Problem Document
|
Synopsis
|
Last Modified Date
|
2001666.1 |
NETRA 1290 FATAL: PROM_PANIC[0x0]: ECC Error: Uncorrectable Error |
2018-03-05
|
1938097.1 |
NETRA 1290 : FAILED FAN |
2017-05-02
|
1916321.1 |
SunFire[TM] V1280, E2900 and Netra[TM] 1280, 1290 System Hang Occur And OS Disk Failed |
2017-10-11
|
1591230.1 |
Diagnosing iostat Hard Errors on SPARC Servers DVD ROM |
2018-02-15
|
1583559.1 |
Sun Fire [TM] V1280/E2900, Netra 1280/1290 system: unable to boot due to "ERROR: Fast Data Access MMU Miss" and/or "Fatal SCSI error at script address 148 Illegal instruction" |
2017-10-11
|
1580204.1 |
Sun Fire [TM] V1280/E2900, Netra 1280/1290: ATAPI timeout messages at boot |
2017-10-18
|
1524340.1 |
73GB, 146GB, and 300GB Firmware Upgrade to Prevent Disk Drive Failures in SPARC platforms. |
2018-05-09
|
1517892.1 |
Sun Fire[TM] V1280, E2900, Netra[TM] 1280, and 1290 Servers: IB_SSC fails POST and stuck in a Boot loop |
2017-10-11
|
1516187.1 |
"Eject" button does not work on internal DAT72 drive. |
2018-02-16
|
1456194.1 |
Sun Fire [TM] V1280/E2900, Netra 1280/1290 ( LW8/Amazon/Everglades ): net1 Onboard Interface fails on boot net1 and test net1 of interface |
2017-10-18
|
1453917.1 |
Sun Fire v1280/E2900 or Netra 1280/1290: lom>console command may return that Solaris is not active when Solaris is actually running |
2014-09-22
|
1399165.1 |
Sun Fire [TM] V1280/E2900, Netra 1280/1290: Troubleshooting LOM can't boot - PANIC No ID info + busyWait() timeout + MAC address 0:0:0:0:0:0 |
2017-11-14
|
1269395.1 |
Sun Fire[TM] V1280, E2900, Netra[TM] 1280, and 1290 Servers: IB_SSC fails POST after "Not enough memory" message |
2016-07-01
|
1269016.1 |
Sun Fire V1280, E2900 and Netra 1280, 1290: DC-DC convertor voltage failure. Voltage ramp timed out after 500 msec. |
2017-10-18
|
1019667.1 |
Sun Fire[TM] Server System Board (SB) voltage errors. |
2017-10-18
|
1017987.1 |
Response to error: SepromSegment(constructor): PE at 0x----: Invalid CRC observed=xxxxxxxx expected=yyyyyyyy |
2017-02-02
|
1017844.1 |
Sun[TM] Fire 3800/4800/4810/6800/E2900/E4900/E6900/V1280 and Netra[TM] 1280/1290 Server: I/O Board (IB) power supply failures. |
2017-02-02
|
1011054.1 |
Sun Fire[TM] v1280, E2900, 3800, 4800, 4810, 6800, E4900, E6900, and Netra 1280, 1290 Server: Missing/Improper Seeprom CPU Speed information. |
2017-02-02
|
1009696.1 |
"kstat -p" and "prtdiag -v" may give seemingly different PCI bus speeds for Dual Fast Ethernet and Dual SCSI PCI Adapters |
2017-03-29
|
1009648.1 |
Sun[TM] Fire 3800/4800/4810/6800/E2900/E4900/E6900/V1280 and Netra[TM] 1280/1290 Server: SepromContainer.writeOut: sun.serengeti.I2cException: verify error |
2017-02-02
|
1009008.1 |
Sun Fire[TM] 3800, 4800, 4810, 6800, E4900, E6900, V1280, E2900, Netra 1280, or 1290 server: NCPQ_TO workarounds |
2017-02-02
|
1007996.1 |
picld error after upgrading PCI IB_SCC IO Assembly to PCI+ IO Assembly |
2017-02-02
|
1006676.1 |
Sun Fire[TM] V1280, E2900, or Netra 1280, 1290: a Solaris[TM] shutdown followed by a lom poweroff and poweron sequence can cause an unplanned SC reset. |
2017-10-18
|
1005071.1 |
Sun Fire[TM] Servers (3800/4800/4810/6800/E4900/E6900): I2C communication problem |
2017-02-02
|
1005021.1 |
Sun Fire[TM] V1280/E2900/Netra[TM] 1280/1290 Server: Incorrect Firmware Upgrade Procedure Can Lead to Incompatible Firmware on System Boards |
2017-10-11
|
1005013.1 |
probe-scsi-all may fail without reset-all on all Sun[TM] Systems |
2017-03-29
|
1004868.1 |
SunFire[TM] V1280, E2900 and Netra[TM] 1280, 1290: Lights Out Management (LOM) packages are missing |
2017-02-02
|
1004679.1 |
Sun Fire[TM] Servers: setdefaults does not reset local-mac-address? parameter |
2017-10-18
|
1004364.1 |
Sun Fire[TM] Midrange Server: Safari Port Error may be caused by a resetting SC |
2017-02-02
|
1003661.1 |
How to recover when a Sun Fire[TM]E2900, V1280 or Netra[TM] 1280 has an incompatible RTOS and ScApp |
2017-10-11
|