![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1006676.1 : Sun Fire[TM] V1280, E2900, or Netra 1280, 1290: a Solaris[TM] shutdown followed by a lom poweroff and poweron sequence can cause an unplanned SC reset.
PreviouslyPublishedAs 209307 Applies to:Sun Netra 1280 Server - Version Not Applicable and laterSun Fire V1280 Server - Version Not Applicable and later Sun Fire E2900 Server - Version Not Applicable and later Sun Netra 1290 Server - Version Not Applicable and later All Platforms SymptomsSystem Controller (SC) reset could occur unexpectedly. CauseThe behavior appears something like the following:
lom> poweron/N0/PS0: powered on Sat Apr 15 10:21:00 tkxhst21-sc lom: SysEvent 5 /N0/PS0, power state, On (5,1) /N0/PS1: powered on Sat Apr 15 10:21:01 tkxhst21-sc lom: SysEvent 5 /N0/PS1, power state, On (5,1) /N0/PS2: powered on Sat Apr 15 10:21:02 tkxhst21-sc lom: SysEvent 5 /N0/PS2, power state, On (5,1) /N0/PS3: powered on Sat Apr 15 10:21:03 tkxhst21-sc lom: SysEvent 5 /N0/PS3, power state, On (5,1) /N0/FT0: powered on Powering boards on ... Solution
lom> poweroff lom> resetsc < lom> poweron Executing resetsc will free up SC resources and place it in a "known" state. The poweron command will then power on all boards without any issues.
The unplanned SC reset is harmless and the subsequent execution of POST usually results in all boards passing without any issues. The SC is capable of resetting itself when necessary, but to avoid the inconvenience of running POST on all system boards (and any delays as a result), run resetsc before powering on all components and save yourself some time and hassle of worrying if there is a problem.
To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in an appropriate