![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1007996.1 : picld error after upgrading PCI IB_SCC IO Assembly to PCI+ IO Assembly
PreviouslyPublishedAs 211030 Applies to:Sun Fire E2900 Server - Version Not Applicable and laterSun Fire V1280 Server - Version Not Applicable and later Sun Netra 1290 Server - Version Not Applicable and later Sun Netra 1280 Server - Version Not Applicable and later All Platforms SymptomsDuring OS bootup the following error is seen on the console : ChangesUpgrading PCI IB_SCC IO Assembly to PCI+ IO Assembly CauseThe above error is attributed to a bug in the "picld". SolutionAdditional Information The above error is seen only in Solaris[TM] 9 Update 8 / Solaris[TM} 9 9/05. This issue is not seen in Solaris[TM] 8 or Solaris[TM] 10 releases required to support the PCI+ IB_SSC assembly The error message is seen in S9 with KJP Patch ID 118558-14 and above, but the underlying bug exists even prior to the Patch ID 118558-14, except that the warning message did not get printed on console.
Resolution This issue is fixed in S9 KJP 118558-29 or higher.
The bug for this issue is Bug ID 6427498 .
Attachments This solution has no attachment |
||||||||||||
|