Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2353380.1
Update Date:2018-03-12
Keywords:

Solution Type  Problem Resolution Sure

Solution  2353380.1 :   root filesystem of Infiniband Switch reached to 94%  


Related Items
  • Sun Datacenter InfiniBand Switch 36
  •  
  • Sun Network QDR InfiniBand Gateway Switch
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Infiniband
  •  




In this Document
Symptoms
Changes
Cause
  
Solution


Created from <SR 3-16688276041>

Applies to:

Sun Datacenter InfiniBand Switch 36 - Version All Versions and later
Sun Network QDR InfiniBand Gateway Switch - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 root filesystem of Infiniband Switch reaches 94%

Changes

 After upgrading to firmware version 2.2.X, the Infiniband Switch root filesystem reaches to ~94% - 95%

Cause

With firmware versions 2.2.x the Sun Datacenter InfiniBand Switch 36 and Sun Network QDR InfiniBand Gateway Switch, the firmware has moved to Oracle Linux 6 as the base OS (from CentOS 5.2 for firmware 2.1.x and earlier), and the new OS uses more space than the older. This said, configuration and logs are on other partitions of the SSD, so the root partition will not grow.

This change can be verified in Read Me file for the Patch "Moved From CentOS 5.2 to Oracle Linux 6.5 with UEK2" under Changes from version 2.1.8."

 

Example:

Before Infiniband Switch Upgrade

[root@ib_hostname ~]# version
SUN DCS 36p version: 2.1.7-2 <======================
Build time: May 27 2015 11:14:46
SP board info:
Manufacturing Date: N/A
Serial Number: "NED8T0323"
Hardware Revision: 0x0100
Firmware Revision: 0x0046
BIOS version: NUP1R918
BIOS date: 01/19/2016

[root@ib_hostname ~]# df -k
Filesystem  1K-blocks    Used      Available  Use%  Mounted on
/dev/sda2    482152    271345    186308     60%     /            <======================
tmpfs          508704           24     508680      1%     /dev/shm
tmpfs          508704         972     507732      1%     /tmp

 

After Infiniband Switch Upgrade

[root@ib_hostname ~]# version
SUN DCS 36p version: 2.2.7-1 <======================
Build time: Aug 4 2017 12:20:53
SP board info:
Manufacturing Date: 2012.09.07
Serial Number: "NCDA11844"
Hardware Revision: 0x0007
Firmware Revision: 0x0000
BIOS version: SUN0R100
BIOS date: 06/22/2010

[root@ib_hostname ~]# df -k
Filesystem   1K-blocks       Used     Available   Use%  Mounted on
/dev/sda5      427156     387825       26100     94%     /           <======================
tmpfs            252704          252      252452      1%     /dev/shm
/dev/sda3       15863         3734       11310     25%    /var/log
/dev/sda2       15863         1677       13367     12%    /config
tmpfs            252704        1232     251472      1%     /tmp
 

Solution

This is normal for version 2.2.X and above and not a problem.

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback