FF2 exalogiccn05 EL-C 192.168.10.15 0000 00:14:4F:F9:EF:DD 3405 0x800a 0A-ETH-2
26 WAIT-IOA N CE707EBE98AC1CFB 0000 00:14:4F:F9:2F:D5 3408 0x800d 0A-ETH-2
35 WAIT-IOA N 5AAE2674E9924C25 0000 00:14:4F:FB:3A:A5 3408 0x800d 0A-ETH-3
3 WAIT-IOA N 8C3C2E404429AB56 0000 00:14:4F:FB:47:41 3404 0x8008 0A-ETH-3
23 WAIT-IOA N 83BFE47EE7DC356D exalogiccn04 EL-C 192.168.10.14 0000 00:14:4F:FA:EC:2E 3408 0x800d 0A-ETH-3
49 UP N 774169266FEEC0A6 exalogiccn07 EL-C 192.168.10.17 0000 00:14:4F:F8:66:F5 3404 0x8008 0A-ETH-3
54 UP N 2D09792D32EF3AA8 exalogiccn01 EL-C 192.168.10.11 0000 00:14:4F:FA:DC:57 3404 0x8008 0A-ETH-3
31 WAIT-IOA N FC1FFE30C0661BAC 0000 00:14:4F:FB:80:0B 3408 0x800d 0A-ETH-3
11 WAIT-IOA N 691258B91BC2D1B3 0000 00:14:4F:FA:40:EA 3406 0x800b 0A-ETH-3
5 UP N F2162C51FC8BDABB exalogiccn06 EL-C 192.168.10.16 0000 00:14:4F:F9:FB:45 3405 0x800a 0A-ETH-3
13 UP N F8CCA25CB59E04C4 exalogiccn08 EL-C 192.168.10.18 0000 00:14:4F:FA:8B:E0 3405 0x800a 0A-ETH-3
16 WAIT-IOA N D68B860E22D5BAC4 exalogiccn08 EL-C 192.168.10.18 0000 00:14:4F:FB:5B:A6 3404 0x8008 0A-ETH-3
8 UP N 43953A42AEABD4CC exalogiccn05 EL-C 192.168.10.15 0000 00:14:4F:F8:6A:F1 3404 0x8008 0A-ETH-3
45 UP N 2B816771C46632D8 exalogiccn03 EL-C 192.168.10.13 0000 00:14:4F:F9:64:8A 3404 0x8008 0A-ETH-3
27 WAIT-IOA N A2496E6DBA0AA7FC exalogiccn08 EL-C 192.168.10.18 0000 00:14:4F:FB:55:63 3408 0x800d 0A-ETH-3
24 WAIT-IOA N 4B3D06069FB41A34 0000 00:14:4F:FA:D9:56 3408 0x800d 0A-ETH-4
32 WAIT-IOA N 52D42DEFE0A2643F 0000 00:14:4F:F9:BE:26 3408 0x800d 0A-ETH-4
9 UP N B38E31992FAE1F55 exalogiccn02 EL-C 192.168.10.12 0000 00:14:4F:F8:DF:C9 3405 0x800a 0A-ETH-4
55 UP N 4DFE2EBB5D18AD5C exalogiccn01 EL-C 192.168.10.11 0000 00:14:4F:FB:CC:5B 3404 0x8008 0A-ETH-4
42 UP N 21BF49A156343E6E exalogiccn07 EL-C 192.168.10.17 0000 00:14:4F:FA:B0:5B 3404 0x8008 0A-ETH-4
12 WAIT-IOA N D58F212817941073 0000 00:14:4F:FA:0B:F3 3406 0x800b 0A-ETH-4
38 WAIT-IOA N 53A509AF2F80B5C0 exalogiccn08 EL-C 192.168.10.18 0000 00:14:4F:FB:76:43 3404 0x8008 0A-ETH-4
14 UP N E750E2CAB30D50C5 exalogiccn08 EL-C 192.168.10.18 0000 00:14:4F:FB:C4:06 3405 0x800a 0A-ETH-4
46 UP N 34A8628E2919F5CA exalogiccn02 EL-C 192.168.10.12 0000 00:14:4F:F9:8A:A2 3405 0x800a 0A-ETH-4
18 WAIT-IOA N 8E30A327AF2C1BD1 0000 00:14:4F:FB:13:65 3404 0x8008 0A-ETH-4
50 UP N FC7A8398B4AA1CD1 exalogiccn04 EL-C 192.168.10.14 0000 00:14:4F:FA:04:45 3405 0x800a 0A-ETH-4
36 WAIT-IOA N 663D902D975B74D8 0000 00:14:4F:FB:1B:26 3408 0x800d 0A-ETH-4
6 UP N E2ACE4E494C225DA exalogiccn07 EL-C 192.168.10.17 0000 00:14:4F:FA:5D:AC 3405 0x800a 0A-ETH-4
20 WAIT-IOA N 5148FBF2521282E3 0000 00:14:4F:FB:51:D1 3408 0x800d 0A-ETH-4
28 WAIT-IOA N A1805B59D4BFC9F6 0000 00:14:4F:F9:3F:A9 3408 0x800d 0A-ETH-4
[root@exalogicgw02 ~]#
[root@exalogicgw02 ~]# setsmpriority list
Current SM settings:
smpriority 5
controlled_handover TRUE
subnet_prefix 0xfe80000000000000
M_Key None
Routing engine FatTree
[root@exalogicgw02 ~]# fwverify

Checking all present packages:
................................................................................................................................................................................................................................................. OK

Checking if any packages are missing:
................................................................................................................................................................................................................................................ OK

Verifying installed files:
.................................................................................................................................................................................................................................................... OK

Checking FW Coreswitch:
FW Version: 7.4.3002 OK
PSID: SUNX2826_I40_002 OK
Verifying image integrity OK

Checking FW Bridge-0:
FW Version: 8.6.2010 OK
PSID: SUNX2826_BX0_006 OK
Verifying image integrity OK

Checking FW Bridge-1:
FW Version: 8.6.2010 OK
PSID: SUNX2826_BX1_006 OK
Verifying image integrity OK

[root@exalogicgw02 ~]#

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback