Solution Type Problem Resolution Sure Solution 2187802.1 : Infiniband Switch - Firmware Downgrade To 2.1.6 Fails With Error: Cannot proceed with downgrade on this SP.
In this Document
Created from <SR 3-13293765919> Applies to:Exalogic Elastic Cloud X4-2 Half Rack - Version X4 and laterSun Datacenter InfiniBand Switch 36 - Version All Versions to All Versions [Release All Releases] Sun Network QDR InfiniBand Gateway Switch - Version All Versions to All Versions [Release All Releases] Oracle Exadata Hardware - Version 11.2.3.1.1 and later Information in this document applies to any platform. SymptomsCannot downgrade IB switch (NM2-36P or NM2-GW) firmware from v2.1.7-2 or newer to v2.1.6-2 or older. You receive the following error in the /tmp/fw_upgrade_pre_check.err file: Cannot proceed with downgrade on this SP. ChangesNewer Hardware CauseNewer IB switch hardware requires a newer firmware-kernel that is only available in IB switch firmware v2.1.7-2 or newer. SolutionThe following Infiniband switches with these P/N's require IB switch firmware v2.1.7-2 or newer:
NOTE - This is particularly important in the case of Oracle Engineered Systems, since customer needs to keep the IB Switch firmware revision in lockstep with their Engineered Systems PSU patch levels. For example only, with Exalogic, the IB Switch firmware 2.1.6 is used prior to their "April 2016 PSU" for Exalogic Infrastructure. For Exalogic, refer to <Document 1530781.1> Exalogic Infrastructure Physical and Virtual Releases/PSUs – Software and Firmware Version Information. Over time, as more customers upgrade their PSU to post-April-2016 versions, this will become less of an issue. For other Engineered System, refer to the relevant PSU for Infrastructure README/KB-articles.
Attachments This solution has no attachment |
||||||||||||||||||||
|