Asset ID: 1-72-1576848.1
Update Date:2013-08-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  1576848.1 :   New fan installed in Infiniband gateway switch runs faster  


Related Items
  • Sun Network QDR InfiniBand Gateway Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  


Installation of a new fan module into the Infiniband Gateway Switch will run faster than the fans that's already installed.

In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-7661095281>

Applies to:

Sun Network QDR InfiniBand Gateway Switch - Version Not Applicable and later
Information in this document applies to any platform.

Symptoms

The speed of the newly installed fan is found to be different from that of the other fan already installled.

Changes

 Installation of new fan module.

Cause

  Installation of new fan module.

Solution

This is not an issue. There are  two different fans qualified for the Gateway switch, they are running at different fans speeds. This is fully supported, tested and qualified config. The two fans have slightly different performance and will run at different speeds.